Verified by manufacturer 12 days ago
Acoustic separating floor system for concrete/ masonry floors, providing effective sound insulation under the screed. Building Regulations compliant and suitable for numerous building types.
Suitable for use in separating floor/ ceiling constructions in conversion, refurbishment and new build developments where a masonry structure is in place.
The system can be used to reduce sound transmission in domestic dwellings – houses and apartments – as well as buildings used for education, hotels, care homes, offices and hospitals.
Any building constructed using concrete separating floors may benefit from this system providing the floor and ceiling can both be treated.
Summary of building types that are most suitable for this system:
The HD1042 is an acoustic flooring system for separating floors which is designed to provide sound insulation under screed floors in all kinds of refurbishment, conversion and new build projects.
It has been fully tested as a complete system to demonstrate compliance with all the Building Regulations covering the UK - Approved Document E (England & Wales), Part G (Northern Ireland) and Section 5 (Scotland).
It is formed using Hush Acoustics' high quality acoustic materials including the Hush Under Screed 6 Membrane, RD flanking strip, Hush-Slab sound absorber and the Hush MF ceiling system. This is combined with GYPROC Soundbloc plasterboard to complete the system.
How the HD1042 Hush Underscreed 6 System is formed:
Acoustic Performance:
Impact (L’nT,w) - 48 dB
Airborne (DnT,w) - 51 dB
Airborne (DnT,w + Ctr) - 49 dB
*Results based on the full Hush System HD1042 being using and installed as listed above. All flanking paths must be treated correctly.
Features and benefits:
Components:
Color | Brown Grey White |
Finish | Unfinished |
Material | Timber Rubber Metal Mineral wool |
Shape | Rectangle |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Uniclass | |
CAWS | K11/275 Acoustic separating floor system |
Product range |
Suspension grid | Hush MF Ceiling System.Guidance for specification option: Metal grid system with acoustic hangers. |
Barriers in ceiling void | |
Acoustic barriers | Under Screed Acoustic Membrane.Guidance for specification option:
|
Isolating layer | Hush RD. Guidance for specification option:
|
Sound absorption | Hush Slab 100. Guidance for specification option:
|
Acoustic performance | Impact (Lntw): 48 dB. Airborne (Dntw): 51 dB. Airborne (Dntw +Ctr): 49 dB. |
Contains Red List materials | Manufacturer guidanceVaries according to the component or materials that are used to create the system. |
Country of material origin | Manufacturer guidanceVaries according to the component or materials that are used to create the system. |
Country of product manufacture | United Kingdom |
Material | Timber Rubber Metal Mineral wool |
Recyclability | Manufacturer guidanceVaries according to the component or materials that are used to create the system. |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | Manufacturer guidanceVaries according to the component or materials that are used to create the system. |