Verified by manufacturer 4 months ago
Manually operated, top hung roof window with additional lower fixed element on roof pitches between 15–55° (75°).
Can be installed in roof pitches 15–55° and up to 75° with special springs.
Features and benefits:
Glazing:
- Code 68:
- Code 66:
- Code 70:
Configuration:
Roof window and lower fixed window must be the same width.
Color | White |
Material | Pine Guidance for specification option: Frames Aluminium Guidance for specification option: Cladding Manufacturer guidanceInternal frame and sash is a white polyurethane – Code 0 on timber core and external cladding available in grey aluminium; colour reference NCS S-7500-N - Code 0, Untreated copper – Code 1, Titanium zinc – Code 3, Painted aluminium – Code 8. |
Size | Manufacturer guidanceWide range of sizes to suit project requirements |
Width | 780 mm 942 mm 1140 mm 1340 mm |
Height | 978 mm 1178 mm 1398 mm 1600 mm 920 mm |
Warranty description | Ten year Guidance for specification option: For window and pane Three year Guidance for specification option: For electrical items and blinds |
Uniclass | |
CAWS | L10/480 Roof windows |
Product performance | |
Whole window U-value | 1.0–1.3 W/m²K.Guidance for specification option: Depending on product option. |
Glazing or infill | |
Composition | Argon filled cavity or Krypton filled cavity depending on product option. |
Hardware | Flashings are available in materials and finishes to match roof window cladding. |
Operation | |
Type | Manually operated. |
Fixing features | Insulation collar, underfelt collar and vapour barrier collar available for installation. |
Accessories | None.Locking handle.Guidance for specification option: code 028321 |
Execution | Fixing of wood frames. |
Internal frame and sash | White painted. Guidance for specification option: Code 2 Lacquered natural pine. Guidance for specification option: Code 3 |
External cladding | Grey aluminium; colour reference NCS S-7500-N. Guidance for specification option: Code 0 Untreated copper. Guidance for specification option: Code 1 Titanium zinc. Guidance for specification option: Code 3 Painted aluminium. Guidance for specification option: Code 8, colour |
Roof pitch | Guidance for specification option: Insert requirements. |
Roof window code | GPL MK04. Guidance for specification option: Standard size 780 mm wide x 978 mm high, effective daylight area 0.47 m². GPL MK06. Guidance for specification option: Standard size 780 mm wide x 1178 mm high, effective daylight area 0.59 m². GPL MK08. Guidance for specification option: Standard size 780 mm wide x 1398 mm high, effective daylight area 0.72 m². GPL PK08. Guidance for specification option: Standard size 942 mm wide x 1398 mm high, effective daylight area 0.92 m². GPL PK10. Guidance for specification option: Standard size 942 mm wide x 1600 mm high, effective daylight area 1.07 m². |
Fixed lower window code | GIL MK34. Guidance for specification option: Standard size 780 mm wide x 920 mm high; effective daylight area 0.44 m². GIL PK34. Guidance for specification option: Standard size 942 mm wide x 920 mm high; effective daylight area 0.56 m². GIL SK34. Guidance for specification option: Non-standard size 1140 mm wide x 920 mm high; effective daylight area 0.70 m². GIL UK34. Guidance for specification option: Non-standard size 1340 mm wide x 920 mm high; effective daylight area 0.85 m². |
Glazing | 68. Guidance for specification option: 6.8 mm laminated inner pane with low-e coating; 12 mm Argon filled cavity; 3 mm heat strengthened mid pane with low-e coating; 12 mm Argon filled cavity; 4 mm toughened outer pane with easy to clean and low-e coatings. 66. Guidance for specification option: 6.8 mm laminated inner pane with low-e coating; 12 mm Krypton filled cavity; 3 mm heat strengthened mid pane with low-e coating; 12 mm Krypton filled cavity; 4 mm toughened outer pane with easy to clean and anti-dew coatings. 70. Guidance for specification option: 6.8 mm laminated inner pane with low-e coating; 15 mm Argon filled cavity; 4 mm toughened outer pane. |
Upper roof window | Blackout blind – Code DKL. Blackout energy blind – Code FHC. Duo blackout blind – Code DFD. Flying pleated blind – Code FHL. Roller blind – Code RFL. |
Lower fixed window | Not required. Blackout blind – Code DKL. Blackout energy blind – Code FHC. Duo blackout blind – Code DFD. Flying pleated blind – Code FHL. |
Energy efficient installation | Insulation Collar – Code BDX 2000. Guidance for specification option: Not compatible with E*N and E*J flashings. Includes BFX. Underfelt Collar – Code BFX 1000. Vapour Barrier Collar – Code BBX 0000. |
Flashing | EDL + ETL. Guidance for specification option: For standard installation into slate up to 8 mm thick; root pitch 15–90° EDW + ETW. Guidance for specification option: For standard installation into tiles up to 120 mm in profile; roof pitch 15–90°. Also for interlocking slate, thatch and profile sheeting. EDN + ETN. Guidance for specification option: For recessed installation into slate up to 8 mm thick; root pitch 20–90°. EDJ + ETJ. Guidance for specification option: For recessed installation into tile up to 120 mm thick; root pitch 20–90°. ZWC. Guidance for specification option: For standard installation where an on-site flashing is required; roof pitch 15–90°. |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 2.1 kg·CO₂e/kg Self declared |
GBL Low Pitch, Centre-Pivot Roof Window
GCL Heritage conservation roof window
GDL Roof Balcony
GEL Roof Terrace
GGL Centre-Pivot Roof Window
GGL Electric, Centre-Pivot Roof Window with GIL Sloping Fixed Window Below
GGL Electric, Centre-Pivot Roof Window, Combination Installation
GGL Electric, Centre-Pivot Roof Window, Twin Installation
GGL Electric, Centre-Pivot Roof Window, with GIL Sloping Fixed Windows Below, Combination Installation
GGL Electric/ Solar Centre-Pivot Roof Window