Verified by manufacturer 8 days ago
BRE Certificate
Certificate type
ISO 9001 Quality Management
Certificate type
Rooflight glazing system.
Suitable for commercial, public, heritage, listed building, historic, museums, galleries, offices, universities, residential, schools, colleges, atriums and domestic buildings.
TG50 System
ThermGard ALM100
Color | Silver Clear Guidance for specification option: Infill. Other Guidance for specification option: Polyester powder coated frame to any RAL or BS colour. |
Finish | Glazed Mill Powder-coated |
Material | Aluminium Stainless steel Steel PVC Lead |
Shape | Rectangle |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Uniclass | |
CAWS | H10/115 Patent glazing L10/45 Rooflights L10/460 Rooflights |
Rooflight | Framed rooflights. |
Installation fasteners | Stainless steel, grade A2. |
Trim | Guidance for specification option: Consult manufacturer and insert requirements or omit. |
Filler | Guidance for specification option: Consult manufacturer and insert requirements or omit. |
Hardware | Guidance for specification option: Consult manufacturer and insert requirements or omit. |
Operation | Manual. |
System accessories | Guidance for specification option: Consult manufacturer and insert requirements or omit. |
Design | Guidance for specification option: Insert drawing/ reference. |
Box bar | Box bar 2. Box bar 3. Box bar 4. Manufacturer guidanceConsult manufacturer for further details. |
Combustibility | Non-combustible. |
Non-fragility rating | Required. Guidance for specification option:
Not required. |
Flashings | Aluminium. Lead. |
PitchAngle | 5° (minimum). |
Air permeability | 0.71 m³/h.m² at 600 Pa, Class 4. Guidance for specification option: To BS EN 12207: 2016. |
Weather performance | Weather-tight to Class E1650. Guidance for specification option: To BS EN 12208. |
Capping | Extruded aluminium alloy, 6063-T6. |
Fittings | Extruded aluminium alloy, 6063-T6. |
Pressure plate | PVC. Manufacturer guidanceCo-extruded. |
Thermal break | PVC. Manufacturer guidanceCo-extruded thermal barrier. |
Gaskets | PVC. |
Form | Flat. |
Fire resistance | External fire exposure: Class AA. Guidance for specification option: To BS 476. |
Reaction to fire | Surface spread of flame: Class 1. |
FrameMaterial | Extruded aluminium alloy, 6063-T6. |
Coating | Mill finish. Guidance for specification option: Standard. Polyester powder-coated. Manufacturer guidanceFrame finish. |
Colour | RAL. Guidance for specification option: Polyester powder coated: Insert RAL or BS colour code. Manufacturer guidanceFrame finish. |
Type | Double glazed, heat soak test (HST) toughened clear glass (laminated softcoat glass). Guidance for specification option: Thermal transmittance (U-value): 1.2 W/m²·K. Double glazed, heat soak test (HST) toughened neutral solar control glass 70/30 (laminated clear glass). Guidance for specification option: Thermal transmittance (U-value): 1.0 W/m²·K. Triple glazed, heat soak test (HST) toughened neutral solar control glass 70/30 (laminated softcoat, clear glass). Guidance for specification option: Thermal transmittance (U-value): 0.6 W/m²·K. Manufacturer guidanceGlazing or infill.
|
Construction | Double skin. Triple skin. Manufacturer guidanceGlazing or infill. |
Colour | Clear. Manufacturer guidanceGlazing or infill. |
Contains Red List materials | No |
Country of material origin | Europe |
Country of product manufacture | United Kingdom |
Recyclability | Approximately 85% of the product is aluminium which 100% recyclable, remaining 15% is gaskets and thermal liners. |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 35 % |