NBS Source
I'm a manufacturer
Compare variants

Skyline Self-Supporting Skylight

Verified by manufacturer 4 months ago

Skyline Self-Supporting Skylight - Gable Ended

The Standard Patent Glazing Company Limited Variant:

Self-supporting skylight with slim, external extruded aluminium capping.

Jump to:
+44 (0)1924 461213 Website

Application

Roof glazing applications, to be used in conjunction with Skyline patent glazing.

Description

Self-supporting skylight with slim, external extruded aluminium capping.


Features and benefits:

  • Available with a choice of two cosmetic outer snap-on cappings which conceal all fixing screws, and an external snap-on capping to allow for design flexibility.
  • Can be combined with opening vents to offer a complete glazing solution.
  • Can span 1–30 panes in length and 1–10 panes in width - consult manufacturer for details.
  • Incorporates an extruded aluminium structural ridge, hip and sill members and 16 gauge aluminium insulated flashings to ridge or apex, hip/ verge and sill positions.
  • Manufactured in accordance with BS 5516: 2004 Code of Practice for the design and installation of vertical and sloping patent glazing.

General information

Color

Other

Guidance for specification option:

Available in non-metallic RAL colour requirement from the standard range.

Finish

Powder-coated

Guidance for specification option:

To BS 6496.

Material

Glass

Aluminium

Guidance for specification option:

Grade 6063 temper T6 aluminium alloy, conforming to BS EN 755-2.

Shape

Pentagon

Hexagon

Octagon

Other

Guidance for specification option:

Other polygonal shapes:

  • Heptagon.
  • Nonagon.
  • Decagon.
  • Dodecagon.
  • Hexadecagon.
  • Icosikaitetragon.

Rectangle

Show more

Length

Bespoke

Width

Bespoke

Height

Bespoke

Warranty description

Five year

Uniclass

Pr_30_59_72_31 Framed rooflightsPrimary

CAWS

H10/10 Patent glazing

H10/115 Patent glazing

L10/45 Rooflights

L10/460 Rooflights

Product range

Skylights

Specification data - Framed rooflights

Form

Gable ended.

Guidance for specification option:

Without vertical glazed upstand.

Size

Guidance for specification option:

Consult manufacturer and insert requirements.

Frame

-

Material

Aluminium.

Finish

-

Coating

Powder coating to BS EN 13438.

Colour

Guidance for specification option:

Consult manufacturer and insert requirements.

  • Available in non-metallic RAL colour requirement from the standard range.

Film thickness (minimum)

40 µm.

Glazing or infill

-

Type

Guidance for specification option:

A variety of glazing infill is available, e.g. clear laminated, heat soaked toughened, etc.

Consult manufacturer's literature for information.

Construction

Guidance for specification option:

Consult manufacturer and insert requirements.

Integral kerb

Aluminium.

Guidance for specification option:

The raised upstand kerb should be 100 mm wide (minimum).

Operation

-

Type

Manual.

Powered, electric.

Pneumatic.

Control

Not applicable.

Electric control - chain actuator, 24 V.

Electric control - chain actuator, 230 V.

Electric control - linear actuator, 24 V.

Electric control - linear actuator, 230 V.

Manual control - screwjack gear.

Pneumatic control - gas springs.

Accessories

Guidance for specification option:

Consult manufacturer and insert requirements.

Supporting structure

Concrete.

Steel.

Timber.

Manufacturer guidance

The raised upstand kerb should be 100 mm wide (minimum).

Slope

Vertical glazed upstand height

Not required.

Guidance for specification option:

If specifying Gable Ended, Hipped or Polygonal.

500 mm.

600 mm.

700 mm.

800 mm.

Show more

Trim

Aluminium cap.

Hardware

Manufacturer's standard.

Type

SPG2.

Guidance for specification option:

Depth: 55 mm.

SPG3.

Guidance for specification option:

Depth: 75 mm.

SPG4.

Guidance for specification option:

Depth: 100 mm.

Manufacturer guidance

Glazing bar.

Consult manufacturer before specifying a particular glazing bar.

Capping

PC1, extruded aluminium cap.

Manufacturer guidance

Glazing bar.

Outer pane

Guidance for specification option:

Insert requirements e.g. clear laminated, heat soaked toughened, etc.

Consult manufacturer's literature for information.

When 28 mm thick double glazed units are used, a centre pane thermal transmittance (U-Value) of at least 1.15 W/m²K can be achieved.

Manufacturer guidance

Glazing infill.

Cavity

16 mm Argon gas filled cavity with warm edge spacer bars.

Manufacturer guidance

Glazing infill.

Inner pane

Guidance for specification option:

Insert requirements e.g. clear laminated, heat soaked toughened, etc.

Consult manufacturer's literature for information.

When 28 mm thick double glazed units are used, a centre pane thermal transmittance (U-Value) of at least 1.15 W/m²K can be achieved.

Manufacturer guidance

Glazing infill.

Type

Not required.

Bottom hung, thermally broken.

Side hung, thermally broken.

Top hung, thermally broken.

Manufacturer guidance

Opening vents.

Quantity

Guidance for specification option:

1–20, insert requirements. If opening vents are not required, insert N/A.

Manufacturer guidance

Opening vents.

Controls

Not applicable.

Crank handle.

Guidance for specification option:

For use with screwjack gear.

Standard open/ close wall mounted switch.

Guidance for specification option:

For electric actuators.

Wall mounted thermostatic control panel with rain sensor.

Guidance for specification option:

For electric actuators.

Manufacturer guidance

Opening vents.

Sustainability data

Contains Red List materials

No

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

Recyclability

Recyclable

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

100 %

Literature

Opening Vents Brochure

Opening Vents Brochure

Similar products from The Standard Patent Glazing Company Limited

Heritage Self-Supporting Skylight

Heritage Self-Supporting Skylight

SkylineBox Self-Supporting Skylight

SkylineBox Self-Supporting Skylight