SitaStandard Rainwater Outlet - Thermally Insulated Roof Outlet

Verified by manufacturer 3 months ago

Vertical

Sita Bauelemente GmbH Variant:
Third party certifications:
  • BRE Certificate

    BRE Certificate

    Certificate type

  • ISO 9001 Quality Management

    Certificate type

  • TUV - Safety and Quality Report

    Certificate type

  • EPD

    EPD

    Certificate type

Range of thermally insulated roof outlets with bodies made of rigid polyurethane integral foam.

Jump to:
BOS
07402239777 Website

Application

For main and emergency drainage to DIN EN 12056-3 and DIN 1986-100 for large used and unused flat roofs.

Description

Range of Thermally Insulated Roof Outlets featuring bodies made of rigid polyurethane, designed for both main and emergency drainage applications.


The SitaStandard Vertical outlet is constructed from thermally insulated polyurethane and complies with DIN EN 1253-2 standards. Available in nominal widths of DN 70, DN 100, DN 125, DN 150, and DN 200, it offers a direct connection to pipes with push-fit sockets for gravity drainage. It includes a large integrated connection sleeve (495 mm x 495 mm) suitable for roof waterproofing membranes and liquid applied systems, and a fixing ring to secure the connection sleeve and support the included gravel trap.


Features and benefits:

  • Not sensitive to the weather (UV/ IR radiation, rain/ snow, temperature, ozone, etc.).
  • Impact and shock resistant.
  • Durable.
  • Heated option for most models.
  • Features a large inlet pot resulting in a high discharge rate.
  • Maximum discharge volume.
  • Up to size DN 200.
  • Robust construction.
  • Homogeneous roofing membrane connection.
  • Suitable for bridging all insulation thicknesses from 60 to 520 mm.

General information

Color

Black

Beige

Material

Polyurethane (PUR)

Shape

Circle

Square

Length

Bespoke

Width

70 mm

100 mm

125 mm

150 mm

200 mm

Show more

Manufacturer guidance

Pipe DN.

Height

Bespoke

Warranty description

Six year

Uniclass

Pr_65_50_35_37 Gravity rainwater outletsPrimary

CAWS

R10/26 Proprietary rainwater outlets

R10/365 Proprietary rainwater outlets

Specification data - Gravity rainwater outlets

Roof construction

-

Form

Guidance for specification option:

Insert details.

Roof insulation thickness

Guidance for specification option:

Insert details. Outlet is suitable for bridging all insulation thicknesses from 60 to 520 mm.

Material

Body: Rigid polyurethane integral foam.

Grating

Domed.

Spigots

DN70, outer diameter 75 mm.

Guidance for specification option:

Pipe connection length: 65 mm.

DN100,outer diameter 110 mm.

Guidance for specification option:

Pipe connection length: 67 mm.

DN125,outer diameter 125 mm.

DN150,outer diameter 160 mm.

Guidance for specification option:

Pipe connection length: 77 mm.

DN200,outer diameter 200 mm.

Guidance for specification option:

Pipe connection length: 101 mm.

Manufacturer guidance

Opening/ core borehole: 250 mm.

Consult manufacturer's literature for full details.

Integral accessories

Bitumen sleeve 495 x 495 mm.

Orientation

Vertical.

Standard

For main and emergency drainage to DIN EN 12056-3 and DIN 1986-100 for large used and unused flat roofs.

Accessories

Guidance for specification option:

Consult manufacturer for options and insert requirements, or omit.

Reaction to fire

Euroclass E/ B2 normal flammability.

Sustainability data

Country of material origin

Germany

Country of product manufacture

Germany

Material

Polyurethane (PUR)

Embodied carbon

A1-A3 (production stage) as defined in BS EN 15804

13.4 kg CO₂ eq/unit

Third party certifications

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
Revit
-

1

IFC
-

1

Third party certifications

BRE Certificate

BRE Certificate

BRE Rainwater Outlet Thermal Performance Certification

ISO 9001 Quality Management

ISO 9001 Quality Management

ISO 9001:2015 Quality Management System

TUV - Safety and Quality Report

TUV - Safety and Quality Report

LGA Certification - EN 1253-2:2015

EPD

EPD

Sita Flat-Roof Outlets – EPD

Literature

DN70 SitaStandard Vertical Roof Outlet -  Technical Drawing

DN70 SitaStandard Vertical Roof Outlet - Technical Drawing

DN100 SitaStandard Angled Roof Outlet - Technical Drawing

DN100 SitaStandard Angled Roof Outlet - Technical Drawing

DN100 SitaStandard Vertical Roof Outlet - Technical Drawing

DN100 SitaStandard Vertical Roof Outlet - Technical Drawing

DN125 SitaStandard Angled Roof Outlet - Technical Drawing

DN125 SitaStandard Angled Roof Outlet - Technical Drawing

DN125 SitaStandard Vertical Roof Outlet - Technical Drawing

DN125 SitaStandard Vertical Roof Outlet - Technical Drawing

DN150 SitaStandard Vertical Roof Outlet - Technical Drawing

DN150 SitaStandard Vertical Roof Outlet - Technical Drawing

DN200 SitaStandard Vertical Roof Outlet - Technical Drawing

DN200 SitaStandard Vertical Roof Outlet - Technical Drawing

DN70/DN100 SitaStandard Stepped Roof Outlet - Technical Drawing

DN70/DN100 SitaStandard Stepped Roof Outlet - Technical Drawing

DN70 SitaStandard Angled Roof Outlet - Technical Drawing

DN70 SitaStandard Angled Roof Outlet - Technical Drawing

60-520mm SitaStandard Extension Unit - Technical Drawing

60-520mm SitaStandard Extension Unit - Technical Drawing

60-220mm SitaStandard Extension Unit - Technical Drawing

60-220mm SitaStandard Extension Unit - Technical Drawing

DN100 SitaStandard Fluid Angled Roof Outlet - Technical Drawing

DN100 SitaStandard Fluid Angled Roof Outlet - Technical Drawing

DN100 SitaStandard Fluid Vertical Roof Outlet - Technical Drawing

DN100 SitaStandard Fluid Vertical Roof Outlet - Technical Drawing

DN125 SitaStandard Fluid Vertical Roof Outlet - Technical Drawing

DN125 SitaStandard Fluid Vertical Roof Outlet - Technical Drawing

DN125 SitaStandard Fluid Angled Roof Outlet - Technical Drawing

DN125 SitaStandard Fluid Angled Roof Outlet - Technical Drawing

DN150 SitaStandard Fluid Vertical Roof Outlet - Technical Drawing

DN150 SitaStandard Fluid Vertical Roof Outlet - Technical Drawing

DN200 SitaStandard Fluid Vertical Roof Outlet - Technical Drawing

DN200 SitaStandard Fluid Vertical Roof Outlet - Technical Drawing

DN70/DN100 SitaStandard Liquid Stepped Roof Outlet - Technical Drawing

DN70/DN100 SitaStandard Liquid Stepped Roof Outlet - Technical Drawing

DN70 SitaStandard Fluid Angled Roof Outlet - Technical Drawing

DN70 SitaStandard Fluid Angled Roof Outlet - Technical Drawing

DN70 SitaStandard Fluid Vertical Roof Outlet - Technical Drawing

DN70 SitaStandard Fluid Vertical Roof Outlet - Technical Drawing

60-160mm SitaStandard Extension Unit - Technical Drawing

60-160mm SitaStandard Extension Unit - Technical Drawing