Verified by manufacturer 1 month ago
Isolating hanger for the construction of soundproof ceilings (reduces airborne and impact noise).
Ceiling soundproofing acoustic hangers for house conversion to flats, new build and renovation of houses and flats. Shops, restaurants and other commercial soundproofing applications.
Isolating acoustic hanger for the construction of soundproof ceilings (reduces airborne and impact noise).
Oscar Iso-Mount Type3 acoustic hangers fix direct to concrete, steel and plasterboard onto joist ceilings, with 100 mm void for insulation. Ceiling height loss is nominal: 100 mm plus the thickness of the new ceiling boards.
Oscar Iso-Mount Type3 acoustic hanger has an inbuilt + and – 10 mm height adjustment. That’s a 20 mm adjustment for levelling ceilings.
The maximum loading is 12.5 kg per mount; when evenly spaced, four Type3 Iso-Mounts per square metre gives a maximum loading of 50 kg/m².
Features and benefits:
Can be used in conjunction with:
Finish | Galvanized |
Material | Steel Guidance for specification option: (Mild). Rubber |
Shape | Manufacturer guidancePatented design. |
Height | 100 mm Guidance for specification option: Void. |
Uniclass | |
CAWS | K10/50 Suspended ceiling system on metal framing K10/245 Ceiling lining on timber K10/220 Proprietary suspended ceiling system K10/25 Ceiling lining on timber |
Product range |
Material | Mild steel and rubber. |
Component types | |
Ceiling hangers | Acoustic ceiling mount. |
Loading | 12.5 kg (maximum) per mount. Guidance for specification option: When evenly spaced, four Type3 Iso-Mounts per square metre gives a maximum loading of 50 kg/m². |
Sound insulation | Exceeds Building Regulations (E&W) Approved Document E requirements for airborne and impact sound. Guidance for specification option: Copies of tests are available from Oscar Acoustics. |
Adjustment | Plus (+) or minus (-) 10 mm in-built adjustment. Guidance for specification option: 20 mm adjustment for levelling ceilings. |
Contains Red List materials | No |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | Manufacturer guidanceCan effectively lower the carbon footprint of a building project by sequestering rich stores of carbon for the life of the structure or application. |
Recyclability | 75% |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 1 | |
- | 1 |