Kingspan Thermataper TT44-K - Tapered Roof Insulation with Kooltherm

Verified by manufacturer 3 months ago

≥120 mm thick (0.024 W/m·K)

Kingspan Insulation Variant:
Third party certifications:
  • ISO 45001 Health and Safety Management

    Certificate type

  • ISO 9001 Quality Management

    Certificate type

  • ISO 37301 (Compliance Management Systems)

    Certificate type

Tapered roof insulation combined with Kooltherm packer board.

Jump to:
BOS
+44 (0)1544 388601 Website

Application

Suitable for use on new and existing roofs with timber or concrete decks.

Description

Kingspan Thermataper TT44 tapered roof insulation combined with Kooltherm packer board for reduced overall thickness.


Kingspan Thermataper TT44 tapered roof insulation and Kingspan Kooltherm packer board are both manufactured under a management system certified to ISO 9001: 2015 (Quality Management Systems. Requirements), ISO 14001: 2015 (Environmental Management Systems. Requirements), ISO 45001: 2018 (Occupational Health and Safety Management Systems), ISO 50001: 2018 (Energy Management Systems. Requirements with guidance for use) and ISO 37301: 2021 (Compliance Management Systems. Requirements with guidance for use).


Features and benefits:

  • Potential thickness savings of 20–40 mm (dependent on the individual scheme and build-up, when compared with a full Polyisocyanurate (PIR) system).
  • No structural fall required.
  • For refurbishment applications, and can typically be installed above the existing roof surface (with a waterproof membrane).

General information

Color

Yellow

Guidance for specification option:

Kingspan Thermataper TT44 boards.

Pink

Guidance for specification option:

Kingspan Kooltherm packer board.

Finish

Smooth

Material

Polyisocyanurate (PIR)

Guidance for specification option:

Kingspan Thermataper TT44 boards.

Phenolic resin

Guidance for specification option:

Kooltherm Packer

Shape

Square

Guidance for specification option:

Tapered TT44 boards

Length

1200 mm

Width

1200 mm

Uniclass

Pr_25_71_63_66 Polyisocyanurate (PIR) foam boardsPrimary

CAWS

J41/420 Rigid urethane foam insulation

J42/420 Rigid urethane foam insulation

J41/26 Thermal insulation

J42/27 Thermal insulation

Product range

Therma

Specification data - Polyisocyanurate (PIR) foam boards

Fire performance

To BS EN 13501-1:2018, RtF F; RtF C-s2.

Guidance for specification option:

Kingspan Thermataper TT44 boards; Kingspan Kooltherm packer board.

Thermal conductivity (maximum)

0.026 W/m·K (insulation); 0.019 W/m·K (packer board).

Guidance for specification option:

<80 mm.

Water permeability

Manufacturer's standard.

Guidance for specification option:

Consult manufacturer for details.

Water vapour permeability

Manufacturer's standard.

Guidance for specification option:

Consult manufacturer for details.

Acoustic performance

Manufacturer's standard.

Guidance for specification option:

Consult manufacturer for details.

Compressive strength at 10% deformation

120 kPa.

Thickness (nominal)

-

Manufacturer guidance

Refer to manufacturer's literature or Technical Services department for details of available thicknesses.

Face size (length x width)

1200 x 1200 mm.

Density

Manufacturer's standard.

Guidance for specification option:

Consult manufacturer for details.

Recycled content

0% (minimum) to BS EN ISO 14021.

Facing

Bitumen coated glass tissue finished with a thermofusible polypropylene fleece autohesively bonded to the insulation core

Manufacturer guidance

Kingspan Thermataper TT44 boards.

Board facing

Mineralized glass tissue autohesively bonded to the insulation core.

Manufacturer guidance

Kingspan Kooltherm packer board.

Core

Rigid thermoset fibre-free polyisocyanurate (PIR) insulant.

Manufacturer guidance

Kingspan Thermataper TT44 boards.

Core board

Fibre-free rigid thermoset phenolic insulant.

Manufacturer guidance

Kingspan Kooltherm packer board.

Sustainability data

Material

Polyisocyanurate (PIR)

Guidance for specification option:

Kingspan Thermataper TT44 boards.

Phenolic resin

Guidance for specification option:

Kooltherm Packer

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
Revit
-

1

IFC
-

1

Third party certifications

ISO 45001 Health and Safety Management

ISO 45001 Health and Safety Management

ISO 45001:2018 - Pembridge

ISO 9001 Quality Management

ISO 9001 Quality Management

ISO 9001:2015 - Pembridge

ISO 37301 (Compliance Management Systems)

ISO 37301 (Compliance Management Systems)

ISO 37301:2021 - Pembridge

Literature

Thermataper TT47-K Brochure

Thermataper TT47-K Brochure

Similar products from Kingspan Insulation

Kingspan Thermafloor TF70 - Insulation for Ground Floors

Kingspan Thermafloor TF70 - Insulation for Ground Floors

Kingspan Thermapitch TP10

Kingspan Thermapitch TP10

Kingspan Thermaroof TR24 - Flat Roof Insulation

Kingspan Thermaroof TR24 - Flat Roof Insulation

Kingspan Thermaroof TR26 - Flat roof insulation

Kingspan Thermaroof TR26 - Flat roof insulation

Kingspan Thermaroof TR27 - Flat roof insulation

Kingspan Thermaroof TR27 - Flat roof insulation

Kingspan Thermataper TT44 - Tapered Roof Insulation

Kingspan Thermataper TT44 - Tapered Roof Insulation

Kingspan Thermataper TT46 - Tapered Insulation Board

Kingspan Thermataper TT46 - Tapered Insulation Board

Kingspan Thermataper TT47 - Rigid PIR Insulation Board

Kingspan Thermataper TT47 - Rigid PIR Insulation Board

Kingspan Thermataper TT47-K

Kingspan Thermataper TT47-K

Kingspan Thermawall TW50 - Partial Fill Cavity Wall Insulation

Kingspan Thermawall TW50 - Partial Fill Cavity Wall Insulation