NBS Source
I'm a manufacturer
Compare variants

Pro-Cut Deflection Head (British Gypsum)

Verified by manufacturer 2 months ago

British Gypsum 50EDC70

Drywall Pro-cut Ltd Variant:

Deflection head designed to provide resilient fixing to connect the top of British Gypsum partitions to the underside of a structural slab or soffit.

Jump to:
01827 213201 Website

Application

  • Deflection head designed to provide resilient fixing to connect the top of British Gypsum partitions to the underside of a structural slab or soffit.
  • All materials and fixings are installed off site in a quality-controlled environment and delivered safely to site.
  • See project-specific British Gypsum detailing for specified partitioning systems for guidelines on site installation.

Description

Deflection head designed to provide resilient fixing to connect the top of British Gypsum partitions to the underside of a structural slab or soffit. Product allows for building deflection and movement to accommodate and minimize stress development in partitions that could result in yielding of studs, visible cracking or failure of serviceability limit states.


Fabricated in an offsite environment to maximize safety and ensure high levels of quality and compliance with associated regulatory requirements and manufacturer warranties. Complies with all thermal and acoustic requirements as a critical component of the extensive range of British Gypsum partitioning systems whilst providing high levels of protection against fire for periods of up to 120 minutes in standard applications.


Features and benefits:

  • Wide selection of deflection heads available to accommodate standard deflections in the range of 15—50 mm.
  • Metal sections all meet BS EN 14195:2014 requirements for metal framing components for gypsum board systems.
  • Standard installation in accordance with British Gypsum recommendations can provide 60—120 minutes fire protection as necessitated in Building Regulations Approved Document B and supporting documentation (e.g. HTM05/BB100).
  • Fire testing of full partitioning systems containing this product or equivalent conducted according to BS EN 1364-1:1999.
  • Gypframe metal channels are 100% recyclable (European Waste Catalogue code is 12 01 01).
  • Gypsum based components can be fully recycled provided they are not contaminated by non-gypsum materials.
  • Component complies with British Gypsum SpecSure® warranty verifying that approved partitioning systems will perform as specified upon installation and will continue to do so throughout the design life of the building.
  • Additional fire protection in the form of Gyproc FireStrip is also capable of being included/installed as required.

General information

Color

Silver

White

Material

Metal

Gypsum

Plasterboard

Shape

Rectangle

Length

3600 mm

Width

50 mm

62 mm

72 mm

94 mm

148 mm

Height

60 mm

70 mm

80 mm

Warranty description

Other

Guidance for specification option:

Component complies with British Gypsum SpecSure® warranty verifying that approved partitioning systems will perform as specified upon installation and will continue to do so throughout the design life of the building.

Uniclass

Ss_25_10_30_35 Gypsum board partition systemsPrimary

CAWS

K10/30 Metal stud

K10/125 Metal stud partition system

Specification data - Gypsum board partition systems

Framing

British Gypsum 50EDC70.

Manufacturer guidance

Metal Track Selections.

Resilient layer

Not required.

Resilient bar one side.

Resilient bar two sides.

Fire separation

-

Cavity fire barriers

Not required.

Gyproc Firestrip.

Guidance for specification option:

  • Gyproc Firestrip available for fitting between metal track and plasterboard if requested.
  • Gyproc Firestrip supplied loose for fixing between plasterboard and soffit if requested.

Linings

British Gypsum 19 mm Coreboard one layer.

Guidance for specification option:

  • Reaction to fire: A2-s1, d0.
  • Thermal conductivity: 0.24 W/mk.
  • Minimum weight: 16 kg/m².
  • No. of layers: 1.

British Gypsum 15 mm Glasroc F FIRECASE one layer.

Guidance for specification option:

  • Reaction to fire: A1.
  • Thermal conductivity: 0.30 W/mk.
  • Minimum weight: 11.8 kg/m².
  • No. of layers: 1.

British Gypsum 20 mm Glasroc F FIRECASE one layer.

Guidance for specification option:

  • Reaction to fire: A1.
  • Thermal conductivity: 0.30 W/mk.
  • Minimum weight: 15.8 kg/m².
  • No. of layers: 1.

British Gypsum 25 mm Glasroc F FIRECASE one layer.

