Verified by manufacturer 6 months ago
Sika® CarboDur® M, type 614
Carbon fibre plates for strengthening a range of structures.
Sika® CarboDur® systems are used to improve, increase or repair the performance and resistance of structures for:
Consult manufacturer's literature for further details.
Structure types:
Carbon fibre plates for strengthening a range of structures.
Features and benefits:
Sika® CarboDur® M and CarboDur® S plates:
Sika® CarboDur® S NSM:
Sika® CarboDur® Plate UHM:
Color | Black |
Finish | Other |
Material | Carbon fibre Guidance for specification option: Carbon-fibre-reinforced with an epoxy matrix. |
Shape | Other |
Width | 10 mm 15 mm 20 mm 50 mm 60 mm |
Height | 1.2 mm 1.4 mm 2.5 mm 2.6 mm 3 mm |
Uniclass | |
CAWS | E30/240 Proprietary prefabricated reinforcement F30/265 Support system G10/135 Hollow steel sections G12/330 Proprietary metal members G20/230 Structural softwood (strength class not specified) G20/210 Structural softwood (graded direct to strength class) G20/250 Structural hardwood (graded direct to strength class) G20/260 Structural hardwood (strength class not specified) G20/345 Proprietary structural wood composite G20/336 Structural wood composite G20/7 Structural hardwood G20/5 Structural softwood G10/17 General steel sections G20/17 Structural wood composite G12/30 Proprietary |
Accessories | Guidance for specification option: Consult manufacturer for options and insert requirements or omit. |
Form | Carbon fibre reinforced polymer with an epoxy matrix, black. Guidance for specification option: Fibre volume content: >68%. |
Width | 60 mm. |
NominalThickness | 1.4 mm. |
Tensile strength | Laminate, to EN 2561: 3500 MPa (mean). Guidance for specification option: 5% fractile value: 3200 MPa. |
Modulus of elasticity | Laminate, to EN 2561: 210 000 MPa (mean). Guidance for specification option: 5% fractile value: 205 000 N/mm². |
Elongation at break | Laminate, to EN 2561: 1.7% (mean). |
Area | Cross section: 84 mm². |
Fixing | Sikadur®-30 epoxy resin-based adhesive. Guidance for specification option: For normal temperatures during application and/or service. Other. |