Verified by manufacturer 3 months ago
S3-P0K - Single Phase
Ground source heat pumps with with A+ energy-related product (ErP) rating.
Suitable for flats, apartments, new builds and district heating schemes.
The Kensa Shoebox range of heat pumps are designed to provide space heating and domestic hot water (optional extra) for well insulated buildings with multiple accommodation. By using a communal ground array this avoids the high heat losses associated with running high temperature pipe throughout buildings improving the overall efficiency of the system.
The Shoebox heat pump is designed specifically to operate with low noise levels enabling easy installation in places such as an apartment’s kitchen.
The unit has been specifically designed to provide a renewable alternative for heating multiple apartment blocks.
The Shoebox heat pump is available in two sizes; a 3 kW version and 6 kW version. Both units come complete with the ground side water pump internal to the unit reducing the complexity of installation.
Features and benefits:
Color | White |
Finish | Gloss |
Material | Steel |
Shape | Rectangle |
Length | 360 mm Guidance for specification option: Depth. 595 mm |
Width | 480 mm 610 mm |
Height | 515 mm 585 mm |
Warranty description | Two year Guidance for specification option: Controller and water pumps. Five year Guidance for specification option: Core heat pump unit (refrigeration components). |
Uniclass | |
CAWS | T90/525 Ground heat exchangers T90/525 Ground heat exchangers |
Loop depth | Guidance for specification option: Consult manufacturer and insert requirements. |
Pipe diameter | 22 mm. |
Borehole diameter | Guidance for specification option: Consult manufacturer and insert requirements. |
Thermal | 3.0 kW. Manufacturer guidanceNominal thermal kW rating. |
Power consumption | 0.8 kW. |
CoefficientOfPerformance | To EN 14511, 3.54. |
Flowrate | 9.2 kg/min (brine); 7.8 L/min (heating water). Guidance for specification option:
|
PressureDrop | 5 kPa (brine); 3.8 kPa (heating water). Guidance for specification option:
Manufacturer guidancePressure drop kPa at design flow rate. |
WaterInletTemperatureRange | -5℃ to 25℃. Manufacturer guidanceMin–max inlet temperature. |
Heating secondary flow temperature (UFH) | 65℃. |
RatedVoltage | 220–240 V (50–60 Hz). |
Power supply | 16 A. Manufacturer guidanceRating amps. |
RatedCurrent | 7 A. Manufacturer guidance(Maximum) amps. |
Process medium | R134a. |
InternalRefrigerantVolume | 0.8 kg. Manufacturer guidanceFill volume kg. |
Compressor | Reciprocal. |
Dimensions | 515 x 480 x 360 mm. |
Dry weight | 62 kg. |
Rating | A+. Manufacturer guidanceErP rating. |
Overall sound power level | 47 dBA. |
Country of product manufacture | United Kingdom |
Material | Steel |
Recyclability | Disposal/Decommissioning |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 1 | |
- | 1 |