Guidance for specification option:

  • Reaction to fire: A1.
  • Thermal conductivity: 0.30 W/mk.
  • Minimum weight: 19.9 kg/m².
  • No. of layers: 1.

British Gypsum 30 mm Glasroc F FIRECASE one layer.

Guidance for specification option:

  • Reaction to fire: A1.
  • Thermal conductivity: 0.30 W/mk.
  • Minimum weight: 23.9 kg/m².
  • No. of layers: 1.

British Gypsum 19 mm Coreboard two layers.

Guidance for specification option:

  • Reaction to fire: A2-s1, d0.
  • Thermal conductivity: 0.24 W/mk.
  • Minimum weight: 16 kg/m².
  • No. of layers: 2.

British Gypsum 15 mm Glasroc F FIRECASE two layers.

Guidance for specification option:

  • Reaction to fire: A1.
  • Thermal conductivity: 0.30 W/mk.
  • Minimum weight: 11.8 kg/m².
  • No. of layers: 2.

British Gypsum 20 mm Glasroc F FIRECASE two layers.

Guidance for specification option:

  • Reaction to fire: A1.
  • Thermal conductivity: 0.30 W/mk.
  • Minimum weight: 15.8 kg/m².
  • No. of layers: 2.

British Gypsum 25 mm Glasroc F FIRECASE two layers.

Guidance for specification option:

  • Reaction to fire: A1.
  • Thermal conductivity: 0.30 W/mk.
  • Minimum weight: 19.9 kg/m².
  • No. of layers: 2.

British Gypsum 30 mm Glasroc F FIRECASE two layers.

Guidance for specification option:

  • Reaction to fire: A1.
  • Thermal conductivity: 0.30 W/mk.
  • Minimum weight: 23.9 kg/m².
  • No. of layers: 2.

Fasteners

British Gypsum compliant fixings.

Guidance for specification option:

To required penetration.

Joint treatment

Guidance for specification option:

Consult manufacturer and insert requirements or omit.

Finish

Guidance for specification option:

Consult manufacturer and insert requirements or omit.

System accessories

Guidance for specification option:

Consult manufacturer and insert requirements or omit.

Length

3600 mm.

Width

50 mm.

FlangeDepth

70 mm.

Gauge

0.70 mm.

Manufacturer guidance

Gauge thickness.

Unit weight

1.03 kg/Lm.

Manufacturer guidance

Metal unit weight.

Sustainability data

Recyclability

Guidance for specification option:

  • Gypframe metal channels are 100% recyclable (European Waste Catalogue code is 12 01 01).
  • Gypsum based components can be fully recycled provided they are not contaminated by non-gypsum materials.

Literature

Pro-Cut Deflection Head (British Gypsum)

Pro-Cut Deflection Head (British Gypsum)

Similar products from Drywall Pro-cut Ltd

Pro-Cut 3-Sided Builder's Work Opening (British Gypsum)

Pro-Cut 3-Sided Builder's Work Opening (British Gypsum)

Pro-Cut 3-Sided Builder's Work Opening (Siniat)

Pro-Cut 3-Sided Builder's Work Opening (Siniat)

Pro-Cut 3-Sided Twin Wall Builder's Work Opening (British Gypsum)

Pro-Cut 3-Sided Twin Wall Builder's Work Opening (British Gypsum)

Pro-Cut 3-Sided Twin Wall Builder's Work Opening (Siniat)

Pro-Cut 3-Sided Twin Wall Builder's Work Opening (Siniat)

Pro-Cut 4-Sided Builder's Work Opening (British Gypsum)

Pro-Cut 4-Sided Builder's Work Opening (British Gypsum)

Pro-Cut 4-Sided Builder's Work Opening (Siniat)

Pro-Cut 4-Sided Builder's Work Opening (Siniat)

Pro-Cut 4-Sided Twin Wall Builder's Work Opening (British Gypsum)

Pro-Cut 4-Sided Twin Wall Builder's Work Opening (British Gypsum)

Pro-Cut 4-Sided Twin Wall Builder's Work Opening (Siniat)

Pro-Cut 4-Sided Twin Wall Builder's Work Opening (Siniat)

Pro-Cut Deflection Head (Siniat)

Pro-Cut Deflection Head (Siniat)