Manually operated, top hung roof window for twin installation with 18 mm or 50 mm gap on roof pitches between 15–55° (75°).
For twin installation with 18 mm or 50 mm gap on roof pitches between 15–90°.
Features and benefits:
Glazing:
- Code 68:
- Code 66:
- Code 70:
Energy efficiency installation collars:
Flashing:
Flashings are available in materials and finishes to match roof window cladding.
- Code EBL 0021B:
For standard installation into slate and flat roofing materials up to 8 mm thick: not suitable for interlocking slate.
- Code EBW 0021B:
For standard installation into flat and profiled roofing materials up to 120 mm thick, including profiled sheeting and interlocking slates.
- Code EBP 0021B:
- Code EBL 0021C:
For CK02, CK04 and CK06 size windows only.
- Code EBW 0021C:
For CK02, CK04 and CK06 size windows only.
- Code ZWC:
Support rafters:
Supplied in the same finish as the roof windows.
Color | White |
Finish | Guidance for specification option: Internal frame and sash is a white polyurethane – Code 0 on timber core and external cladding available in grey aluminium; colour reference NCS S-7500-N - Code 0, Untreated copper – Code 1, Titanium zinc – Code 3, Painted aluminium – Code 8 |
Material | Pine Guidance for specification option: frames Aluminium Guidance for specification option: cladding |
Size | Manufacturer guidanceWide range of sizes to suit project requirements. Distance between side frames is 18 mm as standard or 50 mm |
Width | 18 mm 50 mm |
Warranty description | Ten year Guidance for specification option: For window and pane Three year Guidance for specification option: For electrical items and blinds |
Uniclass | |
CAWS | L10/480 Roof windows |
Standard | BBA Agrément Certificate. |
Product performance | |
Whole window U-value | 0.86–1.3 W/m²K.Guidance for specification option: Depending on product option. |
Glazing or infill | |
Composition | Argon filled cavity or Krypton filled cavity depending on product option. |
Hardware | Flashings are available in materials and finishes to match roof window cladding. |
Operation | |
Type | Manually operated - easy to open and quick to close with the top control bar. |
Fixing features | Insulation collar, underfelt collar and vapour barrier collar available for installation. |
Accessories | None.Locking handle.Guidance for specification option: Code 028321 |
Execution | Fixing of wood frames. |
Internal frame and sash | White painted. Guidance for specification option: Code 2 Lacquered natural pine. Guidance for specification option: Code 3 |
External cladding | Grey aluminium; colour reference NCS S-7500-N. Guidance for specification option: Code 0 Untreated copper. Guidance for specification option: Code 1 Titanium zinc. Guidance for specification option: Code 3 Painted aluminium. Guidance for specification option: Code 8, colour |
Roof pitch | Guidance for specification option: Insert requirements. |
Number of windows in group | Guidance for specification option: Insert requirements. |
Distance between side frames | 18 mm. Guidance for specification option: Standard frame gap. 50 mm. Guidance for specification option: CK02, CK04 and CK06 only. |
Support rafters | Not required. EBY W20 3000. Guidance for specification option: 2000 mm long. 18 mm frame gap only. EBY W27 3000. Guidance for specification option: 2700 mm long. 18 mm frame gap only. EBY W35 3000. Guidance for specification option: 3500 mm long. 18 mm frame gap only. |
Window code | GPL CK04. Guidance for specification option: Standard size 550 mm wide x 978 mm high, effective daylight area 0.29 m². GPL CK06. Guidance for specification option: Standard size 550 mm wide x 1178 mm high, effective daylight area 0.37 m². GPL FK06. Guidance for specification option: Standard size 660 mm wide x 1178 mm high, effective daylight area 0.47 m². GPL MK04. Guidance for specification option: Standard size 780 mm wide x 978 mm high, effective daylight area 0.47 m². GPL MK06. Guidance for specification option: Standard size 780 mm wide x 1178 mm high, effective daylight area 0.59 m². |
Glazing | 68. Guidance for specification option: 6.8 mm laminated inner pane with low-e coating; 12 mm Argon filled cavity; 3 mm heat strengthened mid pane with low-e coating; 12 mm Argon filled cavity; 4 mm toughened outer pane with easy to clean and low-e coatings. 66. Guidance for specification option: 6.8 mm laminated inner pane with low-e coating; 12 mm Krypton filled cavity; 3 mm heat strengthened mid pane with low-e coating; 12 mm Krypton filled cavity; 4 mm toughened outer pane with easy to clean and anti-dew coatings. 70. Guidance for specification option: 6.8 mm laminated inner pane with low-e coating; 15 mm Argon filled cavity; 4 mm toughened outer pane. |
Type | Not required. Blackout blind – Code DKL. Blackout energy blind – Code FHC. Duo blackout blind – Code DFD. External awning blind – Code MHL. |
Colour | Not applicable. As schedule. Guidance for specification option: Refer VELUX Blinds and Shutters brochure for available colours and patterns. |
Operation | Not applicable. Manual. |
Energy efficiency installation collars | Insulation Collar – Code BDX 2011. Guidance for specification option: Includes BFX, for 18 mm gap only. Underfelt Collar – Code BFX 1000. Vapour Barrier Collar – Code BBX 0000. |
Flashing | EBL 0021B. Guidance for specification option: 18 mm gap between units; for standard installation into slate up to 8 mm thick; roof pitch 15–90º. EBW 0021B. Guidance for specification option: 18 mm gap between units; for standard installation into tiles up to 120 mm in profile; roof pitch 15–90º. EBP 0021B. Guidance for specification option: 18 mm gap between units; for standard installation into plain tiles up to 14 mm thick; roof pitch 25–90º. EBL 0021C. Guidance for specification option: 50 mm gap between units; for standard installation into slate up to 8 mm thick; roof pitch 15–90°; CK02, CK04 and CK06 only. EBW 0021C. Guidance for specification option: 50 mm gap between units; for standard installation into tiles up to 120 mm in profile; roof pitch 15–90º; CK02, CK04 and CK06 only. |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 2.1 kg·CO₂e/kg Self declared |
GBL Low Pitch, Centre-Pivot Roof Window
GCL Heritage conservation roof window
GDL Roof Balcony
GEL Roof Terrace
GGL Centre-Pivot Roof Window
GGL Electric, Centre-Pivot Roof Window with GIL Sloping Fixed Window Below
GGL Electric, Centre-Pivot Roof Window, Combination Installation
GGL Electric, Centre-Pivot Roof Window, Twin Installation
GGL Electric, Centre-Pivot Roof Window, with GIL Sloping Fixed Windows Below, Combination Installation
GGL Electric/ Solar Centre-Pivot Roof Window