Adhered PVC single-ply membrane water attenuation blue roofing system for cold roof constructions.

Jump to:
+44 (0)1925 658001 Website

Application

Can be laid on roofs designed for slopes with a minimum 1:100 towards the outlet. Suitable for new build and refurbishment applications on flat or pitched roofs. Can be used on concrete roof decking, plywood WBP to BS 5268-2 and BS EN 636-3 and roofing Grade OSB to BS EN 300, Grade 3.

Description

Water attenuation blue roofing system for new and existing roofs that includes Protan BPX 1.8 mm thick roofing membranes manufactured from PVC with a core of polyester reinforcement. Installed as exposed roofing, allowing rainwater to accumulate to a predefined maximum level and be stored on the roof for a certain amount of time after rainfall. Water run-off is gradually permitted into the building's drainage system before entering the drainage network. This avoids water overloading, which can result in flooding.


Features and benefits:

  • Can be laid on roofs designed for slopes with a minimum 1:100 towards the outlet.
  • Embossed surface provides a slip resistant texture.
  • Cost-effective, using the existing roof surface area.
  • Can be used with or without insulation.
  • Additional stabilizers ensure the system is resistant to temperature, UV radiation and atmospheric contamination.
  • Controls water pressure, which helps to reduce floods and flood damage.
  • Can be used on both conventional and external drains.
  • Designed to be fully adhered using a moisture-curing polyurethane adhesive. The adhesive should only be applied when the air temperature is above 5ºC.
  • SINTEF approved.
  • Suitable for new build and refurbishment applications on flat or pitched roofs.
  • Manufactured from pliable PVC reinforced with knitted polyester. The PVC contains stabilizers that provide fire resistance and make the product UV stable and resistant to both high and low temperatures. The membrane remains flexible at low temperatures, during installation and use.


Substrates:

Can be used on the following:

  • Concrete roof decking.
  • Plywood WBP to BS 5268–2 and BS EN 636–3, minimum thickness 18 mm.
  • Roofing Grade OSB to BS EN 300, Grade 3, and minimum thickness 18 mm.


Manufacturer recommends that at least one additional overflow is installed into the parapet for protection.

General information

Color

Grey

Guidance for specification option:

(Dark grey).

Finish

Anti-slip

Guidance for specification option:

Embossed surface provides an anti-slip surface texture.

Material

Guidance for specification option:

Manufactured from polyvinyl chloride (PVC) with a core of polyester reinforcement.

Uniclass

Ss_30_40_30_78 Single layer sheet cold roof covering systemsPrimary

CAWS

J42/130 Cold deck roof covering

Specification data - Single layer sheet cold roof covering systems

Waterproof covering

-

Type

Protan BPX Membrane.

Attachment

Fully-adhered.

Guidance for specification option:

Protan ProBond adhesive required.

As membrane manufacturer's recommendations.

Surface protection

Guidance for specification option:

Manufacturer recommends that at least one additional overflow is installed into the parapet for protection.

System accessories

None.

Protan Approved "BlueProof" Outlet Restrictor.

Protan Approved Fixings.

Protan Approved Leaf Guard.

Protan Approved Mastic.

Protan BP "T-Joint" Patches.

Protan Cover Strip.

Protan Grip Bar.

Protan Laminated Metal.

Protan Lightning Conductor Clips.

Protan Omega Profiles.

Protan Prefabricated D Membrane External Corners.

Protan Prefabricated D Membrane Internal Corners.

Protan Prefabricated D Membrane Pipe Collars.

Protan ProJual Rainwater Outlets.

Protan Stainless Steel Jubilee Clip.

Protan Walkway Membranes.

Product Reference

Protan BlueProof Adhered - Cold Roof System

Joints

Peel resistance/ shear resistance joints.

Guidance for specification option:

Joint welding is carried out using hot air.

Width

2000 mm.

As manufacturer's recommendations.

Thickness

1.8 mm.

Weight

≥2.1 kg/m² (plus fleece weight).

Foldability at low temperature (to EN 1107-2)

≤−30°C.

Dimensional stability (to EN 1107-2)

≥-0.5 and ≤0.5%.

Water tightness (to EN 1928)

Pass.

Resistance to tearing (EN 12310-2)

≥450/300 N.

Tensile strength (to EN 12311-2)

≥1800/1400 N/50 mm.

Elongation at break (to EN 12311-2)

≥15%.

Peel resistance of joints (to EN 12317-2)

≥150 N/50 mm.

Shear resistance of joints (to EN 12317-2)

≥1000 N/50 mm.

Water vapour resistance (to EN ISO 12572)

27 m.

Colour

Dark grey.

Third party certifications

BBA Agrément Certificate

BBA Agrément Certificate

98/3459 - Sheet 2 - SE, EX-A, BP & BPX Vacuum Roofing System