NBS Source
I'm a manufacturer

LineAL-F Aluminium Cladding System

Verified by manufacturer 5 months ago

Ash & Lacy

Rainscreen plank system.

Jump to:
BOS
+44 (0)121 525 1444 Website

Application

Suitable for vertical and horizontal applications.

Description

Aluminium rainscreen plank system with interchangeable and repeatable modules, fixed to a fully adjustable secondary support system.


Features and benefits:

  • A cost-effective, secret-fix aluminium plank system, suitable for linear module facades with face modules between 100 mm and 400 mm, and panel lengths up to 3800 mm.
  • Designed to seamlessly integrate with all other building facade elements such as windows, doors and louvres.
  • Panels can be orientated vertically or horizontally to suit design and budget requirements.
  • CWCT Tested
  • Fire tested to EN13501-1 - A1 and A2,s1-d0 options
  • BBA certification (in progress)
  • Fully fabricated cranked or trimmed corner panels available for ease and consistency of installation.
  • Variable joint arrangement options to ensure optimum ventilation, and flexibility in design options.
  • Available in an extensive range of colours and finishes including anodized shades, and specialist powder coatings.

General information

Color

Beige

Black

Blue

Bronze

Brown

Show more

Finish

Anodized

Powder-coated

Material

Aluminium

Shape

Rectangle

Length

3800 mm

Height

200 mm

400 mm

300 mm

150 mm

100 mm

Warranty description

25 year

Uniclass

Ss_25_20_70_25 Drained and back-ventilated rainscreen cladding systemsPrimary

CAWS

H92/120 Rainscreen cladding

Specification data - Drained and back-ventilated rainscreen cladding systems

System performance

Fire performance: Reaction to fire to EN 13501-1, Euroclass A1.

Guidance for specification option:

With no coating or anodized coating.

Fire performance: Reaction to fire to EN 13501-1, Euroclass A2-s1, d0.

Guidance for specification option:

With PPC coating.

Secondary support structure

L rails and brackets.

T rails and brackets.

Manufacturer guidance

- L Rails:

  • Length: 3000–6000 mm.
  • Leg: 60 mm.
  • Face: 40 mm.

- T Rails:

  • Length: 3000–6000 mm.
  • Leg: 40–80 mm.
  • Face: 80–140 mm.

- Bracket:

  • AxiAL bracket range: 90–300 mm.

Cladding panels

-

Material

3 mm Solid aluminium.

2 mm Solid aluminium.

3 mm Perforated aluminium.

2 mm Perforated aluminium.

Panel joints

Panel interlock and vertical joints.

Guidance for specification option:

Panel interlock: 10 mm (standard), 100 mm (maximum), 10 mm (minimum).

Vertical joint: 10 mm (standard), 20 mm (maximum), 10 mm (minimum).

Insert requirements.

Corner treatments

Not required.

Guidance for specification option:

For LineAL-X.

Preformed.

Trimmed.

Colour/ Finish

Anodized.

Powder-coated.

Manufacturer guidance

Consult manufacturer and insert requirements.

Sustainability data

Contains Red List materials

No

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
Revit
-

1

IFC
-

1

Similar products from Ash & Lacy

MechSlip Brick Cladding

MechSlip Brick Cladding

NaturAL-X Brick Cladding

NaturAL-X Brick Cladding

VariAL-CF1 Aluminium Cladding System

VariAL-CF1 Aluminium Cladding System

VariAL-CF2 Aluminium Cladding System

VariAL-CF2 Aluminium Cladding System

VariAL-CF3 Aluminium Cladding System

VariAL-CF3 Aluminium Cladding System

VariAL-H Aluminium Cladding System

VariAL-H Aluminium Cladding System

VariAL-TF Metal Cladding System

VariAL-TF Metal Cladding System