GGU Manually operated centre-pivot white polyurethane roof window. Suitable for roof pitches from 15-90°.
For roof pitches between 15–90°.
Features and benefits:
Glazing:
- Code 68:
- Code 62:
- Code 66:
- Code 70:
- Code 70Q:
Energy efficiency installation collars:
Flashing:
Flashings are available in materials and finishes to match roof window cladding.
Color | White |
Material | Timber Guidance for specification option: Timber core Polyurethane Guidance for specification option: Polyurethane coated frames Aluminium Guidance for specification option: Aluminium cladding Glass Manufacturer guidanceInternal frame and sash is a white polyurethane – Code 0 finish around a timber core. External cladding is available in grey aluminium; colour reference NCS S-7500-N - Code 0, untreated copper – Code 1, titanium zinc – Code 3 and painted aluminium – Code 8. |
Width | 550 mm 660 mm 780 mm 942 mm 1140 mm |
Height | 778 mm 978 mm 1178 mm 1398 mm 1600 mm |
Warranty description | Ten year Guidance for specification option: For window and pane Three year Guidance for specification option: For electrical items and blinds |
Uniclass | |
CAWS | L10/480 Roof windows |
Product range |
Standard | BBA Agrément Certificate. |
Product performance | |
Whole window U-value | 0.83–1.3 W/m²K.Guidance for specification option: Depending on product option. |
Glazing or infill | |
Composition | Argon filled cavity or Krypton filled cavity depending on product option. |
Hardware | Flashings are available in materials and finishes to match roof window cladding. |
Operation | |
Type | Manually operated.Guidance for specification option: One pull of top control bar allows background ventilation whilst the window remains securely closed. One further pull opens the window. Rotates 180° and locks in place for easy cleaning of outer pane |
Fixing features | Insulation collar, underfelt collar and vapour barrier collar available for installation. |
Accessories | None.Opening restrictor lock.Guidance for specification option: ZOZ 010KC S011 - Includes key. Window lock.Guidance for specification option: ZOZ 012K1 |
Execution | Fixing of plastics frames. |
Internal frame and sash | White polyurethane. Guidance for specification option: Code 0 |
External cladding | Grey aluminium; colour reference NCS S-7500-N. Guidance for specification option: Code 0 Untreated copper. Guidance for specification option: Code 1 Titanium zinc. Guidance for specification option: Code 3 Painted aluminium. Guidance for specification option: code 8 – colour |
Roof pitch | Guidance for specification option: Insert requirements. |
Window code | GGU CK02. Guidance for specification option: Standard size 550 mm wide x 778 mm high, effective daylight area 0.22 m². GGU CK04. Guidance for specification option: Standard size 550 mm wide x 978 mm high, effective daylight area 0.29 m². GGU CK06. Guidance for specification option: Standard size 550 mm wide x 1178 mm high, effective daylight area 0.37 m². GGU FK06. Guidance for specification option: Standard size 660 mm wide x 1178 mm high, effective daylight area 0.47 m². GGU MK04. Guidance for specification option: Standard size 780 mm wide x 978 mm high, effective daylight area 0.47 m². |
Glazing | 68. Guidance for specification option: 6.8 mm laminated inner pane with low-e coating; 12 mm Argon filled cavity; 3 mm heat strengthened mid pane with low-e coating; 12 mm Argon filled cavity; 4 mm toughened outer pane with easy to clean and low-e coatings. 62. Guidance for specification option: 6.8 mm laminated inner pane with low-e coating; 10 mm Krypton filled cavity; 3 mm heat strengthened mid pane with low-e coating; 10 mm Krypton filled cavity; 8 mm toughened outer pane with anti-dew coating. 66. Guidance for specification option: 6.8 mm laminated inner pane with low-e coating; 12 mm Krypton filled cavity; 3 mm heat strengthened mid pane with low-e coating; 12 mm Krypton filled cavity; 4 mm toughened outer pane with easy to clean and anti-dew coatings. 70. Guidance for specification option: 6.8 mm laminated inner pane with low-e coating; 15 mm Argon filled cavity; 4 mm toughened outer pane. 70Q. Guidance for specification option: 6.8 mm laminated inner pane with low-e coating; 16 mm Argon filled cavity; 4 mm toughened outer pane. |
Type | Blackout blind – Code DKL. Blackout energy blind – Code FHC. Duo blackout blind – Code DFD. External awning blind – Code MHL. External roller shutter – Code SHL. |
Colour | Not applicable. As schedule. Guidance for specification option: Refer to VELUX Blinds and Shutters brochure for available colours and patterns. |
Operation | Not required. Manual. Guidance for specification option: Codes ZCT 200K and ZOZ 085 - Control rod and blind adaptor. |
Energy efficiency installation collars | Insulation Collar – Code BDX 2000. Guidance for specification option: Not compatible with EDN and EDJ flashings. Includes BFX. Insulation Collar – Code BDX 2000F. Guidance for specification option: Compatible with EDN and EDJ flashings only. Includes BFX. Underfelt Collar – Code BFX 1000. Vapour Barrier Collar – Code BBX 0000. |
Flashing | EDL. Guidance for specification option: For standard installation in slate up to 8 mm thick; roof pitch 15–90°. EDN. Guidance for specification option: For recessed installation in slate up to 8 mm thick; roof pitch 20–90°. EDW. Guidance for specification option: For standard installation in tiles up to 120 mm in profile; roof pitch 15–90°. Also for interlocking slate, thatch and profile sheeting. EDJ. Guidance for specification option: For recessed installation in tile up to 90 mm in profile; roof pitch 20–90°. EDP. Guidance for specification option: For standard installation in plain tiles up to 14 mm thick; roof pitch 25–90°. |
Contains Red List materials | Yes |
Country of material origin | Europe |
Country of product manufacture | Europe |
Material | Timber Guidance for specification option: Timber core Polyurethane Guidance for specification option: Polyurethane coated frames Aluminium Guidance for specification option: Aluminium cladding Glass Manufacturer guidanceInternal frame and sash is a white polyurethane – Code 0 finish around a timber core. External cladding is available in grey aluminium; colour reference NCS S-7500-N - Code 0, untreated copper – Code 1, titanium zinc – Code 3 and painted aluminium – Code 8. |
Manufacturing plant location | |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 2.7 kg CO₂ eq/unit |
Recyclability | Yes |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 12 % |
Expected Life | 30 year |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 4 |