Verified by manufacturer 4 months ago
Skyway AOV Hinged Flat Glass Smoke Vent Rooflight, Hermetically Sealed Double Glazed - IGU
BRE Certificate
Certificate type
ISO 9001 Quality Management
Certificate type
DoP
Certificate type
A flatglass automatic opening vent (AOV) NSHEV rooflight.
For applications in commercial and residential buildings. Designed to be installed on flat roofs with no more than a 5° pitch.
A Flatglass AOV (Automatic Opening Vent) NSHEV (Natural Smoke and Heat Exhaust Ventilation) rooflight manufactured to BS EN 12101-2 for heat and smoke ventilation. The smoke vents come in two standard sizes, which achieve a Geometric Free Area (GFA) of 1.0 m² and 1.5 m² respectively.
Features and benefits:
Designed to standard loadings of 640 N/m² (snow) and 750 N/m² (wind) and in accordance with the following Standards:
Color | Black Grey Other |
Finish | Powder-coated |
Material | Aluminium Glass |
Shape | Rectangle |
Length | Bespoke Guidance for specification option: The external kerb sizes can be increased by adding a larger flashing detail, but do not reduce internal dims. 950 mm 1484 mm Manufacturer guidanceThese sizes are the minimum internal opening sizes. External kerb sizes can vary but internals have a minimum size limit due to testing and certification restrictions. |
Width | Bespoke Guidance for specification option: The external kerb sizes can be increased by adding a larger flashing detail, but do not reduce internal dims. 1054 mm Manufacturer guidanceThese sizes are the minimum internal opening sizes. External kerb sizes can vary but internals have a minimum size limit due to testing and certification restrictions. |
Height | Bespoke Manufacturer guidanceUnit is approx. 385mm tall. Bespoke heights achievable by changing kerb heights. |
Warranty description | 15 year |
Uniclass | |
CAWS | L10/45 Rooflights L10/460 Rooflights |
Product range |
Form | Flat. |
Size | 1.0 m² geometric free area (1344 x 1284 mm; 387 mm high).1.5 m² geometric free area (1884 x 1284 mm; 387 mm high).Manufacturer guidanceOverall kerb length x width; overall height. |
Product performance | |
Fire performance | |
Reaction to fire | Euroclass A1 non-combustible. |
Whole window U-value | 0.9 W/m²K.Guidance for specification option: Lowest U-value achievable; consult manufacturer for project-specific values. |
Frame | |
Material | Extruded aluminium. |
Finish | |
Coating | Powder coating to BS EN 12206-1. |
Colour | Anthracite Grey (RAL 7016).Black (RAL 9005).White (RAL 9010).Bespoke RAL.Guidance for specification option: Insert requirements. |
Film thickness (minimum) | Manufacturer's standard. |
Glazing or infill | |
Type | Insulating glass units, standard.Guidance for specification option: Double glazed. Insulating glass units, solar control.Insulating glass units, privacy glass.Insulating glass units, body tinted.Insulating glass units, acoustic laminate.Insulating glass units, coloured glass.Insulating glass units, CUin advanced thermal performance.Insulating glass units, low iron glass. |
Colour | Clear.Other.Guidance for specification option: Insert requirements. Hundreds of options are possible through the use of Vanceva® coloured laminated interlayer(s); consult manufacturer for details. |
Coating | Standard.Guidance for specification option: Double glazed. Easy-clean coating (Ritec). |
Operation | |
Type | Powered, electric, 24 V. |
Control | Battery back-up control panel.Guidance for specification option: Standard. Smoke, gas, wind and rain sensors.Guidance for specification option: Optional. Break glass and override switches.Guidance for specification option: Optional. Full integration to building fire management system.Guidance for specification option: Optional. |
Accessories | None.Standard blind under glass connected to base frame.Standard blind under glass in lightwell.Paint or sandblast borders.Manifestation.Guidance for specification option: Artwork, company logo or other - insert requirements. Emergency break glass unit.External kerb 1 m² (1284 x 1344 mm).External kerb 1.5 m² (1284 x 1884 mm).Fireman’s override switch.Integrate to BMS.Modular timber kerb at 5° pitch.Smoke detector.Specialist AOV control unit, 230 V to 24 V transformer plus battery backup. |
Snow load | 640 N/m². |
Wind load | 750 N/m². |
Outer pane | Heat soaked toughened glass. |
Cavity space fill | 16 mm argon filled with Swisspacer warm edge spacer, silicone bonded. |
Inner pane | Laminated glass. Heat soak tested toughened glass. |
Contains Red List materials | No |
Country of material origin | France |
Country of product manufacture | United Kingdom |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 0 kg CO₂ eq/kg Self declared |
Recyclability | Aluminium and glass are highly recycled |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 95 % |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 1 | |
- | 1 |
Data Sheet AOV Smoke Vent
Certificate EN 12101 Test
Data Sheet Flatglass Access Rooflights
Flatglass Brochure
Certificate ISO 9001 2023
Warranty Document
Certificate Weathertightness Test report
Data Sheet Smokelite AOV
DWG AOV 1.5m² Gfa long section view
DWG AOV 1.5m² Gfa plan view
DWG AOV 1.5m² Gfa span view
DWG AOV 1m² Gfa long section
DWG AOV 1m² Gfa Plan View
DWG AOV 1m² Gfa Span View