Verified by manufacturer 14 days ago
EPD
Certificate type
A 200 mm wide framed, triple-glazed partition system.
All sectors: Commercial: Education; Healthcare; MoD; Airport; Rail; Industrial; Hospitality; Residential; Public.
Consult manufacturer for further details.
A 200 mm wide framed, triple-glazed partition system.
Features and benefits:
Please note that acoustic, fire rated and structural certification and support for Planet products and systems is available on a project-specific basis. Please contact the specification team directly for further information.
Color | Other Guidance for specification option: Polyester powder-coated or anodized. Silver Guidance for specification option: Polished or linished. |
Finish | Polished Anodized Guidance for specification option: Etched and anodized. Powder-coated Guidance for specification option: Polyester powder-coated. Other Guidance for specification option: Linished. |
Material | Aluminium Guidance for specification option: 6063 T6. Glass |
Shape | Rectangle Other Manufacturer guidanceTo suit project requirements; consult manufacturer for further details. |
Length | Bespoke |
Width | 200 mm |
Height | Bespoke |
Warranty description | Manufacturer guidanceDealt with on a project specific basis as part of the O&M process; consult manufacturer for details. |
Uniclass | |
CAWS | K30/130 Relocatable partition system K30/10 Relocatable partition system |
Product range |
Third-party certification | ISO 9001-UKAS (Quality); ISO 14001-UKAS (Environmental); Constructionline-Gold; Acclaim (SIPP); Achilles (Building confidence, SIPP); EPD - material accreditation & compliance; FIS Member; Considerate Construction; FORS Bronze; Build Profile.Guidance for specification option: EPD - material accreditation & compliance: Consult manufacturer for details (glass, PPC, aluminium, timber, ironmongery, waste, adhesive and more). |
Unit size | |
Thickness | 200 mm. |
Partition height (nominal) | Manufacturer guidanceInsert requirements. For partitions over 3000 mm high, consult with manufacturer. |
Width (nominal) | Manufacturer guidanceInsert requirements. For partitions over 1200 mm wide, consult with manufacturer. |
Deflection allowance (maximum) | |
Head | No deflection; 27 mm deep x 200 mm wide channel. |
Floor | Manufacturer guidanceConsult with manufacturer for system weight. |
Verticals | 27 mm deep x 200 mm wide channel. |
Panel partition type | Triple glazed. |
Framing, fixing points and joints | Extruded aluminium sections.Guidance for specification option: Junctions and corners: not suitable. |
Joint treatment | |
Type | Triple glazed. |
Glazed panels | |
Type | One layer 10.8 mm annealed acoustic laminate.One pane 10 mm heat soaked toughened, one layer of 10.8 annealed acoustic laminate - low iron option.Manufacturer guidanceConsult manufacturer to ensure compliance with test/ assessment data. |
Integral blinds | Not required.Tilt/ turn venetian blinds.Guidance for specification option: Battery powered, remote control. Consult manufacturer for details. |
Additional features | None.Double glazed/ boarded tech panel to incorporate room booking systems, access control and other electronics. |
Door arrangement | |
Type | Manufacturer guidanceConsult manufacturer for options and insert requirements. |
Door frames | Manufacturer guidanceConsult manufacturer for options and insert requirements. |
Ceiling | |
Type | Manufacturer guidanceConsult manufacturer for interface detail and insert requirements. |
Method of support | Manufacturer guidanceConsult manufacturer for support detail and insert requirements. |
Perimeters, skirtings, sills | 27 mm-deep x 200 mm-wide two-part aluminium channel. |
Seals | Clear perimeter compression seals.Black perimeter compression seals. |
Other features | Manufacturer guidanceConsult manufacturer and insert requirements or leave blank. |
Manifestation | Allowance of 2 nr rows 50 mm dots or square (minimum) Opal Frost. Guidance for specification option: Insert requirements. Artwork and custom manifestation to client design. Guidance for specification option: Insert requirements. Manufacturer guidanceTo architects choice and in accordance with the requirements of Approved Document K. |
StrengthGrade | Manufacturer guidanceConsult with the manufacturer to ensure the system complies with current regulations BS 5234:1992 non load-bearing screens not protecting a change in adjacent floor level of >380 mm. For glass load resistance criteria;
Building regulations Part N (BS 6262 & BS EN 12600) + InsStucEng publication “structural use of glass in buildings” insert as required:
BS 6180:2011 barriers in and about buildings for Atria or protected change in adjacent floor level of >380 mm. Horizontal uniformly distributed line load 1100 mm above FFL (glass deflection limited to L/65 or 25 mm, whichever is less relative to glass fixings). Structural glass based on line-load and attendant UDL + point load, insert as required:
|
Acoustic performance | 64 dB Rw. |
Partition | Frameless glass - triple glazed. |
Fasteners | To manufacturer's specification, type, length and frequency to suit substrates. |
Joint treatment | Fixed panels. |
Samples required | Manufacturer guidanceConsult with manufacturer. |
Finish/ Colour | Polyester powder-coated, RAL. Guidance for specification option: Insert colour requirement. Polished and chemically brightened. Linished and chemically brightened. Etched and anodized. Guidance for specification option: Insert requirement. |
Contains Red List materials | No Guidance for specification option: No substance on the “Candidate List of Substances of Very High Concern for authorisation” derived under REACH is present either above the limits for registration with the European Chemicals Agency or in excess of 1 weight–% of the product. |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Recyclability | 100% Guidance for specification option: Aluminium and glass. |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | Manufacturer guidance17–28% for glass. 70% for aluminium. |