Versatile GRC façade/cladding system is a lightweight alternative to precast. Offering fully customizable 3D profiles, colours and textures.

Jump to:
+44 (0)1902 797700 Website

Application

Wide range of applications beyond common adopted use for small, medium and large format panel systems. Provides a lightweight, high impact, total façade rainscreen cladding solution.

Description

GRC is a composite material comprising of cement, fine aggregates, alkali resistant glass fibres, acrylic polymers and admixtures/ additives.


Features and benefits:

  • Fire classification A1 or A2-s1,d0 to BS EN 13501.
  • Weight, to promote savings in the ground and the structural frame.
  • Speed of installation, removing the need for multiple trade contractors.
  • High quality, obviating the skills shortages upon high rise structures.
  • Logistics in material distribution and access strategy. 
  • Programme, whereby the façade is wholly removed from the critical path and is supplied to site on a just in time basis.
  • Tower cranes –the reliance upon these for the external facade is reduced with installation can be achieved by monorail/mast climber or spider crane.
  • Highly durable composite material with high impact strength, ideal for areas of high traffic.
  • non corrosive, low maintenance
  • EPD value of 26 kg CO₂ eq/m².
  • Weight = 65 kg/m².

General information

Color

Beige

Black

Bronze

Brown

Cream

Show more

Manufacturer guidance

A wide range of tinting and colour options can be utilized in the manufacturing process.

Finish

Shot blasted

Sandblasted

Brick

Coarse

Fine

Show more

Material

Concrete

Guidance for specification option:

Glass fibre reinforced concrete.

Shape

Diamond

Crescent

Hexagon

Elliptical

Octagon

Show more

Manufacturer guidance

Bespoke - project specific facade solution.


Length

Bespoke

Guidance for specification option:

Up to 7 m (theoretical max).

7000 mm

Guidance for specification option:

Theoretical max.

Width

Bespoke

Guidance for specification option:

Up to 2.5 (theoretical max).

2500 mm

Guidance for specification option:

Theoretical max.

Height

Bespoke

Guidance for specification option:

Up to 4.5 m (theoretical max).

4500 mm

Guidance for specification option:

Theoretical max.

Warranty description

12 year

Uniclass

Ss_25_20_33_35 Glass fibre-reinforced concrete (GRC) wall cladding systemsPrimary

CAWS

H92/120 Rainscreen cladding

H40/110 GRC cladding

Specification data - Glass fibre-reinforced concrete (GRC) wall cladding systems

Classification data

Cladding panels and facade components

Glass fibre reinforced concrete grade 18P.

Stiffening frames

Project specific.

Guidance for specification option:

Insert requirement.

Fixings

-

Loadbearing fixings

-

Form

Project specific.

Guidance for specification option:

Insert requirement.

Fasteners to primary structure

As fixings schedule.

Guidance for specification option:

Stainless steel fixings.

Restraint fixings

-

Form

As fixings schedule.

Guidance for specification option:

Stainless steel fixings.

Fasteners to structure

As fixings schedule.

Guidance for specification option:

Stainless steel fixings.

Isolation of fixings

Inter metallic isolation.

Jointing

-

Joint sealants

Project specific.

Guidance for specification option:

Consult manufacturer and insert requirements.

Joint filler

Project specific.

Guidance for specification option:

Consult manufacturer and insert requirements.

Air barrier

-

Manufacturer guidance

Supplied by others.

Thermal insulation

By others.

Thermal insulation fasteners.

By others.

Breather membrane

-

Material

By others.

Fasteners

By others.

Cavity fire barriers

-

Horizontal

By others.

Vertical

By others.

System accessories

Guidance for specification option:

Consult manufacturer and insert requirement.

Samples required

Brick facing.

Guidance for specification option:

Sample panel of a size that adequately represents the natural variation characteristics of the selected brick(s) should be manufactured.

Colour

Standard facing.

Guidance for specification option:

Wide range of colours available. Consult manufacturer and insert requirement.

Brick facing.

Guidance for specification option:

Natural colour variations and surface characteristics are dependent on brick type and manufacturer specified in addition to the joint mortar utilized.

Sizes

Guidance for specification option:

Bespoke, consult manufacturer and insert requirements.

Theoretical max:

  • Non strong back = 4.5 x 2.5 m.
  • Strong back = 3 x 7 x 2.5 m.

Modulus rupture

18–30 N/mm².

TensileStrength

8–12 N/mm².

ShearStrength

2–4 N/mm².

Impact resistance

15–25 N/mm².

Dry density

1800–2100 Kg/m³.

Water absorption

8–13%.

Porosity

16–21%.

Reaction to fire

To BS EN 13501-1, A1 and A2s1d0.

Sustainability data

Contains Red List materials

No

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

A1–A3 ('Production stage')

Normalized unit

Declared unit

26 kg CO₂ eq/m²

Self-declared

Lower emissions

Case studies

London South Bank University

London South Bank University

50-60 Station Road  Cambridge

50-60 Station Road Cambridge

Similar products from Ibstock Telling

Brick Faced Norskreen Glass Fibre Reinforced Concrete Panel System

Brick Faced Norskreen Glass Fibre Reinforced Concrete Panel System