Verified by manufacturer 6 months ago
125 mm.
Health & Safety Accreditation
Certificate type
CHAS
Certificate type
Constructionline
Certificate type
ISO 9001 Quality Management
Certificate type
Impact absorbing protection rails.
Suitable for use in hospitals, nursing homes, hotels, supermarkets, schools, airports, banks and other commercial premises.
Protection rails designed to protect building fabric against accidental damage.
Features and benefits:
Approvals:
Textured Extruded Protection Products:
VOC Emissions
Yeoman Shield PVCu Falmouth Wall & Door Protection panels have been tested for VOC to ISO 16000-10:2006 Indoor air - Part 10.
The test showed the following results:
<10 µg m‑2 h‑1 for TVOC
<5 µg m‑2 h‑1 for Formaldehyde
The interpretation of these results by BRE are if all the walls (less door and window) of the 30 m3 reference room described in BS EN 16515‑2017
(with a ventilation rate of 0.5 air changes per hour) were clad with our Yeoman Shield PVCu Falmouth Wall & Door Protection Panels, the increase in TVOC in the room would
be <20 µg m‑3 for TVOC and <10 µg m‑3 for Formaldehyde and these are deemed to be low.
BREEAM Hea02 has limits of 300 µg m‑3 for TVOC and 100 µg m‑3 for Formaldehyde, so the theoretical increases in TVOC and Formaldehyde from
using our PVCu sheet are deemed as low.
Color | Black Guidance for specification option: BS 00 E 53 -stock colour Blue Guidance for specification option:
Brown Guidance for specification option: BS 08 B 29 - Stock colour Cream Guidance for specification option: BS 10 B 15 - Stock colour Green Guidance for specification option:
Manufacturer guidanceConsult manufactures colour card |
Finish | Textured |
Material | Medium density fibreboard (MDF) Aluminium PVC-U |
Length | 3500 mm |
Width | 75 mm 125 mm 200 mm |
Height | Bespoke Guidance for specification option: projection of 30 mm when fitted flat back to the wall. Projection of 88 mm stand off when fitted on standrad 60 mm spacers Manufacturer guidanceprojection |
Uniclass | |
CAWS | P20/170 Proprietary P20/75 Other proprietary items |
Product range |
Material | Vinylac, a specially formulated PVC-U. |
Fire rating | To BS EN 13501-1, class A1; BS 476: Part 7: 1997 - Class 1Y and BS 476: Part 6: 1989 + A1: 2009 - Class O. |
Finish | Stipple texture. |
Colour or pattern | Manufacturer guidanceFull range of colours available, consult manufacturer literature. |
Fixing | Screws.Guidance for specification option: Clips screw fixed to wall at 700 mm centres maximum. |
Rail width | 125 mm. |
Strengthening core | None. MDF. Aluminium. Vinylac section. |
Accessories | None. External corner – steel. External corner – Vinylac. Irregular corner – steel. Irregular corner – Vinylac. |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
Revit 2015 | 2 | |
IFC2X3 | 2 |