Verified by manufacturer 4 months ago
Manually operated top hung, roof window with additional vertical element on roof pitches between 15–55°.
For roof pitches between 15–55°. Suitable for one and a half-storey properties.
Features and benefits:
Glazing:
- Code 70:
6.8 mm laminated inner pane with low-e coating; 15 mm Argon filled cavity; 4 mm toughened outer pane.
Vertical window:
– Side hung, tilt and turn option (VFA and VFB):
– Bottom hung option (VFE):
Color | White Guidance for specification option: External Colour NCS S-7500-N; Internal Colour, white paint NCS S 0500-N |
Finish | Lacquered Guidance for specification option: Internal frame and sash is White painted as standard or comes in lacquered pine Painted |
Material | Pine Guidance for specification option: Pine frames Aluminium Guidance for specification option: Aluminium cladding. External cladding in grey aluminium; colour reference NCS S-7500-N - Code 0. |
Size | Manufacturer guidanceWide range of sizes to suit project requirements |
Width | 780 mm 942 mm 1140 mm 1340 mm |
Height | 978 mm 1178 mm 1398 mm 1600 mm 601 mm |
Warranty description | Ten year Guidance for specification option: For window and pane Three year Guidance for specification option: For electrical items and blinds |
Uniclass | |
CAWS | L10/480 Roof windows |
Product performance | |
Whole window U-value | 1.0–1.3 W/m²K.Guidance for specification option: Depending on product option. |
Glazing or infill | |
Composition | Argon filled cavity. |
Hardware | Flashings are available in materials and finishes to match roof window cladding. |
Operation | |
Type | Manually operated.Guidance for specification option: bottom handle for convenient opening of upper window, powerful gentle springs make it easy to open. Rotates 180° and locks in place for easy cleaning of outer pane |
Accessories | None.Locking handle.Guidance for specification option: code 028321 - For GPL top hung roof window only. |
Execution | Fixing of wood frames. |
Internal frame and sash | White painted. Guidance for specification option: Standard. Lacquered natural pine. |
External cladding: | Grey aluminium; colour reference NCS S-7500-N. Guidance for specification option: Code 0 |
Roof pitch | Guidance for specification option: Insert requirements. |
Roof window size code | GPL MK04 2070. Guidance for specification option: Standard size 780 mm wide x 978 mm high; effective daylight area, 0.47 m². GPL MK06 2070. Guidance for specification option: Standard size 780 mm wide x 1178 mm high; effective daylight area, 0.59 m². GPL MK08 2070. Guidance for specification option: Standard size 780 mm wide x 1398 mm high; effective daylight area, 0.72 m². GPL PK08 2070. Guidance for specification option: Standard size 942 mm wide x 1398 mm high; effective daylight area, 0.92 m². GPL PK10 2070. Guidance for specification option: Standard size 942 mm wide x 1600 mm high; effective daylight area, 1.07 m². |
Vertical window code | VFA MK35 2070. Guidance for specification option: Left hung, standard size 780 mm wide x 954 mm high; effective daylight area, 0.44 m² VFA MK36 2070. Guidance for specification option: Left hung, non-standard size 780 mm wide x 1154 mm high; effective daylight area, 0.56 m². VFA MK38 2070. Guidance for specification option: Left hung, non-standard size 780 mm wide x 1374 mm high; effective daylight area, 0.69 m². VFA PK35 2070. Guidance for specification option: Left hung, non-standard size 942 mm wide x 954 mm high; effective daylight area, 0.56 m². VFA PK36 2070. Guidance for specification option: Left hung, non-standard size 942 mm wide x 1154 mm high; effective daylight area, 0.71 m². |
Top-hung window | Not required. Blackout blind – Code DKL. Blackout energy blind – Code FHC. Duo blackout blind – Code DFD. External awning blind – Code MHL. |
Vertical window | Not required. Blackout blind – Code DKL. Blackout energy blind – Code FHC. Duo blackout blind – Code DFD. External awning blind – Code MIE. |
Flashing | EFL 0012. Guidance for specification option: For standard installation in slate up to 8 mm thick; roof pitch 15–55° EFN 0012. Guidance for specification option: For recessed installation in slate up to 8 mm thick; roof pitch 20–55° EFW 0012. Guidance for specification option: For standard installation in tiles up to 120 mm in profile. Also for interlocking slate, thatch and profile sheeting. roof pitch 15–55°. EFJ 0012. Guidance for specification option: For recessed installation in tiles up to 90 mm in profile; roof pitch 20–55°. ZWC. Guidance for specification option: For standard installation where an on-site flashing is required; roof pitch 15–90°. |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 1.7 kg·CO₂e/kg Self declared |
GBL Low Pitch, Centre-Pivot Roof Window
GCL Heritage conservation roof window
GDL Roof Balcony
GEL Roof Terrace
GGL Centre-Pivot Roof Window
GGL Electric, Centre-Pivot Roof Window with GIL Sloping Fixed Window Below
GGL Electric, Centre-Pivot Roof Window, Combination Installation
GGL Electric, Centre-Pivot Roof Window, Twin Installation
GGL Electric, Centre-Pivot Roof Window, with GIL Sloping Fixed Windows Below, Combination Installation
GGL Electric/ Solar Centre-Pivot Roof Window