Siderise Open State Cassette Inserts (OSCI) are designed for use in Cassette Panel Cladding Systems.
Siderise Open State Cassette Inserts (OSCI) can be used both horizontally and vertically as part of a cladding system. They are applied directly to the internal surface of the cassette panel to simplify the detailing and installation of adjacent cavity barriers and/or to ensure that the ventilation air gap is dimensioned within permissible limits.
Siderise Open State Cassette Inserts (OSCI) are positioned parallel and aligned centrally to Siderise 'RH' or 'RV' Cavity Barriers, taking into account the specification of the cladding system assembly. Typically, this requires consideration of the specification and configuration of the cladding panels, the positioning of the support rails or similar steelwork, and/or hook-on or bracket arrangements for panel support.
Siderise Open State Cassette Inserts (OSCI) should not be used in conjunction with cavity barriers from another manufacturer or type.
Siderise Open State Cassette Inserts (OSCI) products are manufactured from strips of high density non-combustible stonewool (Class A1) with a foil-facing on two sides. One side has an additional high-performance modified acrylic pressure-sensitive adhesive with strippable film.
Siderise Open State Cassette Inserts (OSCI) are available in a range of sizes and are selected according to the type and size of the corresponding Siderise Open State Cavity Barrier specification on a project basis.
Features and benefits:
Color | Silver Guidance for specification option: Silver aluminium top and bottom facings Other Guidance for specification option: Solid, green-brown exposed edges |
Finish | Foil Guidance for specification option: Foil. |
Material | Stonewool |
Shape | Rectangle |
Length | 1220 mm |
Width | Manufacturer guidancePlease see product width |
Height | Manufacturer guidanceThe depth of the OSCI can be variable with a minimum depth of 30mm. Other OSCI depths can be made available, please contact the manufacturer. Please see product 'Depth' |
Uniclass | |
CAWS | H92/776 Thermal insulation P12/360 Mineral wool rigid batts P12/40 Mineral wool rigid batts |
Product range |
Thickness | 40 mm. |
Edges | Square. |
Thermal conductivity (maximum) | 0.043 W/m·K. |
Fire performance | To EN 13501-1, Class A2-s1, d0. |
Width | 100 mm. |
Length | 1220 mm. |
Contains Red List materials | No |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Material | Stonewool |
Recyclability | Recyclable |
Expected Life | 60 year Guidance for specification option: Only when used in combination with Siderise Cavity Barriers for Rainscreen Cladding but particular attention must be applied to the fixing system as detailed below: • Keeping the product dry during both storage and installation • Following the method of attaching the system detailed in our installation instructions • Ensuring that the top and bottom of the ‘OSCI’ is sealed with lengths of Siderise RFT120 aluminium jointing tape to ensure a weather tight seal • If appropriate to the project system and panel construction, use additional mechanical retention |