Verified by manufacturer 7 months ago
One layer of Gyproc FireLine 15mm to one side of Gypframe 48 I 50 āIā Stud framework with 50mm Isover Steel Frame Infill Batts between studs forming an independent lining to structural steel columns, in association with external steel cladding (0.6mm). For heights up to 2400mm.
Finish | Manufacturer guidanceTo achieve the specified performances, the system should be finished using either one of our Thistle or ThistlePro plasters, or Gyproc jointing products. See the product range guides on the British Gypsum website for more information. |
Material | Gypsum Metal Plasterboard Steel Glass mineral wool |
Height | 2400 mm |
Uniclass | |
CAWS | K10/155 Wall lining system (metal studs) K10/30 Metal stud |
Product range |
Support | Base channel: Gypframe 50 FEC 50 Folded Edge Standard Floor & Ceiling Channel. |
Insulation | Insulation, Layer 1: 50mm Isover Steel Frame Infill Batt. |
Linings | Board side 1, Layer 1: Gyproc FireLine 15mm. |
Fasteners | Screws side 1, Layer 1: British Gypsum Drywall Screws 25mm. |
Joint treatment | Fixing strap: Gypframe GFS1 Fixing Strap. |
Finish | To achieve the specified performances, the system should be finished using either one of our Thistle or ThistlePro plasters, or Gyproc jointing products. See the product range guides on the British Gypsum website for more information. |
System accessories | Sealant: Gyproc Sealant. |
Execution | Please review details on the British Gypsum website at: https://www.british-gypsum.com/Specification/White-Book-Specification-Selector/wall-linings/GypLyner-Independent/B216026-A-EN#details |
Fire resistance | BS EN 1364-1, 60 / 30 Integrity / Insulation |
Strength grade | BS 5234-2, Heavy duty (HD) |
Partition height | 2400mm |
Background | Background: Steel Clad External Wall |