The NCCTL is for use in an exterior masonry skin in conjunction with a non-masonry inner leaf such as a steel frame system.
A non-combustible stainless steel single-leaf lintel with combined cavity tray.
All Keyfix Non-Combustible Cavity Tray Lintels satisfy the thermal performance requirements of Approved Document L of the Building Regulations (E & W), Northern Ireland’s Technical Booklet F, and Scotland’s Technical Handbook, section 6. The NCCTL satisfy fire safety requirements of Approved Document B of the Building Regulations within buildings over 11 m in height.
Reaction to fire classification = A1 (non-combustible) in accordance with BS EN 13501-1 as defined in 96/603/EC. Meets the requirements of material/coating specification requirements within PD6697. The patented NCCTL prevents thermal bridging. Keyfix's NCCTL conforms to the requirements of a cavity tray satisfying the NHBC & LABC Warranty technical guidance.
The NCCTL patented mechanically fixed Stop Ends are prepositioned within perpend joints to accommodate brickwork openings. The installation of the NCCTL requires no additional specialist skills. The ease of installation in the outer leaf combines the structural load-bearing lintel with the advantages of a self-supporting cavity tray.
For more detailed information applicable to a particular wall construction, contact Keyfix Technical Department at info@keyfix.com or call us at +44 (0)28 8676 7508.
Refer to manufacturers' literature for details regarding lintel ranges, height, thickness, and Uniformly Distributed Load (UDL) figures.
Performance:
Fire:
Corrosion:
Structural:
Certification:
Galvanized steel:
Additional features:
Contact Keyfix Technical Department for further information.
Color | Silver |
Finish | Galvanized Metallic Manufacturer guidanceCold-rolled stainless steel. |
Material | Steel Guidance for specification option:
Stainless steel Guidance for specification option:
|
Length | Manufacturer guidanceRefer to Keyfix NCCTL Datasheet or contact Keyfix Technical Department for further information. |
Uniclass | |
CAWS | F30/755 Prefabricated steel lintels F30/85 Prefabricated steel lintels |
Standard | To BS EN 845-2.Guidance for specification option: UKCA and CE marked to BS EN 845-2 specification for ancillary components for masonry Part 2: Lintels. |
Lintel type | Composite. |
Material finish and coating reference | Galvanized mild steel to BS EN ISO 1461 DX51D with a zinc coating of 710 g/m² (including both sides), material coating reference L10.Austenitic stainless steel, grade 304 2B to BS EN 10088-2 ASTM 240 (European Grade 1.4307), material coating reference L3.Austenitic stainless steel, grade 316 2B to BS EN 10088-2 ASTM 316/316L (European Grade 1.4404), material coating reference L1.Guidance for specification option: For coastal locations. |
Sizes | As lintels schedule.Guidance for specification option: Refer to Keyfix NCCTL Datasheet or contact Keyfix Technical team. To suit cavity widths greater than 50 mm (UKCA and CE). |
Characteristics | |
Resistance to fire | A1.Guidance for specification option: Has achieved a minimum period of 120 minutes in accordance with BS EN 1363-1. |
Thermal conductivity | Part L compliant.Guidance for specification option: Consult manufacturer for further details. |
Duty | Standard duty. Heavy duty. Extra heavy duty. |
Bearing | 150 mm minimum. |
Accessories | Keyfix Non-combustible Weep (NCW). Keying options to suit required plastering applications. Cavity closer. Cant brick. Powder-coating. |
Material | Steel Guidance for specification option:
Stainless steel Guidance for specification option:
|
Recyclability | 100% Recyclable |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 65 % |