A fast drying one component, solvent-borne, physically drying intumescent coating for passive fire protection of structural steel against cellulosic fires.

Jump to:
+447827 448651 Website

Application

  1. As intumescent fire protection for internal and external structural steel up to C4. Suitable for open beams and columns and hollow sections.
  2. As a repair and touch-up coating for damaged areas of freshly applied Hempafire Pro 400 43490.
  3. As in-shop applied intumescent for increased application efficiency.
  4. Applied in up to 1600 micron (63 mils) dry film thickness per coat (equivalent to 2130 micron (84 mils) wet film thickness).

Description

To Specify a full Intumescent Fire Protection Coating System C1-C4 (Primer + Intumescent + Topcoat) click on the link below and add to your Chorus Specification:

Intumescent Fire Protection Coating Systems (C1–C4) - C1–C4 Corrosivity & Fire Protection | Hempel A/S | NBS Source (thenbs.com)


To Specify a full Anti-Corrosion System C1-C5 (No Intumescent Fire Protection) (Primer + Topcoat) click on the link below and add to your Chorus Specification :

Anti-Corrosion Protective Coating System (C1–C5) - For Corrosive Environments | Hempel A/S | NBS Source (thenbs.com)


For further advice on Specifications please contact Ian Morton at iam@hempel.com


Hempafire Pro 400 Fast Dry

A fast drying one component, solvent-borne, physically drying intumescent coating for passive fire protection of structural steel against cellulosic fires.


Features and benefits:

  • Very competitive loadings results in reduced paint consumption in PFP projects.
  • Faster drying times thanks to lower thicknesses to apply.
  • Very good aesthetic finish, easy to apply and suitable for in-shop and on-site.
  • Same product can be used for all type of steel sections (open, hollows, cellular beams).


Application method:

  • Airless spray.
  • Brush.


Drying time:

Determined for dry film thickness 800 micron (32 mils) at standard conditions. Indicative values at 20ºC; Surface dry: 15 minutes, Through-dry: 16 hours.

General information

Color

White

Manufacturer guidance

10000/ White.

Finish

Matt

Material

Intumescent

Shape

Formless

Length

Bespoke

Width

Bespoke

Height

Bespoke