Verified by manufacturer 7 months ago
T-EI90/47-3 SWS
EPD
Certificate type
ISO 9001 Quality Management
Certificate type
Certifire Certificate
Certificate type
A range of high-performance fire safety glass certified for seamless joint applications.
For use in glazed wall applications in timber, steel or aluminium frames.
A range of fire safety glass certified for butt-joint applications, providing integrity and heat insulation for 30, 60 and 90 minutes (EI classification). No vertical frame profiles required, providing visually appealing seamless partitions between rooms and corridors.
Features and benefits:
Color | Clear |
Finish | Glazed |
Material | Glass |
Shape | Rectangle Square Other |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | Ten year |
Uniclass | |
CAWS | L20/25 Wood panelled doors H10/115 Patent glazing L40/510 Fire-resistant channel glazing – solid section channel L10/45 Rooflights L10/33 Proprietary windows L10/20 Steel windows L10/15 Wood windows L10/10 Wood windows L20/20 Wood flush doors L20/410 Wood doorsets L20/250 Wood panelled doors L20/480 Doorsets L10/560 Glazed screen system L10/510 Glazed wood screens L10/480 Roof windows L10/460 Rooflights L10/390 Proprietary windows L10/310 Steel windows L10/210 Wood windows L40/65 Fire-resistant tape/ Strip glazing L40/75 Fire-resistant channel glazing – solid section channel L40/515 Fire-resistant channel glazing – plastics/ elastomeric channel L40/80 Fire-resistant channel glazing – plastics/ elastomeric channel L20/280 Doors L20/270 Wood doors L20/45 Doors L20/420 Wood doorsets L20/30 Wood doors H11/110 Curtain walling L20/230 Wood flush doors L20/55 Doorsets L40/505 Fire-resistant tape/ Strip glazing |
Third-party certification | Approved by Certifire UK and Efectis, France; CE/UKCA certificate of conformity: 1812-CPR-1643. |
Laminate glass type | Safety.Guidance for specification option: Ug value, to EN 673: 4.6 W/m²K; G-value, to EN 410: 0.56. |
Thickness | 47 mm.Guidance for specification option: -1/+3 tolerance. |
Outer leaf | Toughened safety glass. |
Mid-leaf | Toughened safety glass. |
Inner leaf | Toughened safety glass x2. |
Interlayer to glass leaves | Manufacturer's standard (three interlayers). |
Body colour | Clear. |
Performance requirements | |
Fire resistance | |
Integrity | E 90. |
Insulation | I 90. |
Light | Transmittance: 72%. |
Impact resistance | To BS EN 12600: 1B1. |
Security | To EN 356: P1A. |
Worked finish | |
Design | Structural wall/ butt-joint.Angled butt-joint. |
Sound reduction | 46 dB (minimum). |
Reaction to fire | A2-s1, d0. |
Sheet size | Manufacturer guidanceInsert requirements, 300–1800 x 400–3500 mm. |
Weight | 96 kg/m². |
TemperatureRange | -10/+45°C. |
Contains Red List materials | No |
Country of material origin | Europe Manufacturer guidanceManufactured in UK and in France |
Country of product manufacture | United Kingdom |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 61 kg CO₂ eq/m² Manufacturer guidanceValue for T-/24-2 SWS |
EPD
Environmental Product Declaration
ISO 9001 Quality Management
Quality Management System - ISO 9001:2015
Certifire Certificate
Certifire Certificate of Approval CF 5227 - Pyroguard T EW
Certifire Certificate
Certifire Certificate of Approval CF 5204 - Pyroguard T-EI
Certifire Certificate
Certifire Certificate of Approval CF 437 - Pyroguard EI