Verified by manufacturer 6 months ago
Maxi-Tec C stud, 90 mm
Partition system formed of Protektor MAXI-TEC 'C' studs and Siniat GTEC standard lining boards.
Internal lightweight metal partitions.
Partition system formed of Protektor MAXI-TEC 'C' studs and Siniat GTEC standard lining boards.
MAXI-TEC is an environmentally friendly steel partition profile range to actively contribute to ensure that sustainable guidelines can be reached and show how ecology, economy and ergonomics can be combined in drywall construction.
The design uses less raw material in the manufacturing process when compared to traditional drywall products, which in turn means reduced energy consumption and less CO2 emissions.
MAXI-TEC stud and track profiles are a low cost, sustainable, metal friction fit construction used to form the support frame for non-load bearing gypsum and specialist board partitions.
Finish | Smooth Guidance for specification option: Plasterboard. Galvanized Guidance for specification option: Steel. |
Material | Carbon steel Plasterboard |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Uniclass | |
CAWS | K10/30 Metal stud K10/125 Metal stud partition system |
Framing | Maxi-Tec C stud, 90 mm with U standard track, 92 mm.Guidance for specification option: Track: 30 mm deep; 3 m long as standard. Maxi-Tec C stud, 90 mm with U deep track, 92 mm.Guidance for specification option: Track: 50 mm deep; 3 m long as standard. Maxi-Tec C stud, 90 mm with U extra deep track, 92 mm.Guidance for specification option: Track: 70 mm deep; 3 m long as standard. |
Insulation | Isover Acoustic Partition Roll (APR 1200), 25 mm. |
Linings | Both sides, layers 1 & 2: Siniat GTEC Standard Board, 12.5 mm. |
Fasteners | Manufacturer's standard.Guidance for specification option: Consult manufacturer for details. |
Joint treatment | Guidance for specification option: Insert requirements. |
Finish | Gypsum plastersGuidance for specification option: Insert requirements or specify in separate clause. Plasterboard primersGuidance for specification option: Insert requirements or specify in separate clause. Finish plastersGuidance for specification option: Insert requirements or specify in separate clause. Projection plastersGuidance for specification option: Insert requirements or specify in separate clause. Other.Guidance for specification option: Insert requirements or specify in separate clause. Not required. |
System accessories | Fire rated and acoustic sealant.Guidance for specification option: Available in 300 or 600 mL. Isolation foam strip, 95 mm.Guidance for specification option: 3 mm thick; supplied in 30 m rolls as standard. Self-adhesive on one side. Can be easily applied on site or where requested at time of order can be pre-applied to the tracks ready for use on site. Acoustic foam strip, 95 mm.Guidance for specification option: 10 mm thick; supplied in 10 m rolls as standard. Self-adhesive on one side. Designed to isolate the track or stud profiles from the substrate hence reducing the possibility of flanking transmission through the frame. Installed on the underside of the track when laying out and to the back of the stud profile when starting a frame from an existing wall or flat surface. Flanking strip, 100 x 5 mm.Guidance for specification option: Supplied in 50 m rolls as standard. Self-adhesive on one side. Flanking strip with polythene skirt, 100 x 5 mm.Guidance for specification option: Supplied in 50 m rolls as standard. Self-adhesive on one side. Flanking strip, 100 x 10 mm.Guidance for specification option: Supplied in 50 m rolls as standard. Self-adhesive on one side. |
Sound insulation | To BS EN ISO 10140-2, 45 dB (C, -4 dB; Ctr, -11 dB). |
Partition thickness | 140 mm, excluding finish. Guidance for specification option: Stud width plus linings. |
Design | Guidance for specification option: Insert requirements or drawing reference/ schedule. |