NBS Source
I'm a manufacturer
Compare variants

SOLEAL Next 75 Sustainable Aluminium Window - Aluminium Thermally Broken Window

Verified by manufacturer 2 months ago

Open Out Top Hung

Technal Variant:
Third party certifications:
  • EPD

    EPD

    Certificate type

  • Secured By Design

    Secured By Design

    Certificate type

  • ISO 45001 Health and Safety Management

    Certificate type

  • ISO 9001 Quality Management

    Certificate type

High performance aluminium window and door system with enhanced thermal insulation.

Jump to:
+44 (0)1684 853 500 Website

Application

Suitable for all applications, including: commercial, residential, education and hospitality.

Description

SOLEAL Next casement is available in visible and minimal design, open-in and open-out to adapt to all types of architectures. There are multiple applications, shapes and colours and provides high performance levels for weather tightness, thermal, acoustic and sustainability complying with most international standards.


Features and benefits:

  • Available in open-in and open-out.
  • Wide range of profiles.
  • Concealed hardware.
  • Numerous opening possibilities.
  • Single or dual colour; possibility for differing finishes internally (eg. RAL colour) and externally (eg. anodized).
  • Drained and ventilated glazing; EPDM & EPDM foam gaskets.
  • Multi-chambered polyamide thermal breaks, mechanically jointed.
  • Trickle ventilator adaptors.
  • Doc M compliant threshold
  • Exceptional levels of weather performance and thermal insulation.
  • Burglar resistance up to RC3 and PAS24.
  • Secure multipoint locking.
  • Motorized opening and locking sensors.
  • Under certification to obtain Cradle to Cradle® label.
  • Less CO2 footprint.

General information

Color

White

Black

Grey

Finish

Powder-coated

Anodized

Material

Aluminium

Polyamide

Glass

Length

Bespoke

Width

Bespoke

Height

Bespoke

Uniclass

Pr_30_59_98_02 Aluminium window unitsPrimary

CAWS

L10/25 Aluminium windows

L10/330 Aluminium windows

Product range

Aluminium Windows

Specification data - Aluminium window units

Manufacturer

Technal.

Standard

Non-fire and / or smoke-rated windows to BS EN 14351-1 and BS 4873.

Third-party certification

CE marked; Q-Mark; EPD Certification; Secured by Design.

Dimensions and configurations

-

Manufacturer guidance

Consult manufacturer for details and insert requirements.

Product performance

-

Weather performance

-

UK exposure category

2000 Pa.

Guidance for specification option:

Notwithstanding any information within this Specification, all framing and infills shall be capable of withstanding the design wind loadings calculated in accordance BS EN 1991-1-4, and imposed loads as defined in BS EN 1991-1-1, and the Specialist Contractor shall carry out calculations to demonstrate this.

Air permeability

To EN 14351-1+A1, Class 4. (600 pa).

Watertightness

To EN 14351-1+A1, Class E1800. (1800 pa).

Resistance to wind load

To EN 14351-1+A1, Class C5. (2000 pa).

Durability

-

Operation and strength characteristics

20 000 Cycles in accordance with BS EN 1191:2012; Class 1 in accordance with EN 12046-1; Class 4 in accordance with EN 12046-1.

Loadbearing capacity of safety devices

To BS EN 14351-1:2002.

Safety

-

Security level

To PAS 24.

To Secured by Design standard.

Environmental

-

Background ventilation

Trickle ventilation.

Guidance for specification option:

  • Each window unit to be fitted with colour-matched powder coated aluminium trickle ventilators, to meet Building Regulations (e.g. Approved Document F, 2021). Ventilator to be secure and adjustable, complete with insect screen. Ventilator to be fitted through dedicated frame above the head of the outer frame, of identical material and finish to framing.
  • Where the window is of insufficient width to accommodate the level of ventilation required by Building Regulations the Specialist Contractor shall bring this to the attention of the Contract Administrator.
  • Trickle ventilation shall also comply with Approved Document J and BS5440 Part 2: 2009 with respect to ventilation of gas burning appliances. This requirement shall take precedence over the requirements of Approved Document F1.

Acoustic performance rating

Rw up to 48 dB.

Guidance for specification option:

  • Up to a maximum Rw = 48 dB (with double glazing 50 mm: 88.2 Si / 20 / 66.2 Si).
  • Actual performance dependant of glazing infill performance - to be determined, refer to acoustic report. 

Thermal

-

Whole window U-value

Guidance for specification option:

  • 1.2 W/m²K with 1.0 W/m²K DGU.
  • 0.8 W/m²K with 0.5 W/m²K TGU.  
  • Proof of calculation of U values to EN 10077-2 to be provided by Specialist Contractor.

Frame

-

Profile

Guidance for specification option:

Insert requirements.

