Verified by manufacturer 4 months ago
Reinforced bitumen membrane warm roof system based around the Profiles XL FireSmart Plus mineral capsheet and Thermazone Roofboard insulation.
Reinforced bitumen membrane warm roof system for use above non-combustible substrates in refurbishment and new build projects.
Reinforced bitumen membrane warm roof system based around the Profiles XL FireSmart Plus mineral capsheet and Thermazone Roofboard insulation.
Features and benefits:
Color | Grey Guidance for specification option: Charcoal or blue/grey. Blue Guidance for specification option: Blue/ grey. Green Brown Manufacturer guidanceTo match field sheet, consult manufacturer for details. |
Finish | Mineral |
Material | Bitumen Guidance for specification option: Polyester reinforced styrene butadiene styrene (SBS) modified. Polyisocyanurate (PIR) Guidance for specification option: Insulation. Manufacturer guidanceSee specification for other materials. |
Shape | Other |
Length | Bespoke |
Width | Bespoke |
Warranty description | 30 year |
Uniclass | |
CAWS | J41/10 Reinforced bitumen membrane warm deck roof covering J41/110 Built-up reinforced bitumen membrane warm deck roof covering |
Preparation | |
Horizontal work | Siplast Primer.Guidance for specification option: Low viscosity priming solution consisting of elastomeric bitumen and hydrocarbon solvent.
|
Skirtings and vertical work | As Horizontal work. |
Air and vapour control layer | |
Type | Profiles Vapour Vent XL.Guidance for specification option: Glass reinforced SBS-modified bitumen membrane with bitumen bonding stripes on the upper surface.
Characteristics:
Consult manufacturer's literature for tolerances. |
Attachment | Torch-applied.Manufacturer guidanceTo be installed in accordance with current and relevant standards such as BS 8217, BS 6229 and BS 8000-4. For further details consult the manufacturer's Flat Roofing Product Installation Guidelines or contact their technical services team. |
Insulation | |
Type | Thermazone Roofboard insulation, 25 mm thick.Thermazone Roofboard insulation, 30 mm thick.Thermazone Roofboard insulation, 40 mm thick.Thermazone Roofboard insulation, 50 mm thick.Thermazone Roofboard insulation, 60 mm thick.Thermazone Roofboard insulation, 70 mm thick.Thermazone Roofboard insulation, 80 mm thick.Thermazone Roofboard insulation, 90 mm thick.Thermazone Roofboard insulation, 100 mm thick.Thermazone Roofboard insulation, 110 mm thick.Thermazone Roofboard insulation, 120 mm thick.Thermazone Roofboard insulation, 140 mm thick.Thermazone Roofboard insulation, 150 mm thick.Thermazone Roofboard insulation, 160 mm thick.Manufacturer guidance
Tapered boards are also available. |
Fixing | Heat activation of the lozenges to the upper surface of the VCL. |
Waterproof covering | |
First layer | |
Type | TorchSafe TA Underlay.Manufacturer guidanceHeat-activated/self-adhesive glass reinforced SBS-modified bitumen membrane with vapour control stripes. For use as an underlay/ base layer.
Characteristics:
Consult manufacturer's literature for tolerances. |
Attachment | Heat activation.Self-adhesive. |
Top layer | |
Type | Profiles XL FireSmart Plus Mineral Capsheet, charcoal.Guidance for specification option: Standard. Profiles XL FireSmart Plus Mineral Capsheet, green.Guidance for specification option: Made to order, minimum order quantities may apply - consult manufacturer for details. Profiles XL FireSmart Plus Mineral Capsheet, blue/ grey.Guidance for specification option: Made to order, minimum order quantities may apply - consult manufacturer for details. Profiles XL FireSmart Plus Mineral Capsheet, brown.Guidance for specification option: Made to order, minimum order quantities may apply - consult manufacturer for details. Manufacturer guidancePolyester reinforced SBS-modified bitumen membrane with FireSmart fire retardant. For use as a torch-applied top sheet.
Characteristics:
Consult manufacturer's literature for tolerances. |
Attachment | Torch-applied. |
Detail work | |
Flashings | As Waterproof covering.FormFlash lead-free roof flashing.Guidance for specification option: Insert requirements.
Not required. |
Skirtings and upstands | TorchSafe TA Detailing Underlay and Profiles XL FireSmart Plus Mineral Capsheet.Not required. |
Welted drips | As Waterproof covering.Not required. |
Cover strips | As Waterproof covering.Not required. |
System accessories | None.Roofgard GRP Edge Trims.Guidance for specification option: A range of perimeter trims is available in sizes B50, B100 or B150, with match internal and external corners available throughout. Consult manufacturer and insert requirements. Roofgard Universal Outlets.Guidance for specification option: Insert requirements. Standard sizes: 50, 62, 80, 90 or 145 mm. Leaf grate also available. Roofgard Parapet Outlet.Guidance for specification option: Roofing outlet that complements built up roof systems allowing drainage of the roof through the parapet to an external hopper. Insert requirements: 100 mm outlet opening as standard. Leaf grate, 45° chute and extension also available. Roofgard Cable & Pipe Duct.Guidance for specification option: Provides a weatherproof sleeve for cables or tubes that penetrate through a flat roof Thermazone Roofboard Angle Fillets.Guidance for specification option: High performance rigid urethane CFC-/ HCFC-free insulation board angles for transitioning between horizontal and vertical surfaces. Roofgard Universal Cowled Telescopic Vents. |