EI60 Shaftwall System with 25 mm glass mineral wool insulation, classified to EN 13501-2:2016.

General information

Color

Pink

Finish

Smooth

Material

Plasterboard

Steel

Glass mineral wool

Width

Bespoke

Height

Bespoke

Warranty description

Lifetime

Guidance for specification option:

Etex Building Performance Limited offers both a comprehensive Lifetime System Warranty (excl. Aqua Board and Weather Defence) and 10 Year Warranty (Incl. Aqua Board and Weather Defence). For full details see the full Warranty and Proprietary Systems Policy at www.siniat.co.uk/knowledge-centre/. Etex Building Performance Limited warrants to the purchaser that the Siniat Plasterboard Solutions (“Systems”) as originally designed, built and unaltered will perform to the original laboratory performance parameters as set out in the Siniat Drywall Manual and other relevant literature as published by Siniat. The system must be constructed solely with the proprietary products and components as supplied by Siniat. The system must be installed by a professional installer in accordance with: the Siniat Drywall Manual; this specification document; CAD drawings; advice; and all relevant and applicable construction standards and regulations. 

Uniclass

Ss_25_10_30_35 Gypsum board partition systemsPrimary

CAWS

K10/125 Metal stud partition system

K10/30 Metal stud

Specification data - Gypsum board partition systems

System performance

All Siniat systems should be constructed to BS 8000-8:2023 'The Standard for Workmanship on construction sites - Design and installation of dry lining systems. Code of practice.'

Framing

60 mm Siniat CH Studs CHS1960/B at 600 mm centres.
60 mm Siniat E Studs ES1960/B.
Head track: 62 mm Siniat U Track Deep Flange UDT62/P.
Base track: 62 mm Siniat U Track Flange UT62/Rx.

Manufacturer guidance

All Siniat CH-Studs and E-Studs to be a minimum 25 mm shorter than floor to ceiling height or by deflection amount, whichever is greater. 

Insulation

Glass mineral wool, 25 mm.

Linings

Face A Plasterboard Linings - Inner Layer: 19 mm Siniat Fire Core Board.
Face B Plasterboard Linings - Inner Layer: 12.5 mm Siniat Fire Board.
Face B Plasterboard Linings - Outer Layer: 12.5 mm Siniat Fire Board.

Manufacturer guidance

Shaft side lining: 19 mm Siniat Fire Core Board.

Corridor/room side lining: 12.5 mm Siniat Fire Board.

Fasteners

Face B Inner Layer Fixing: 25 mm Siniat Self Tapping Screws at 600 mm centres.
Outer Layer Fixing: 38 mm Siniat Self Tapping Screws at 300 mm centres.

Joint treatment

Decorative.

Guidance for specification option:

Outer layer room side boards to be taped and jointed using appropriate Siniat compounds and tape.

Non-decorative.

Guidance for specification option:

Outer layer room side boards to be taped and jointed using appropriate Siniat compounds and tape to at least first stage (bedding).

System accessories

Siniat Flat Strap FS50/Rx.

Guidance for specification option:

For use where partition height exceeds board height; to be fixed behind all horizontal joints to provide substrate for board fixing.

Fire resistance

To EN 1364-1: 60 minutes.

Partition height

Cold state: 4800 mm.
Fire state: 3000 mm.

Sound insulation

46 dB.

Duty rating (to BS 5234-2)

Severe.

Thickness:

85 mm.

Sealing (joints and penetrations)

Siniat Intumescent Acoustic Sealant.

Guidance for specification option:

Apply continuous beads of Siniat Intumescent Acoustic Sealant around the perimeter of the framing or to the edge of outer layers of board, ensuring that all air-paths are sealed. 


All penetrations should use supporting constructions detailed in the Siniat Drywall Manual unless superseded by specific test information. For combined, warrantied performance specify FSi fire-stopping products. For cPVC pipe sealing, use FSi PYROPRO® HPE Sealant in place of Siniat Intumescent Acoustic Sealant.

System code

CH60B-19FC#212F

Standards

All products are CE marked and UKCA marked in accordance with Construction Products Regulation where relevant standards or European Technical Approvals exist. All boards to conform to BS EN 520 or alternative standard where appropriate. Metal framing components are hot-dipped galvanized steel to BS EN 10346. Metal sections rolled to BS EN 10162. Metal studs, tracks and accessories conform to BS EN 14195 where required. Drywall screws conform to BS EN 14566.

Sealer coat

Siniat Drywall Sealer.

Sustainability data

Country of material origin

Spain

Guidance for specification option:

Applies to the bulk material (gypsum) only. Other components are from other countries. Consult manufacturer for details.

Country of product manufacture

United Kingdom

Manufacturer guidance

UK applies to the majority of manufacture but a small percentage of finished items are imported. Contact manufacturer for details.

Material

Plasterboard

Steel

Glass mineral wool

Embodied carbon

A1-A3 (production stage) as defined in BS EN 15804

-

Manufacturer guidance

Latest EPD information available from: https://www.siniat.co.uk/en-gb/documentation/

Recyclability

Gypsum and metal components can be recycled depending on the segregation of all materials.

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

-

Manufacturer guidance

Gypsum average 33.5% and metal average 17%.

BIM objects

Platform Compatible Version
Revit
-

1

Third party certifications

BS EN 13501-2:2023

Fire classification report EUI-24-000051

Similar products from Siniat

Siniat A1 Shaftwall System – CH14B-19WD#312WD

Siniat A1 Shaftwall System – CH14B-19WD#312WD

Siniat A1 Shaftwall System – CH90B-19WD#312WD

Siniat A1 Shaftwall System – CH90B-19WD#312WD

Siniat EI120 Shaftwall System – CH14B-19FC#315F-25G

Siniat EI120 Shaftwall System – CH14B-19FC#315F-25G

Siniat EI120 Shaftwall System – CH60B-19FC#315F-25G

Siniat EI120 Shaftwall System – CH60B-19FC#315F-25G

Siniat EI120 Shaftwall System – CH90B-19FC#315F-25G

Siniat EI120 Shaftwall System – CH90B-19FC#315F-25G

Siniat EI60 Shaftwall System - CH60B-19FC#212F

Siniat EI60 Shaftwall System - CH60B-19FC#212F

Siniat EI60 Shaftwall System – CH14B-19FC#212F

Siniat EI60 Shaftwall System – CH14B-19FC#212F

Siniat EI60 Shaftwall System – CH14B-19FC#212F-25G

Siniat EI60 Shaftwall System – CH14B-19FC#212F-25G

Siniat EI60 Shaftwall System – CH90B-19FC#212F

Siniat EI60 Shaftwall System – CH90B-19FC#212F

Siniat EI60 Shaftwall System – CH90B-19FC#212F-25G

Siniat EI60 Shaftwall System – CH90B-19FC#212F-25G