NBS Source
I'm a manufacturer
Compare variants

Raybloc® Doorset (Standard)

Verified by manufacturer 28 days ago

Single Doorset

Raybloc (X-Ray Protection) Ltd Variant:
Third party certifications:
  • ISO 9001 Quality Management

    Certificate type

Raybloc® Doorset offers scatterproof radiation shielding, ensuring safety in controlled areas. This product covers laminate, veneer, and painted options. PVC is also available (see product page).

Jump to:
BOS
+4401902 633383 Website

Application

Raybloc's lead-lined doors are suitable for controlled areas in various industries, including medical facilities, research laboratories, nuclear power plants, and industrial testing facilities. Wherever radiation protection is critical, our X-Ray door offers peace of mind and optimal safety.

Description

A doorset solution for radiation protection in critical environments, providing an aesthetic look and finish. Crafted with precision in-house manufacturing methods with over 30 years of experience, the lead lined X ray door set combines innovative design and advanced radiation shielding technology to deliver exceptional performance, ensuring radiation protection to the highest quality.


Designed for maximum functionality and durability, the X-ray door withstands rigorous conditions with its sturdy core and robust construction. It offers unparalleled structural integrity, ensuring reliable performance even in high-risk radiation environments. Its bespoke lead lining effectively absorbs and attenuates harmful radiation, safeguarding individuals and ensuring facility integrity.


Safety is a high priority, with optional features like lead-lined vision panels, fire-rated protection, various additional ironmongery, and customisable flush-mounted eye-level warning lights. These enhancements provide comprehensive protection and a secure working environment.


Raybloc's commitment to quality is evident through rigorous testing and compliance with industry regulations. Our lead-lined X ray door set exceeds expectations in performance, reliability, and longevity. When it comes to radiation protection, trust Raybloc. Our Radiation Protective Lead-Lined Doorset is the embodiment of our expertise and dedication to safety.


Features and benefits:

  • Bespoke to fit any structural opening.
  • Custom-sized vision panels.
  • Customisable flush-mounted warning light (eye level).
  • Standard lead equivalence from 1.32 mmPb (Code 3) to 20 mmPb.
  • Additional ironmongery such as door closers, kick-plates and more.
  • Available with hardwood frames and stainless steel frames.
  • Fire resistant for up to one hour (test evidence available).
  • 10-year material and workmanship warranty.
  • All timber products purchased and used by Raybloc (X-ray Protection) Ltd are FSC-certified for sustainability.
  • Also available in PVC encapsulated (see Raybloc page for more information).
  • Manufactured in the United Kingdom.

General information

Finish

Painted

Laminated

Veneered

Wood grain

Woodgrain

Show more

Material

Wood

Lead

Glass

Steel

Shape

Rectangle

Length

Bespoke

Width

Bespoke

Height

Bespoke

Warranty description

Ten year

Manufacturer guidance

10-Year Material and Workmanship Guarantee

10-Year Radiation Shielding Warranty when installed by Raybloc

Uniclass

Pr_30_59_24_97 Wood doorsetsPrimary

CAWS

L20/480 Doorsets

L20/55 Doorsets

L20/410 Wood doorsets

Specification data - Wood doorsets

Configuration

Single-leaf.

Doorset size

-

Manufacturer guidance

As required to suit the requested structural opening.


Performance

-

Fire resistance

-

Integrity

Non-fire rated.

FD30.

Guidance for specification option:

FD30s - 30 minutes' fire and smoke resistance.

FD60.

Guidance for specification option:

FD60s - 60 minutes' fire and smoke resistance.

Insulation

Non-fire rated.

FD30.

Guidance for specification option:

FD30s - 30 minutes' fire and smoke resistance.

FD60.

Guidance for specification option:

FD60s - 60 minutes' fire and smoke resistance.

Acoustic performance

-

Manufacturer guidance

0-35 dB. Consult manufacturer for details and insert requirements if applicable.

Strength and durability

Mechanical / Severe Duty Rating – exceeding the minimum requirements of DD171 and BSEN 1192 for 'Severe Duty' performances.

Thermal

-

Manufacturer guidance

Door Core - Building regulations approved document ‘L’. Using BS EN 150 10077-2:2003 – Calculation of thermal transmittance.

Intruder resistance

-

Minimum requirement

To PAS 24.

Guidance for specification option:

Door cores have been tested to PAS 23 – 1:1999 and PAS 24 – 1:1999 general performance and enhanced security performance requirements.

Frame

-

Material

Hardwood.

Species

Beech.

Maple.

Oak.

Sapele

Walnut.

Perimeter seals or inserts

Acoustic seal.

Fire and smoke seal.

Finish

Ash.

Beech.

Maple.

Oak.

PVC encapsulated.

Primer painted.

Sapele.

Walnut.

Door leaf

-

Thickness

44 mm.

54 mm.

Core

FLAMEBREAK FF630 - 44 mm solid core with 6 mm MDF face, lead-lined.

FLAMEBREAK FF660 - 54 mm solid core with 6 mm MDF face, lead-lined.

Panel details

Half-height PVC face.

Full-height PVC edge (vertical edges).

Half-height PVC frame.

Facings

MDF board.

Species

Mixed tropical hardwood.

Lippings

5 mm hardwood.

Perimeter seals

Smoke/ acoustic.

Glazing

-

Type

Radiation protective lead glass (to suit lead equivalence of door).

Guidance for specification option:

Custom size as requested. (Standard Sizes 300 x 300mm Square, 250 x 750mm Rectangle).

Manifestation

Standard.

LCD switchable glass.

Beading

-

Type

Lead-lined hardwood beading.

Flush-fitted.

Material

Hardwood.

Door accessories

Interstitial blinds.

Laser blackout interstitial blinds.

Hardware

Dormakaba TS 93.

Fire Disks.

Flush Bolts.

GEZE TS4000E.

GEZE TS4000S.

H101 Royde &Tucker hi-load lift off hinges- stainless steel.

Handles.

Kick Plates.

Architraves

-

Material

Hardwood - lead lined to the controlled area side, 70 x 15 mm (5 mm chamfer to the internal edge).

MDF - lead lined to the controlled area side, 70 x 15 mm (5 mm chamfer to the internal edge).

Finish

Beech.

Maple.

Oak.

Sapele

Walnut.

Primer.

Lead lining thickness

-

Manufacturer guidance

1.32 mm Pb (code 3) to 20 mm Pb to suit specified requirements of the RPA report. Insert requirements.

Profile

Standard profile: 65 mm x wall thickness.

Rebate size

50–75 x 25 mm.

Sustainability data

Contains Red List materials

Yes

Guidance for specification option:

Lead

Country of product manufacture

United Kingdom

Material

Wood

Lead

Glass

Steel

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
Revit
-

1

IFC
-

1

Third party certifications

ISO 9001 Quality Management

ISO 9001 Quality Management

ISO 9001:2015

Literature

Raybloc Lead-Lined Doorset Leaflet

Raybloc Lead-Lined Doorset Leaflet

Fujifilm Bedford | A Photographic Study

Fujifilm Bedford | A Photographic Study

Raybloc Radiation Protective Lead-Lined Doorset - Specification

Raybloc Radiation Protective Lead-Lined Doorset - Specification

Case studies

Bronglais Hospital Aberystwyth

Bronglais Hospital Aberystwyth

Singleton Hospital Swansea

Singleton Hospital Swansea