Verified by manufacturer 28 days ago
UL Listed
Certificate type
P series proximity readers are for use with Net2 systems.
Installation – The reader is wired as shown on the control unit label. Be sure to avoid mounting on metal surfaces or near other proximity readers as this will affect the read range. The cable exits centrally from the back of the reader making drilling and mounting very accurate.
Operation – A token is read by holding it within close proximity of the reader. Once a token has been read the control unit looks up the access permissions of that user. Access is then granted or denied as appropriate. If access is granted the green LED flashes. If access is denied the red LED flashes.
A token is read by holding it within close proximity of the reader. Once a token has been read the control unit looks up the access permissions of that user. The control unit verifies the information and grants or denies access as appropriate. By default, all 3 LEDs are lit. If access is granted, the green LED flashes. If access is denied, the red LED flashes.’ An audible tone is emitted in both cases.
The P50, proximity readers are RFID devices that offer the contactless authentication for system users.
HID Technology has been added to the majority of readers, they and can read HID 125 kHz Proximity tokens, when licensed with an activation card. If required these readers can still be enabled to have Wiegand output, via a separate activation card.
The P38, P50, P75 and P75 Screw connector proximity readers are RFID devices that offer the convenience of contactless authentication for system users.
Features and benefits:
Color | Manufacturer guidanceAvailable in a variety of colours, consult manufacturer for details. |
Shape | Rectangle |
Length | 100 mm |
Width | 50 mm |
Height | 15 mm |
Warranty description | Five year |
Uniclass | |
CAWS | W90/356 Proximity readers W90/130 Electronic access control systems W90/363 Access control units |
Product range |
System supplier | Paxton Access Limited. |
System type | Networked stand-alone door controller. |
Equipment interconnectivity | Wired access control unit linking to readers and ancillary components; wireless data connection between access control units and proximity devices. |
Control software | Resident on the site server.Guidance for specification option: Net2. Hosted off site.Resident on the door controllers.Resident on the site PC. |
Method of authorization | Active proximity devices. |
Readers | Proximity card readers. |
Controls | Access control units. |
Door status monitoring | Door status monitoring devices. |
Rewireable installation | Required. |
Cable length | 5 m. |
Current | 170 mA. |
Extension | ≤25 m (Belden 9538). ≤100 m (Belden 9540). |
Moisture resistance | IPX7. |
Operating temperature | -35 to 66°C. |
Operating voltage | 10–14 V d.c. |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 1 | |
- | 1 |