NBS Source
I'm a manufacturer
Compare variants

ICS 5000 Generator - Flue System

Verified by manufacturer 5 months ago

ICS 5000 150 mm Vertical Installation

Schiedel Chimney Systems Variant:
Third party certifications:
  • DoP

    DoP

    Certificate type

Multi-functional twin wall insulated venting system.

Jump to:
BOS
+44 (0)191 416 1150 Website

Application

Suitable for use on heating appliances, stand-by gensets, CHP and service ducting.

Description

A multi-functional twin wall insulated venting system, which is suitable for internal and external use on a wide range of engineering, combustion and process equipment, including heating appliances, diesel generators, combined heat and power (CHP) systems and service ducting.


The product is supplied to a high quality specification as standard, including a 1.4404 (316L) grade stainless steel liner, high performance mineral blanket insulation and a bright annealed 1.4301 (304) grade stainless steel outer case.


Both liner and outer case have a continuous seam welded joint and each flue gas bearing component has a uniquely profiled spigot and socket joint with bevelled end forms to ensure ease of installation whilst ensuring the joint meets H1 performance criteria at 5000 Pa.


The thermal insulation blanket ensures continuous insulation over the entire effective length of the liner, ensuring fast priming to normal operating temperatures, whilst maintaining low external surface temperatures.


Chimneys are subject to significant corrosion attack by flue gas condensates, particularly from solid fuel and condensing appliances. ICS is specifically designed and manufactured to resist this corrosion. It is the only stainless steel chimney system in the world to have passed the internationally recognized Gastec corrosion test.


The chimney size should be as recommended by the appliance manufacturer. Where there is a requirement for a flue diameter smaller than the appliance spigot, then the operational requirements of the appliance and the configuration of the flue must satisfy the flue sizing requirements of BS EN 13384-1 for single appliances.


Features and benefits:

  • Engineered spigot and socket joint.
  • Pronounced lead in edge.
  • Quick and easy assembly.
  • Pressure gasket on outer case protected by insulation.
  • Continuous insulation avoids thermal bridging.
  • Inner liner free to expand and contract.
  • No requirement for expansion joints.
  • Lightweight.
  • No onsite welding or cutting required.


General information

Color

Silver

Finish

Stainless steel

Material

Stainless steel

Shape

Circle

Length

Bespoke

Width

Bespoke

Height

Bespoke

Warranty description

Ten year

Uniclass

Pr_70_65_30_51 Metal flues and chimneysPrimary

CAWS

S90/450 Metal flue pipes

T90/370 Metal flue pipes

T90/370 Metal flue pipes

S90/450 Metal flue pipes

Specification data - Metal flues and chimneys

Standard

To BS EN 1856-1, BS EN 1856-2, BS EN 1366-13, EN 1366-19, BS 476-20 and TÜV 0036 CPR 9195 027.

Construction

Twin wall.

Insulation

Integral, high performance mineral fibre, 25 mm.

Integral, high performance mineral fibre, 50 mm.

Material and finish

Stainless steel.

Accessories and fittings

Flange Adaptor – 116875.
Bend 90° – 114507.
Silencer.
Ceiling Hang – 112037.
200 Length – 112246.
Bend 45° – 112810.
Tee 45° – 117054.
Tee plug with drain – 113490.
Top plate – 115158.
Cantilevers – 101743.
500 pipe – 115908.
Silencer.
1000 pipe – 117967.
Wall Band – 101266.
1000 pipe – 117967.
Flat flashing kit – 127201.
Vertical Terminal – 126251.

Mode of operation

High positive pressure 5000 Pa (H1).

Pressure

5000 Pa.

FireRating

To BS 476-20: Four hours. To EN 1366-19: EI 120.

Seam

Fully seam welded.

Liner

1.4404 (316L) grade stainless steel : X2CrNiMo 17-12-2. (0.5 mm (Ø80 -350), 0.6 mm (Ø400-Ø600)).

Thermal resistance

25 mm 0.4 m²k/W, 50 mm 0.6 m²k/W (200°C).

Thermal shock resistance

1000°C.

Temperature

Firing temperature and continuous firing temperature: 600°C.
Short firing temperature: 700°C.

Sustainability data

Contains Red List materials

No

Country of material origin

Europe

Country of product manufacture

Europe

Recyclability

Can be recycled

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

80 %

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
Revit
-

1

IFC
-

1

Third party certifications

DoP

DoP

ICS 5000 Declaration of performance

Literature

ICS 5000 flue exhaust chimney and venting system

ICS 5000 flue exhaust chimney and venting system

Case studies

Home / Blog / Noise Reduction within Flue and Chimney Systems

Home / Blog / Noise Reduction within Flue and Chimney Systems

Similar products from Schiedel Chimney Systems

Boiler Installation with External Flue System (UK Plus) - Modular Concentric Flue System

Boiler Installation with External Flue System (UK Plus) - Modular Concentric Flue System

Cascade Boiler Installation with MF Flue System - Modular Twin Wall Insulated Flue System

Cascade Boiler Installation with MF Flue System - Modular Twin Wall Insulated Flue System