Verified by manufacturer 6 months ago
EPD
Certificate type
Manually operated centre-pivot timber roof window. Suitable for roof pitches from 15-90°.
For roof pitches between 15–90°.
Features and benefits:
Glazing:
- Code 68:
- Code 62:
- Code 66:
- Code 70:
- Code 70Q:
Energy efficiency installation collars:
Flashing:
Flashings are available in materials and finishes to match roof window cladding.
Color | White Grey |
Finish | Painted Lacquered |
Material | Pine Guidance for specification option: Frames Aluminium Guidance for specification option: Cladding Glass |
Shape | Rectangle |
Width | 472 mm 550 mm 660 mm 780 mm 942 mm |
Height | 698 mm 778 mm 978 mm 1178 mm 1398 mm |
Warranty description | Ten year Guidance for specification option: For window and pane Three year Guidance for specification option: For blinds and electrics |
Uniclass | |
CAWS | L10/480 Roof windows |
Product range |
Product performance | |
Whole window U-value | 0.86–1.3 W/m²K.Guidance for specification option: Depending on product option. |
Glazing or infill | |
Composition | Argon filled cavity, Krypton filled cavity depending on product option. |
Hardware | Flashings are available in materials and finishes to match roof window cladding. |
Operation | |
Type | Manual operation via a control bar along the top of the sash. The sash can be parked in any position up to the horizontal, however the sash can also be fully rotated to allow for ease of cleaning of the outer pane. |
Accessories | None.Opening restrictor lock with key.Guidance for specification option: ZOZ 010KC S011 Security lock.Guidance for specification option: ZOZ 012K1 |
Execution | Fixing of wood frames. |
Internal frame and sash | White painted. Guidance for specification option: Code 2 Lacquered Pine. Guidance for specification option: Code 3 |
External cladding | Grey aluminium; colour reference NCS S-7500-N. Guidance for specification option: Code 0 Untreated copper. Guidance for specification option: Code 1 Titanium zinc. Guidance for specification option: Code 3 Painted aluminium. Guidance for specification option: Code 8, colour |
Roof pitch | Guidance for specification option: Insert requirements. |
Window code | GGL CK02. Guidance for specification option: Standard size 550 mm wide x 778 mm high; effective daylight area, 0.22 m². GGL CK04. Guidance for specification option: Standard size 550 mm wide x 978 mm high; effective daylight area, 0.29 m². GGL CK06. Guidance for specification option: Standard size 550 mm wide x 1178 mm high; effective daylight area, 0.37 m². GGL FK06. Guidance for specification option: Standard size 660 mm wide x 1178 mm high; effective daylight area, 0.47 m². GGL MK04. Guidance for specification option: Standard size 780 mm wide x 978 mm high; effective daylight area, 0.47 m². |
Glazing | 68. Guidance for specification option: 6.8 mm laminated inner pane with low-e coating; 12 mm Argon filled cavity; 3 mm heat strengthened mid pane with low-e coating; 12 mm Argon filled cavity; 4 mm toughened outer pane with easy to clean and low-e coatings. 62. Guidance for specification option: 6.8 mm laminated inner pane with low-e coating; 10 mm Krypton filled cavity; 3 mm heat strengthened mid pane with low-e coating; 10 mm Krypton filled cavity; 8 mm toughened outer pane with anti-dew coating. 66. Guidance for specification option: 6.8 mm laminated inner pane with low-e coating; 12 mm Krypton filled cavity; 3 mm heat strengthened mid pane with low-e coating; 12 mm Krypton filled cavity; 4 mm toughened outer pane with easy to clean and anti-dew coatings. 70. Guidance for specification option: 6.8 mm laminated inner pane with low-e coating; 15 mm Argon filled cavity; 4 mm toughened outer pane. 70Q. Guidance for specification option: 6.8 mm laminated inner pane with low-e coating; 16 mm Argon filled cavity; 4 mm toughened outer pane. |
Type | Not required. Blackout blind – Code DKL. Blackout energy blind – Code FHC. Duo blackout blind – Code DFD. External awning blind – Code MHL. |
Colour | Not applicable. As schedule. Guidance for specification option: Refer VELUX Blinds and Shutters brochure for available colours and patterns. |
Operation | Electric. Manual – Codes ZCT 200 and ZOZ 085. Guidance for specification option: Control rod and adaptor. |
Energy efficiency installation collars | Insulation collar – Code BDX 2000. Guidance for specification option: Not compatible with EDN and EDJ flashings. Includes BFX. Insulation collar – Code BDX 2000F. Guidance for specification option: Compatible with EDN and EDJ flashings only. Includes BFX. Underfelt collar – Code BFX 1000. Vapour barrier collar – Code BBX 0000. |
Flashing | EDL. Guidance for specification option: For standard installation in slate up to 8 mm thick; roof pitch 15–90°. EDN. Guidance for specification option: For recessed installation in slate up to 8 mm thick; roof pitch 20–90°. EDW. Guidance for specification option: For standard installation in tiles up to 120 mm in profile; roof pitch 15–90°. Also for interlocking slate, thatch and profile sheeting. EDJ. Guidance for specification option: For recessed installation in tile up to 90 mm in profile; roof pitch 20–90°. EDP. Guidance for specification option: For standard installation in plain tiles up to 14 mm thick; roof pitch 25–90°. |
Contains Red List materials | Yes |
Country of material origin | Europe |
Country of product manufacture | Europe |
Material | Pine Guidance for specification option: Frames Aluminium Guidance for specification option: Cladding Glass |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 1.7 kg CO₂ eq/unit |
Recyclability | Yes |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 12 % |
Expected Life | 30 year |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 4 |