Double-headed shear rail reinforcement system to distribute punching shear forces in concrete floor slabs

Jump to:
+44 (0)1844 215 200 Website

Application

JDA shear rail units replace the need for drop beams or closely spaced traditional link reinforcement in floor slabs that are subject to punching shear loads. This reduces cost and reinforcement congestion.


Installed into the concrete from above, the stud rail units are positioned in floor slabs and foundation slabs to distribute punching shear loads above column or pile locations.


Typical Applications:

  • Flat slab concrete construction.
  • Precast filigree slabs.

Description

Double-headed stud reinforcement anchors are factory-welded to carrier rails. They are typically supplied in two to five anchor configurations.


Features and benefits:

  • High load transfer.
  • Reduces reinforcement congestion.
  • Enables flat slabs without thickening at columns or the need for drop beams.
  • European Technical Assessment - ETA-13/0136.

General information

Color

Black

Finish

Mill

Material

Steel

Shape

Other

Uniclass

Pr_20_96_71_67 Prefabricated reinforcementPrimary

CAWS

E30/240 Proprietary prefabricated reinforcement

Product range

Punching Shear Reinforcement

Specification data - Prefabricated reinforcement

Application

Shear heads.

Diameter

10–30 mm head diameter.

Guidance for specification option:

34.1 kN load bearing capacity.

12–36 mm head diameter.

Guidance for specification option:

49.2 kN load bearing capacity.

14–42 mm head diameter.

Guidance for specification option:

 66.9 kN load bearing capacity.

16–48 mm head diameter.

Guidance for specification option:

87.4 kN load bearing capacity.

20–60 mm head diameter.

Guidance for specification option:

136.6 kN load bearing capacity.

25–75 mm head diameter.

Guidance for specification option:

213.4 kN load bearing capacity.

Third party certification

European Technical Assessment - ETA-13/0136.

Number

Guidance for specification option:

Insert requirement.

Anchor length

125–695 mm.

Guidance for specification option:

Insert requirement, available 125–695 mm dependent on anchor diameter.

Anchor spacing

Guidance for specification option:

Insert requirement.

Strip length

200–665 mm.

Guidance for specification option:

Insert requirement, available 200–665 mm dependent on anchor diameter and length.

Materials

Steel.

Guidance for specification option:

  • Double-headed anchors: B500B steel.
  • Perforated connecting strip: Structural steel.


Sustainability data

Country of product manufacture

Germany

Material

Steel

Embodied carbon

A1-A3 (production stage) as defined in BS EN 15804

-

Manufacturer guidance

Refer to EPD document

Recyclability

-

Manufacturer guidance

Refer to EPD document

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

-

Manufacturer guidance

Refer to EPD document

Third party certifications

Third party certifications

EPD

EPD

EPD-Jordahl Punching Shear Reinforcement JDA

European Technical Approval (ETA)

European Technical Approval (ETA)

European Technical Assessment for JORDAHL PUNCHING SHEAR REINFORCEMENT - JDA - ETA-13/0136

UK Technical Assessment (UKTA)

UK Technical Assessment (UKTA)

UK Technical Assessment - Punching Shear Reinforcement JDA

LEED US

LEED US

LEED Assessment Jordahl Punching Shear Reinforcement JDA

Literature

Jordahl Punching Shear Reinforcement JDA

Jordahl Punching Shear Reinforcement JDA

Installation Instructions Jordahl Punching Shear Reinforcement JDA

Installation Instructions Jordahl Punching Shear Reinforcement JDA