NBS Source
I'm a manufacturer
Compare variants

Planibel Clearlite

Verified by manufacturer 6 months ago

3 mm thick

AGC Glass UK Ltd Variant:

Float glass

Jump to:
+44 (0)1788 535353 Website

Application

Glazing

Description

Float glass


Features and benefits:

  • Delivers improved comfort in homes.
  • Cradle to Cradle Certified™ Bronze.
  • High light transmission of 90%: Increases the amount of natural light entering a building and reduces the need for artificial lighting, resulting in a more comfortable environment.
  • Low energy absorption of 5%: Reduces the risk of thermal shock.
  • High energy transmission of 87%: Improves passive energy gain.
  • High solar factor of 88%: Can increase the overall energy balance of a window and lead to a positive impact in the Window Energy Rating (WER).

General information

Color

Clear

Material

Glass

Shape

Rectangle

Length

Bespoke

Width

Bespoke

Height

Uniclass

Pr_25_71_33_88 Thermally toughened glass sheetsPrimary

CAWS

L40/530 Internal tape glazing

L40/490 Single-sided gasket glazing

L40/470 Zipper gasket glazing

L40/450 Single glazing into grooves – sealant capping

L40/430 Single glazing into grooves – non-setting compound

L40/410 Single glazing into grooves – extruded rubber/ PVC sections

L40/381 Bead-fixed insulating glass units – solid bedding, inside bead

L40/380 Bead-fixed insulating glass units – solid bedding, outside bead

L40/372 Bead-fixed insulating glass units – loadbearing tapes/ synthetic rubber and sealant capping

L40/371 Bead-fixed insulating glass units – cellular adhesive/ mastic tape

L40/370 Bead-fixed insulating glass units – insert gasket sections

L40/350 Bead-fixed single glazing – curing compound and trim

L40/330 Bead-fixed single glazing – capping

L40/310 Bead-fixed single glazing – tape, sealant and trim

L40/260 Bead-fixed single glazing – extruded gasket

L40/250 Bead-fixed single glazing – tape and sealant

L40/230 Bead-fixed single glazing – non-setting compound

L40/210 Putty-fronted single glazing

L40/90 Internal tape glazing

L40/58 Bead-fixed insulating glass units – solid bedding, inside bead

L40/57 Bead-fixed insulating glass units – solid bedding, outside bead

L40/55 Bead-fixed insulating glass units – drained and ventilated bead

L40/50 Bead-fixed single glazing

L40/40 Putty-fronted single glazing

L10/580 Secondary glazing system

L10/400 Composite windows

L10/390 Proprietary windows

L10/350 PVC-U windows

L10/330 Aluminium windows

L10/310 Steel windows

L10/210 Wood windows

L10/58 Secondary glazing system

L10/33 Proprietary windows

L10/31 PVC-U windows

L10/30 PVC-U windows

L10/25 Aluminium windows

L10/20 Steel windows

L10/15 Wood windows

L10/10 Wood windows

H10/115 Patent glazing

H10/10 Patent glazing

Specification data - Thermally toughened glass sheets

General requirements

Glass generally.

Third-party certification

Cradle to Cradle Certified™ Silver.

Composition

Manufacturer's standard.

Toughening process

Manufacturer's standard.

Thickness

3 mm.

Body colour

Clear.

Pattern

-

Manufacturer guidance

Insert requirements where applicable or delete item.

Edge detail

Manufacturer's standard.

Edge grinding.

Guidance for specification option:

Insert requirements.

Manufacturer guidance

See also 'Processing' below for related options.

Hole requirements

Not required.

Drilling.

Guidance for specification option:

Insert requirements.

Notches.

Guidance for specification option:

Insert requirements.

Manufacturer guidance

See also 'Processing' below for related options.

Edgework and holes

Complete before toughening.

Coating

-

Type

Not required.

Reflective, silvering.

Paint.

Guidance for specification option:

Insert requirements, including colour.

Design

-

Manufacturer guidance

Insert requirements; specify colour requirements below.

Performance requirements

-

Fire performance

Manufacturer's standard.

Guidance for specification option:

Consult manufacturer for details.

Light

Transmittance: 91%.

Solar control

Solar factor: 89%.

Total shading coefficient

Manufacturer's standard.

Guidance for specification option:

Consult manufacturer for details.

Thermal insulation

Manufacturer's standard.

Guidance for specification option:

Consult manufacturer for details.

Sound attenuation

Manufacturer's standard.

Guidance for specification option:

Consult manufacturer for details.

Impact resistance

Manufacturer's standard.

Guidance for specification option:

Consult manufacturer for details.

Worked finish

-

Method

Not required.

Sandblasted.

Etching.

Design

-

Manufacturer guidance

Insert requirements where applicable.

Applied detail

None.

Silk-screen printing and enamelling.

Guidance for specification option:

Insert requirements.

Processing

Not required.

Cutting, straight.

Guidance for specification option:

Insert requirements.

Cutting, circular.

Guidance for specification option:

Insert requirements.

Grinding.

Guidance for specification option:

Insert requirements.

Bending.

Guidance for specification option:

Insert requirements.

Manufacturer guidance

Consult manufacturer for further details.

See also 'Edge detail' and 'Hole requirements' above for related options.

Safety

Toughening/ heat strengthening.

Laminating (PVB).

Laminating (EVA).

Not required.

Glazing units

Not required.

Double glazed IGUs.

Triple glazed IGUs.

Sustainability data

Contains Red List materials

No

Country of material origin

Europe

Country of product manufacture

Europe

Recyclability

Fully recyclable

Similar products from AGC Glass UK Ltd

Lacobel T

Lacobel T

Luxclear™

Luxclear™

Matelac T

Matelac T

Matelux

Matelux

Planibel Coloured

Planibel Coloured

Planibel Low-E

Planibel Low-E