NBS Source
I'm a manufacturer
Compare variants

Skyway Manual Access Flat Glass Rooflight

Verified by manufacturer 5 months ago

Hermetically Sealed Double Glazed - IGU

Roofglaze Rooflights Ltd Variant:
Third party certifications:
  • ISO 9001 Quality Management

    Certificate type

  • BRE Certificate

    BRE Certificate

    Certificate type

A flatglass rooflight for occasional access to the roof with manual operation.

Jump to:
BOS
+44 (0)1480 474 797 Website

Application

Designed to be installed on all roof pitches and roof types. For applications in commercial, education, leisure and residential buildings.

Description

A flatglass rooflight with manual access, providing daylight, natural ventilation and occasional roof access. The frames are manufactured from extruded aluminium section to BS 1474, EN 12020-1:2001. Polyamide thermal breaks in lid and base frame to BS EN ISO 16396-2:2017 making the frames fully thermally broken and extremely thermally-efficient.


Features and benefits:

  • Manual operation with gas ram assist.
  • Locking handle.
  • Fully thermally broken aluminium frames prevent cold bridging, reducing the risk of condensation.
  • Fully insulated base frame provides excellent thermal efficiency.
  • Quick and easy to install. Cover cap for concealed fixings.
  • Marine grade powder coat as standard
  • Compatible with both flat and pitched roofs, Flatglass rooflights are installed to a builder’s kerb finished by roofing membrane.
  • Recommended minimum kerb pitch of 5° to help shed water.
  • Minimal framework: daylight is maximized while the visible framework is minimized.
  • More daylight -> less artificial light -> energy savings.
  • Free air calculations.


Designed to standard loadings of 640 N/m² (snow) and 750 N/m² (wind) and in accordance with the following Standards:

  • BS 6375-1 2015+A1 2016: Weather tightness.
  • BS EN 1026: Air permeability.
  • BS EN 1027: Water tightness test.
  • BS EN 12211: Wind resistance test.
  • BS 1474: Aluminium Extrusions.
  • EN 12020-1:2001: Aluminium Extrusions.
  • BS EN ISO 16396-2:2017: Polyamide Thermal Break.
  • BS EN 12206-1:2004: Powder Coating.

General information

Color

Black

Grey

Other

Finish

Powder-coated

Material

Aluminium

Glass

Shape

Rectangle

Square

Length

Bespoke

Guidance for specification option:

Size parameters apply. Minimum and maximum sizes apply. Contact RGR Sales for guidance.

Manufacturer guidance

Size parameters apply. Minimum and maximum sizes apply. Contact RGR Sales for guidance.

Width

Bespoke

Height

Bespoke

Warranty description

15 year

Uniclass

Pr_30_59_72_31 Framed rooflightsPrimary

CAWS

L10/45 Rooflights

L10/460 Rooflights

Product range

Skyway

Specification data - Framed rooflights

Form

Flat.

Size

-

Manufacturer guidance

Insert requirements; rectangular as standard - consult manufacturer for options.

Product performance

-

Fire performance

-

Reaction to fire

Euro Class A1 non-combustible.

Whole window U-value

0.4 W/m²K.

Guidance for specification option:

Lowest U-value achievable; consult manufacturer for project-specific values.

Frame

-

Material

Extruded aluminium.

Finish

-

Coating

Powder coating to BS EN 12206-1.

Colour

Anthracite Grey (RAL 7016).

Guidance for specification option:

Standard.

Black (RAL 9005).

White (RAL 9010).

Bespoke RAL.

Guidance for specification option:

Insert requirements.

Glazing or infill

-

Type

Insulating glass units, standard.

Guidance for specification option:

Double glazed.

Insulating glass units, solar control.

Insulating glass units, privacy glass.

Insulating glass units, body tinted.

Insulating glass units, acoustic laminate.

Insulating glass units, coloured glass.

Insulating glass units, CUin advanced thermal performance.

Insulating glass units, low iron glass.

Colour

Clear.

Other.

Guidance for specification option:

Insert requirements.

Hundreds of options are possible through the use of Vanceva® coloured laminated interlayer(s); consult manufacturer for details.

Coating

Standard.

Easy-clean coating (Ritec).

Integral kerb

-

Manufacturer guidance

Insert requirements.

  • Minimum kerb height: 150 mm (at the eaves end).
  • Minimum kerb thickness: 100 mm (including finishes) so frame is hidden from inside giving clean glass sight lines.
  • Maximum size: Dependent on glass specification.
  • Minimum recommended kerb pitch: 5° to shed water.

Operation

-

Type

Manual.

Control

Chrome D handle.

Chrome locking handle.

Accessories

None.

Paint or sandblast borders.

Manifestation.

Guidance for specification option:

Artwork, company logo or other - insert requirements.

Outer pane

Heat soak tested toughened glass.

Cavity space fill

16 mm argon filled with Swisspacer warm edge spacer, silicone bonded.

Inner pane

Laminated glass.

Heat soak tested toughened glass.

Snow load

640 N/m².

Wind load

750 N/m².

Sustainability data

Contains Red List materials

No

Country of material origin

France

Country of product manufacture

United Kingdom

Material

Aluminium

Glass

Recyclability

Glass and aluminium are highly recycled.

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

96 %

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
Revit
-

1

IFC
-

1

Third party certifications

ISO 9001 Quality Management

ISO 9001 Quality Management

ISO 9001 Certificate 2023

BRE Certificate

BRE Certificate

P110587-1000 Issue: 1

Literature

Data Sheet Flatglass Access Rooflights

Data Sheet Flatglass Access Rooflights

Flatglass Brochure

Flatglass Brochure

Certificate Weathertightness Test report

Certificate Weathertightness Test report

Warranty Document

Warranty Document

Case studies

Private Residence, Totteridge

Private Residence, Totteridge

Cambridge Mosque

Cambridge Mosque

Similar products from Roofglaze Rooflights Ltd

Skyway 24v Electric Hinged Flat Glass For Ventilation  - Glass Rooflight

Skyway 24v Electric Hinged Flat Glass For Ventilation - Glass Rooflight

Skyway AOV Hinged Flat Glass Smoke Vent Rooflight

Skyway AOV Hinged Flat Glass Smoke Vent Rooflight

Skyway Electric Access Flat Glass Rooflight

Skyway Electric Access Flat Glass Rooflight

Skyway Fixed Flat Glass Rooflight - Multi Pane

Skyway Fixed Flat Glass Rooflight - Multi Pane

Skyway Fixed Flat Glass Rooflight - Single Pane

Skyway Fixed Flat Glass Rooflight - Single Pane

Skyway Fixed Flat Glass Rooflight With Wall Abutment(s) - Multi Pane

Skyway Fixed Flat Glass Rooflight With Wall Abutment(s) - Multi Pane

Skyway Fixed Flat Glass Rooflight With Wall Abutment(s) - Single Pane

Skyway Fixed Flat Glass Rooflight With Wall Abutment(s) - Single Pane

Skyway Fixed Protect+ Flat Glass Rooflight

Skyway Fixed Protect+ Flat Glass Rooflight

Skyway Fixed Walk On Flat Glass Rooflight - Multi-Pane

Skyway Fixed Walk On Flat Glass Rooflight - Multi-Pane

Skyway Fixed Walk On Flat Glass Rooflight - Single Pane

Skyway Fixed Walk On Flat Glass Rooflight - Single Pane