Glidevale Protect Wunderlay® - Impermeable Roofing Underlay

Verified by manufacturer 4 months ago

1500 mm-wide rolls

BPD Building Product Design Ltd Variant:
Third party certifications:
  • BM Trada

    BM Trada

    Certificate type

Heavy-duty type HR impermeable roofing underlay, designed for all cold and warm pitched roofs.

Jump to:
+44 (0)161 905 5700 Website

Application

The product can be used for all pitched roof constructions (tiled and slated), whether the insulation is at ceiling joist level or at rafter level.


Description

Protect Wunderlay is a heavy-duty type HR roofing underlay, designed for all cold and warm pitched roofs in conjunction with the provision of ventilation at eaves and ridge. The product can be used with a well-sealed ceiling and a separate air and vapour control layer on the warm side of the insulation or where the ceiling is not well-sealed as in a re-roofing application.


Features and benefits:

  • Completely water and airtight.
  • UV and heat resistant.
  • Good nail tear and tensile strength for its weight.
  • Does not generate nuisance noise under wind loading.
  • CE marked and BM TRADA certified.
  • Absorbent under surface prevents condensate drip off.
  • Embossed dark grey upper surface reduces glare and takes a chalk line marking.
  • Easy to cut and handle.
  • Achieves Zones 1-4 at 345 mm batten gauge (1367Pa), when tested to Annex A of BS 5534, ensuring wide coverage across the UK and throughout Ireland
  • Achieves Zones 1-5 at 310 mm batten gauge (2145 Pa).
  • Developed to overcome the disadvantages of traditional Type 1F and 5U felts and second generation plastic sheet materials.
  • Provides a secondary line of defence against wind-driven rain and snow and resistance to wind uplift.

General information

Color

Grey

Finish

Embossed

Material

Polypropylene

Shape

Rectangle

Guidance for specification option:

Supplied as a Roll

Length

30000 mm

Guidance for specification option:

1500 mm widths only.

45000 mm

Guidance for specification option:

1000 mm widths only.

Width

1000 mm

1500 mm

Uniclass

Pr_25_57_65_60 Plastics sheetsPrimary

CAWS

H60/120 Concrete roof tiling

H60/105 Clay roof tiling

H61/105 Roof slating

H62/125 Roof slating

H62/105 Roof slating

H62/145 Roof slating

H64/110 Wood shingle/ shake roofing

H65/105 Clay roof tiling

H65/115 Concrete roof tiling

H65/135 Ceramic slate roof tiling

H65/125 Reconstituted slate roof tiling

H67/110 Metal roof tiling

H61/5 Roof slating

H60/3 Roof tiling

H62/3 Roof slating

H67/5 Metal roof tiling

H65/5 Roof tiling

H64/10 Wood shingle/ shake roofing

H65/10 Reconstituted slate roof tiling

Product range

Impermeable Underlays

Specification data - Plastics sheets

Material

Polypropylene.

Purpose

Roofing underlay (impermeable).

Standard

BS EN 13859-1, BS 5250, BS 5534, NHBC STANDARDS.

Performance characteristics

-

Tensile strength (minimum)

Manufacturer's standard.

Guidance for specification option:

Machine direction (along roll):

  • 233 N/50 mm: Unaged tensile strength to BS EN 12311-1 with mods.
  • 231 N/50 mm: Aged tensile strength to BS EN 12311-1 with mods.

Cross direction (across roll):

  • 246 N/50 mm: Unaged tensile strength to BS EN 12311-1 with mods.
  • 206 N/50 mm: Aged tensile strength to BS EN 12311-1 with mods.

Tear resistance

Manufacturer's standard.

Guidance for specification option:

  • 189 N: To BS EN 12310-1 with mods, along roll.
  • 199 N: To BS EN 12310-1 with mods, across roll..

UV stabilization

Manufacturer's standard.

Guidance for specification option:

UV and heat ageing conditions: UVA lamps at 50°C for 336 hours followed by heat ageing at 70°C for 90 days.

Third-party certification

BM TRADA Certified.

Form

Non-woven, spunbonded

Guidance for specification option:

Twin ply construction comprising of a polypropylene non-woven layer, coated on one surface with a continuous film of polypropylene / polyethylene blend.


Physical properties

-

Colour

Dark Grey.

Guidance for specification option:

Embossed dark grey. Printed with product branding for ease of identification.

Weight (minimum)

120 g/m².

Guidance for specification option:

6 kg per roll.

Dimensions

-

Thickness (minimum)

0.49 mm.

Width (minimum)

1500 mm.

Manufacturer guidance

45 m².

Roll length (minimum)

30 m.

Execution

-

Manufacturer guidance

Installed below the primary roof covering onto rafters or sarking board.

Roof space ventilation should be provided at both low and high level as with all impermeable (type HR) roofing underlays irrespective of insulation type or position. Please see our ventilation products on NBS or contact us for further information.

Flexibility at low temperature

-40°C.

Class (minimum)

W1

Guidance for specification option:

>2.0m hydrostatic head of water resistance


Manufacturer guidance

Resistance to water penetration to BS EN 1928


Wind resistance

Zones 1-4.

Guidance for specification option:

Wind uplift resistance (at 345 mm batten gauge) and 600 mm rafter centres - 1367 Pa.


Wind uplift resistance across the UK and Ireland - Zones 1-4 at 345 mm batten gauge to BS 5534.

Accessories

Glidevale Protect FV250.

Glidevale Protect SV609.

Glidevale Protect In-line vents.

Glidevale Protect G range vents.

Sustainability data

Contains Red List materials

No

Country of product manufacture

United Kingdom

Material

Polypropylene

BIM objects

Platform Compatible Version
Revit
-

1

Third party certifications

BM Trada

BM Trada

Protect Wunderlay BM TRADA Certificate No CPS-001

BM Trada

BM Trada

Protect Wunderlay BM TRADA Schedule No CPS-009

Literature

Glidevale Protect Wunderlay®

Glidevale Protect Wunderlay®

BS 5250:2021 Management of moisture in buildings

BS 5250:2021 Management of moisture in buildings

Building Healthy Solutions for Offsite

Building Healthy Solutions for Offsite

Similar products from BPD Building Product Design Ltd

Glidevale Protect A1 T3 Plus - Impermeable Roofing Underlay

Glidevale Protect A1 T3 Plus - Impermeable Roofing Underlay

Glidevale Protect A1® - Impermeable Roofing Underlay

Glidevale Protect A1® - Impermeable Roofing Underlay

Glidevale Protect Barriair AVCL - Vapour Control Layer

Glidevale Protect Barriair AVCL - Vapour Control Layer

Glidevale Protect VC Foil Ultra AVCL - Vapour Control Layer

Glidevale Protect VC Foil Ultra AVCL - Vapour Control Layer