Verified by manufacturer 2 months ago
Schöck Bole® Type O
UK Technical Assessment (UKTA)
Certificate type
Punching shear reinforcement.
Perfect solution to provide punching shear reinforcement in flat slabs.
Schöck Bole® is a punching shear reinforcement consisting of double headed studs with spacing bars to secure correct positioning. The various types of Schöck Bole® facilitate time-saving installation in different situations. Schöck Bole® type O is mounted after and type U before installation of the top and bottom slab reinforcement.
Features and benefits:
Color | Grey |
Material | Carbon steel |
Uniclass | |
CAWS | E30/240 Proprietary prefabricated reinforcement |
Application | Shear heads. |
Diameter | 10 mm.Guidance for specification option: 30 mm head diameter, 34.4 kN tensile yield strength. 12 mm.Guidance for specification option: 36 mm head diameter, 49.2 kN tensile yield strength. 14 mm.Guidance for specification option: 42 mm head diameter, 67 kN tensile yield strength. 16 mm.Guidance for specification option: 48 mm head diameter, 87.4 kN tensile yield strength. 20 mm.Guidance for specification option: 60 mm head diameter, 136.6 kN tensile yield strength. 25 mm.Guidance for specification option: 75 mm head diameter, 213.6 kN tensile yield strength. |
Third party certification | European Technical Assessment - ETA-13/0076. |
Type | O. Guidance for specification option: Punching shear reinforcement Schöck Bole® type O is mounted after installation of the top and bottom slab reinforcement. This approach to installation is particularly recommended for slab thicknesses up to 30 cm and moderate reinforcement requirements. The product is supplied ready for installation; no further parts are needed for assembly. Schöck Bole® type O is suitable for installation on site.
|
Number | Manufacturer guidanceInsert requirement. |
Anchor length | Manufacturer guidanceInsert requirement, available 130–400 mm dependent on anchor diameter. |
Anchor spacing | Manufacturer guidanceInsert requirement. |