  • All frames and other sections to be extruded to EN 12020, EN 573-3, EN 515 and EN 775 -1 to 9 from aluminium alloy specification 6060 T66 comprising a minimum of 75% recycled end-of-life aluminium (post-consumer scrap) and a GWP (A1-A3) of no greater than 1.9 kg of CO2e/kg of aluminium.  Provide EcoPlatform third party published EPD conforming to ISO14025 and EN15804+A2 to confirm the above. 
  • All aluminium billets and extrusions to be sourced from cast house and extrusion plants certified by Aluminium Stewardship Initiative (ASI) for Performance Standard and Chain of Custody Standard  
  • Thermal break comprising glass reinforced polyamide extrusions PA66 GF25 mechanically jointed to form a single compound profile. 
  • The thermal break is to be applicable to all profiles, including vents, couplers and cills. 
  • Joints to be sealed with sealants as specified by the aluminium systems company fabrication manual. 
  • All fabrication to be strictly in accordance with the system company’s Design and Fabrication and current Technical Bulletins.
  • Window manufacturer to affix their CE or UKCA Marking label to all windows.

Finish as delivered

-

Coating

Polyester powder-coated in accordance with BS EN 12206-1: 2021.

Guidance for specification option:

Any special warranties or guarantees (such as marine or industrial/ chlorine) to be issued directly by the powder supplier and agreed prior to material order.

Anodized to BS 3987:1991.

Manufacturer guidance

All finishing to be undertaken by Hydro Building Systems prior to delivery to the manufacturer.

Colour

-

Manufacturer guidance

Standard Technal finish from standard Technal range.

Consult manufacturer for details and insert requirements.

Film thickness (minimum)

Minimum 60 microns for polyester powder coated profiles.
Minimum 25 microns for anodized profiles.

Ventilator

Required.

Guidance for specification option:

  • Each window unit to be fitted with powder coated aluminium trickle ventilators, to meet Building Regulations (e.g. Approved Document F, 2021).
  • Ventilator to be secure and adjustable, complete with insect screen.
  • Ventilator to be fitted through the head of the outer frame, with a sleeve between inner and outer units.

Glazing or infill

-

Standard

Relevant parts of BS EN 1279.

Guidance for specification option:

  • BS EN12600: 2002: Glass in building. Pendulum test. Impact test method and classification for flat glass.
  • BS EN 1279. Glass in Buildings. Insulating Glass Units.

Requirements

Infill thickness up to 69 mm.

Guidance for specification option:

  • Glazing to windows to be secured by means of glazing beads.
  • Glazing to be hermetically sealed double-glazed units, in accordance with Building Regulations. Composition of units to be confirmed, with laminated low-e clear glass inner pane (to BS EN 356: 2000 P1A where required for PAS24 compliance).
  • Where self-cleaning coating is applied to the external pane, use non-silicone lubricated gasket.  Specialist Contractor to supply confirmation from glass supplier of gasket compatibility.
  • All glazing in WCs and bathrooms shall have obscured glass to the inner pane.
  • All glass within 800 mm from FFL shall be toughened or laminated. (Below 1500 mm if within a door or 300 mm of a door). 
  • Manifestation design and location to be confirmed by the Contract Administrator.
  • Recommendations of the Glass and Glazing Federation should be adhered to.
  • Heat soak test all toughened glass used as outer pane above ground floor or in all overhead glazing in accordance with BS EN 14179.
  • Carry out thermal safety check to all glazing. 
  • Full height barrier glazing to comply with; BS6180: 2011 Barriers in and about buildings. Code of Practice in respect of relevant point, U.D.L and line loads. 
  • Solid infill and spandrel panels to be tested and classified to Class A2 s-1, d0 or A1 according to BS EN 13501-1:2007+A1:2009 for reaction to fire.  
  • Glazed-in louvres to be tested and classified to Class A2 s-1, d0 or A1 according to BS EN 13501-1:2007+A1:2009 for reaction to fire.  

Hardware

Guidance for specification option:

Insert requirements.

  • Stainless steel friction hinges with optional non-lockable integral restrictor device where required. 
  • Load bearing safety devices (e.g. restrictors) to have been tested for load bearing capability to 350 N in accordance with CE/ UKCA marking requirements.
  • Multi-point locking system with/ without micro-ventilation keeps.

Operation

-

Type

Top hung.

Fixing features

-

Manufacturer guidance

To suit site conditions and building construction type. Quantity, type and size of fixings to be determined by window fabricator/ installer.

Opening Configuration

Open out.

Glazing bead

Internal for sash and fixed light.

Guidance for specification option:

Square, stepped or security beads available. Insert requirements.

Handles

Technal SELECTION.

Guidance for specification option:

Consult manufacturer and insert requirements.

TEMPTATION key locking/ non locking handles.

Guidance for specification option:

Consult manufacturer and insert requirements.

Sustainability data

Contains Red List materials

No

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

Material

Aluminium

Polyamide

Glass

Embodied carbon

A1-A3 (production stage) as defined in BS EN 15804

1.9 kg CO₂ eq/kg

Recyclability

95

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

75 %

Third party certifications

BIM objects

Platform Compatible Version
Revit
-

1

Third party certifications

EPD

EPD

Soleal Next 75 Tilt & Turn EPD

EPD

EPD

Soleal Next 75 Top Hung EPD

Secured By Design

Secured By Design

Secured by Design - certficate

ISO 45001 Health and Safety Management

ISO 45001 Health and Safety Management

ISO45001

ISO 9001 Quality Management

ISO 9001 Quality Management

ISO9001

Literature

Technal Soleal Next window Datasheet

Technal Soleal Next window Datasheet

Technal Soleal Next 75 Window Brochure

Technal Soleal Next 75 Window Brochure