NBS Source
I'm a manufacturer
Compare variants

SPEEDLINE Independent Wall liner System Utilising Siniat Board

Verified by manufacturer 2 months ago

Speedline frame with 50 mm-wide I-Studs

Metsec (voestalpine Metsec) Variant:
Third party certifications:
  • BSI Kitemark

    BSI Kitemark

    Certificate type

  • EPD

    EPD

    Certificate type

  • ISO 9001 Quality Management

    Certificate type

  • UK Conformity Assessed (UKCA)

    UK Conformity Assessed (UKCA)

    Certificate type

Independent wall lining system based on SPEEDLINE framing and Siniat boards.

Jump to:
+44 (0) 121 601 6000 Website

Application

Suitable for use in the following sectors:

  • Residential.
  • Healthcare.
  • Education.
  • Commercial.
  • Retail.
  • Student accommodation.
  • Renovation Maintenance Improvement (RMI).

Description

Independent wall lining system based on SPEEDLINE framing and Siniat boards.


Features and benefits:

  • Designed to provide a lining solution that is totally free of the substrate.
  • Can be used where other lining solutions such as plaster or direct bond are unsuitable.
  • Provides a cavity for services to be routed through.
  • A range of I-Stud widths between 50 and 146 mm achieves a wide range of height requirements: up to 7.2 metres without any additional bracing to the structure (it can be braced back for greater heights).
  • Suitable for fixing all types of plasterboard including Speedline thermal laminate boards. Systems utilizing British Gypsum Gyproc board or Knauf board are available to specify separately.
  • Speedline stud can hold insulation to improve levels of sound and thermal insulation.


Installation:

Speedline I-Studs are friction-fitted within Speedline tracks at nominal 600 mm centres. Board lining is fixed at maximum 300 mm centres to all perimeters and intermediate I-Studs using the appropriate length of Speedline drywall screw.

General information

Material

Steel

Plasterboard

Uniclass

Ss_25_25_45_35 Gypsum board wall lining systemsPrimary

CAWS

K10/155 Wall lining system (metal studs)

K10/30 Metal stud

Product range

Drylining / Linings - Independent Wall Lining

Specification data - Gypsum board wall lining systems

Damp-proof course

-

Manufacturer guidance

Insert requirements or omit.

The manufacturer recommends ensuring the substrate is sound and free of any damp prior to installing the Speedline independent wall lining system.

Support

50 mm I-Stud (PI50) with standard track (SPT52).

50 mm I-Stud (PI50) with Deep track (50 mm leg, SPEDT52).

Manufacturer guidance

I-Stud: 38 mm flange; available in 2700, 3000 and 3600 mm lengths.

Track supplied in 3000 mm lengths as standard.


Speedline I-Studs can be spliced together to create longer lengths using a 600-mm length of the appropriate sized Speedline deep track and fixed with four Speedline wafer head screws to each flange.

Insulation

Not required.

25 mm-thick glass mineral wool.

50 mm-thick glass mineral wool.

Manufacturer guidance

Insert requirements or omit.

Be aware that Speedline I-Stud is designed to hold insulation but also includes slots for routing of services.

Linings

-

Inner layers

Siniat GTEC 12.5 mm Standard Board.

Guidance for specification option:

Maximum height (studs at 600 mm centres):

  • With inner layer only: 2400 mm.
  • With inner and face layer: 2700 mm.

Siniat GTEC 15 mm Standard Board.

Guidance for specification option:

Maximum height (studs at 600 mm centres):

  • With inner layer only: 2400 mm.
  • With inner and face layer: 2700 mm.

Siniat GTEC 12.5 mm dB Board.

Guidance for specification option:

Maximum height (studs at 600 mm centres):

  • With inner layer only: 2400 mm.
  • With inner and face layer: 2700 mm.

Siniat GTEC 15 mm dB Board.

Guidance for specification option:

Maximum height (studs at 600 mm centres):

  • With inner layer only: 2400 mm.
  • With inner and face layer: 2700 mm.

Siniat GTEC 12.5 mm Fire Board.

Guidance for specification option:

Maximum height (studs at 600 mm centres):

  • With inner layer only: 2400 mm.
  • With inner and face layer: 2700 mm.

Siniat GTEC 15 mm Fire Board.

Guidance for specification option:

Maximum height (studs at 600 mm centres):

  • With inner layer only: 2400 mm.
  • With inner and face layer: 2700 mm.

Siniat 15 mm Megadeco Board.

Guidance for specification option:

Maximum height (studs at 600 mm centres): 2400 mm.

Manufacturer guidance

Maximum heights calculated based on a limiting deflection of L/240 at 200 Pa.

Consult manufacturer for details of 400 mm centre configurations.

Face layer

To match inner layer.

Guidance for specification option:

For severe duty rating.


Not available for Siniat 15 mm Megadeco Board.

Not required/ not applicable.

Guidance for specification option:

Standard for Siniat 15 mm Megadeco Board.

Fasteners

Speedline drywall screws.

Guidance for specification option:

Consult manufacturer's fixing and finishing solutions literature for options and insert requirements.

Joint treatment

Speedline Drywall Fibreglass Tape.

Speedline Ready Mix Joint Compound.

Speedline Corner Bead Tape.

Finish

-

Manufacturer guidance

Insert requirements or omit.

System accessories

Speedline Fire Rated Acoustic Sealant.

Speedline PB24 Partition Brace.

Speedline FS24 Flat Bracing Strip.

Speedline Service Support Plate.

Speedline Putty Pads.

Integral accessories

Speedline C-Studs.

Guidance for specification option:

For wall abutments, internal and external corners; size to correspond to I-Stud specified.

Size (w x h)

-

Manufacturer guidance

Insert requirements for nominal width and height.

 

Maximum height dependent on stud and panel type/ configuration - see Inner layer guidance for details.

Sustainability data

Third party certifications

Third party certifications

BSI Kitemark

BSI Kitemark

BIM Level 2 Kitemark - For Design and Construction Phase

BSI Kitemark

BSI Kitemark

BSI Kitemarkâ„¢ for BIM Objects

EPD

EPD

Environmental Product Declaration EPD - Drylining

ISO 9001 Quality Management

ISO 9001 Quality Management

ISO 9001:2015 Quality Management System

UK Conformity Assessed (UKCA)

UK Conformity Assessed (UKCA)

UKCA Declarations of Performance - Drylining

Literature

SPEEDLINE Wall Lining Systems

SPEEDLINE Wall Lining Systems

SPEEDLINE Fixings and Finishing Solutions

SPEEDLINE Fixings and Finishing Solutions

Product Data Sheet - Drylining

Product Data Sheet - Drylining

Similar products from Metsec (voestalpine Metsec)

SPEEDLINE Independent Wall liner System Utilising British Gypsum Gyproc Board

SPEEDLINE Independent Wall liner System Utilising British Gypsum Gyproc Board

SPEEDLINE Independent Wall liner System Utilising Knauf Board

SPEEDLINE Independent Wall liner System Utilising Knauf Board

SPEEDLINE Wall liner System Utilising British Gypsum Gyproc Board

SPEEDLINE Wall liner System Utilising British Gypsum Gyproc Board

SPEEDLINE Wall liner System Utilising Knauf Board

SPEEDLINE Wall liner System Utilising Knauf Board

SPEEDLINE Wall liner System Utilising Siniat Board

SPEEDLINE Wall liner System Utilising Siniat Board

TRADELINE Independent Wall liner System Utilising British Gypsum Gyproc Board

TRADELINE Independent Wall liner System Utilising British Gypsum Gyproc Board