Verified by manufacturer 1 month ago
EPD
Certificate type
GGU Manually operated centre-pivot white polyurethane roof window. Suitable for roof pitches from 15-90°.
For roof pitches between 15–90°.
Features and benefits:
Glazing:
- Code 68:
- Code 62:
- Code 66:
- Code 70:
- Code 70Q:
Energy efficiency installation collars:
Flashing:
Flashings are available in materials and finishes to match roof window cladding.
Color | White |
Material | Timber Guidance for specification option: Timber core Polyurethane Guidance for specification option: Polyurethane coated frames Aluminium Guidance for specification option: Aluminium cladding Glass Manufacturer guidanceInternal frame and sash is a white polyurethane – Code 0 finish around a timber core. External cladding is available in grey aluminium; colour reference NCS S-7500-N - Code 0, untreated copper – Code 1, titanium zinc – Code 3 and painted aluminium – Code 8. |
Width | 550 mm 660 mm 780 mm 942 mm 1140 mm |
Height | 778 mm 978 mm 1178 mm 1398 mm 1600 mm |
Warranty description | Ten year Guidance for specification option: For window and pane Three year Guidance for specification option: For electrical items and blinds |
Uniclass | |
CAWS | L10/480 Roof windows |
Product range |
Standard | BBA Agrément Certificate. |
Product performance | |
Whole window U-value | 0.83–1.3 W/m²K.Guidance for specification option: Depending on product option. |
Glazing or infill | |
Composition | Argon filled cavity or Krypton filled cavity depending on product option. |
Hardware | Flashings are available in materials and finishes to match roof window cladding. |
Operation | |
Type | Manually operated.Guidance for specification option: One pull of top control bar allows background ventilation whilst the window remains securely closed. One further pull opens the window. Rotates 180° and locks in place for easy cleaning of outer pane |
Fixing features | Insulation collar, underfelt collar and vapour barrier collar available for installation. |
Accessories | None.Opening restrictor lock.Guidance for specification option: ZOZ 010KC S011 - Includes key. Window lock.Guidance for specification option: ZOZ 012K1 |
Execution | Fixing of plastics frames. |
Internal frame and sash | White polyurethane. Guidance for specification option: Code 0 |
External cladding | Grey aluminium; colour reference NCS S-7500-N. Guidance for specification option: Code 0 Untreated copper. Guidance for specification option: Code 1 Titanium zinc. Guidance for specification option: Code 3 Painted aluminium. Guidance for specification option: code 8 – colour |
Roof pitch | Guidance for specification option: Insert requirements. |
Window code | GGU CK02. Guidance for specification option: Standard size 550 mm wide x 778 mm high, effective daylight area 0.22 m². GGU CK04. Guidance for specification option: Standard size 550 mm wide x 978 mm high, effective daylight area 0.29 m². GGU CK06. Guidance for specification option: Standard size 550 mm wide x 1178 mm high, effective daylight area 0.37 m². GGU FK06. Guidance for specification option: Standard size 660 mm wide x 1178 mm high, effective daylight area 0.47 m². GGU MK04. Guidance for specification option: Standard size 780 mm wide x 978 mm high, effective daylight area 0.47 m². |
Glazing | 68. Guidance for specification option: 6.8 mm laminated inner pane with low-e coating; 12 mm Argon filled cavity; 3 mm heat strengthened mid pane with low-e coating; 12 mm Argon filled cavity; 4 mm toughened outer pane with easy to clean and low-e coatings. 62. Guidance for specification option: 6.8 mm laminated inner pane with low-e coating; 10 mm Krypton filled cavity; 3 mm heat strengthened mid pane with low-e coating; 10 mm Krypton filled cavity; 8 mm toughened outer pane with anti-dew coating. 66. Guidance for specification option: 6.8 mm laminated inner pane with low-e coating; 12 mm Krypton filled cavity; 3 mm heat strengthened mid pane with low-e coating; 12 mm Krypton filled cavity; 4 mm toughened outer pane with easy to clean and anti-dew coatings. 70. Guidance for specification option: 6.8 mm laminated inner pane with low-e coating; 15 mm Argon filled cavity; 4 mm toughened outer pane. 70Q. Guidance for specification option: 6.8 mm laminated inner pane with low-e coating; 16 mm Argon filled cavity; 4 mm toughened outer pane. |
Type | Blackout blind – Code DKL. Blackout energy blind – Code FHC. Duo blackout blind – Code DFD. External awning blind – Code MHL. External roller shutter – Code SHL. |
Colour | Not applicable. As schedule. Guidance for specification option: Refer to VELUX Blinds and Shutters brochure for available colours and patterns. |
Operation | Not required. Manual. Guidance for specification option: Codes ZCT 200K and ZOZ 085 - Control rod and blind adaptor. |
Energy efficiency installation collars | Insulation Collar – Code BDX 2000. Guidance for specification option: Not compatible with EDN and EDJ flashings. Includes BFX. Insulation Collar – Code BDX 2000F. Guidance for specification option: Compatible with EDN and EDJ flashings only. Includes BFX. Underfelt Collar – Code BFX 1000. Vapour Barrier Collar – Code BBX 0000. |
Flashing | EDL. Guidance for specification option: For standard installation in slate up to 8 mm thick; roof pitch 15–90°. EDN. Guidance for specification option: For recessed installation in slate up to 8 mm thick; roof pitch 20–90°. EDW. Guidance for specification option: For standard installation in tiles up to 120 mm in profile; roof pitch 15–90°. Also for interlocking slate, thatch and profile sheeting. EDJ. Guidance for specification option: For recessed installation in tile up to 90 mm in profile; roof pitch 20–90°. EDP. Guidance for specification option: For standard installation in plain tiles up to 14 mm thick; roof pitch 25–90°. |
Contains Red List materials | Yes |
Country of material origin | Europe |
Country of product manufacture | Europe |
Material | Timber Guidance for specification option: Timber core Polyurethane Guidance for specification option: Polyurethane coated frames Aluminium Guidance for specification option: Aluminium cladding Glass Manufacturer guidanceInternal frame and sash is a white polyurethane – Code 0 finish around a timber core. External cladding is available in grey aluminium; colour reference NCS S-7500-N - Code 0, untreated copper – Code 1, titanium zinc – Code 3 and painted aluminium – Code 8. |
Manufacturing plant location | |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 2.7 kg CO₂ eq/unit Certified Lower emissions |
Recyclability | Yes |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 12 % |
Expected Life | 30 year |
Certified
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 4 |