Verified by manufacturer 20 days ago
KB-200
ISO 9001 Quality Management
Certificate type
Internally insulated kerb upstand to suit bespoke roof opening, compatible with bespoke ROOFBOX® M roof cabinets.
Can be used where an upstand is required around a roof opening, including rooflights, lantern lights and roof hatches, and corresponding bespoke ROOFBOX® M roof cabinets.
Internally insulated kerb upstand to suit bespoke roof opening, compatible with bespoke ROOFBOX® M roof cabinets.
Features and benefits:
Color | Grey Other |
Finish | Powder-coated |
Material | Aluminium Guidance for specification option: 2.0 mm-thick, 5251 grade. Polyisocyanurate (PIR) Guidance for specification option: Insulation. |
Shape | Rectangle |
Length | Bespoke |
Width | Bespoke |
Height | 200 mm 375 mm 450 mm 600 mm |
Warranty description | Ten year |
Uniclass | |
CAWS | Q37/130 Extensive green roof Q37/120 Simple intensive green roof Q37/110 Intensive green roof J41/135 Single-layer reinforced bitumen membrane cold deck roof covering J41/130 Built-up reinforced bitumen membrane cold deck roof covering J41/125 Single-layer reinforced bitumen membrane inverted roof covering J41/120 Built-up reinforced bitumen membrane inverted roof covering J41/12 Reinforced bitumen membrane cold deck roof covering J31/130 Inverted roof coating J31/110 Cold deck roof coating J31/12 Inverted roof coating J31/5 Cold deck roof coating L20/630 Hatches L10/45 Rooflights L10/460 Rooflights |
Material | 2 mm-thick 5251 grade aluminium.Guidance for specification option:
|
Insulation | 100 mm-thick foil faced polyisocyanurate (PIR).Guidance for specification option: U-value: 0.022 W/m·K. Manufacturer guidanceFurther insulation options are available to provide enhanced U-values and fire ratings. Consult manufacturer for details. |
Factory finish | |
Coating | Polyester powder-coated. |
Colour | RAL 7047.Guidance for specification option: Standard. RAL, bespoke.Guidance for specification option: Insert requirement. |
Film thickness (minimum) | Manufacturer's standard. |
Dimensions | |
Roof opening | Manufacturer guidanceInsert requirements. |
Integral kerb | 200 mm high.Guidance for specification option: Width: 115 mm. Fixing flange: 50 mm. |
Verification | |
Submittals | Manufacturer guidanceSee generic guidance and insert requirements. |
Timing | Manufacturer guidanceSee generic guidance and insert requirements. |
Maximum live load | 5.0 kN/m. |
Fire performance | Class 1 (BS 476, Part 7); Euroclass F (BS EN 13501-1). |
Contains Red List materials | No |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Material | Aluminium Guidance for specification option: 2.0 mm-thick, 5251 grade. Polyisocyanurate (PIR) Guidance for specification option: Insulation. |
Recyclability | Recyclable at end of life |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 50 % |
ROOFBOX® K1 - Roof Upstands Kerb
ROOFBOX® K2 - Roof Upstand Kerb
ROOFBOX® K3 - Roof Upstand Kerb
ROOFBOX® K4 - Roof Upstand Kerb
ROOFBOX® K5 - Roof Upstand Kerb
ROOFBOX® K6 - Roof Upstand Kerb
ROOFBOX® M Bespoke - Roof Service Penetrations Unit
ROOFBOX® M1 - Roof Service Penetration Unit
ROOFBOX® M2 - Roof Service Penetration Unit
ROOFBOX® M3 - Roof Service Penetration Unit