Verified by manufacturer 1 month ago
Wet room tanking/ waterproofing kit for indoor use.
Paint on application that can be applied on concrete, plaster, light clinker concrete, screed, lightweight concrete, floor plywood, stucco, gypsum floors, calcium silicate plates and various approved wetroom plasterboards, gypsum fibre, cement and polystyrene.
Apply LIP VS30 with a brush, roller or scraper twice on all surfaces when the primer has dried. The drying time on the first layer is approximately 1–2 hours. The drying time for the second layer is approximately 8–16 hours depending on temperature and humidity. Working temperature should be minimum 10°C.
WM | Wetroom Materials - LIP VS30 is a one-component liquid membrane used for waterproofing floor and wall cladding before cladding with ceramic tiles or natural stone in wet rooms. To be used with Primer 54 or Supergrund and reinforcement tape.
Features and benefits:
In the areas where a layer thickness of at least 1 mm is required, consumption is 1.73 kg/m². This applies in accordance with applicable building regulations, SBI instructions. In the areas where only a waterproof layer is required, the layer thickness must be a minimum of 0.58 mm at a consumption of 1 kg/m². For radon protection, a minimum application of 1.0 mm.
The substrate must be dust-free, firm, dry and free of release agents. Cement, plaster, lightweight clinker concrete, screed, gypsum plaster, plaster floors, aerated concrete and other inorganic materials are primed with LIP primer 54, diluted one-part primer and ten parts water.
Wet room floor drains must be approved lubrication membranes on the respective substrates and the supplier's instructions must be followed.
Color | Blue Grey |
Material | Acrylic |
Shape | Formless |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | Ten year |
Uniclass | |
CAWS | M40/115 Natural stone covering to M40/10 Natural stone covering to J30/10 Cold-applied damp-proofing J30/130 Cold-applied damp-proofing M40/110 Tiling to M40/5 Tiling to |
Composition | Liquid-based. |
Working temperature | 10–30°C. |
Adhesion strength | 0.8–1.2 N/mm². Manufacturer guidanceOn concrete. |
Integral accessories | Reinforcement tape. |
Material | Acrylic |