Verified by manufacturer 2 months ago
BES 6001
Certificate type
BSI Kitemark
Certificate type
EPD
Certificate type
ISO 14001 Environmental Management Systems
Certificate type
ISO 9001 Quality Management
Certificate type
UK Conformity Assessed (UKCA)
Certificate type
Metal furring (MF) suspended ceiling system based on SPEEDLINE furring and Knauf boards.
Suitable for internal use in commercial and domestic
applications, where services are to be incorporated, or when upgrading and protecting existing structures, in the following sectors:
Metal furring (MF) suspended ceiling system based on SPEEDLINE furring and Knauf boards.
Features and benefits:
Material | Steel Plasterboard |
Uniclass | |
CAWS | K10/50 Suspended ceiling system on metal framing K10/220 Proprietary suspended ceiling system K10/175 Wall lining system (metal furrings) K10/41 Wall lining system (metal furrings) |
Product range |
Suspension grid | Speedline metal furring system.Guidance for specification option: Speedline 50 mm SSMF5 ceiling furring:
Speedline SSMF6A perimeter channel:
Speedline SSMF7 primary channel:
Manufacturer guidanceAll components are 3600 mm long as standard. Channels can be overlapped (minimum 150 mm) as required. Consult manufacturer's literature for details. See System accessories for additional components. |
Suspension grid fasteners | Speedline drywall wafer head screws.Guidance for specification option: Two per angle/ channel join. |
Insulation | Manufacturer guidanceInsert requirements; insulation to suit specification. |
Linings | |
Inner layers | To match face layer.Not required. |
Face layer | Knauf board.Manufacturer guidanceConsult manufacturer's literature for imposed load figures. Speedline thermal laminate board is also available to provide thermal insulation in a single application; consult manufacturer for details. |
Fasteners | Speedline drywall screws.Guidance for specification option: Consult manufacturer's fixing and finishing solutions literature for options and centre distances, and insert requirements. |
Joint treatment | Speedline fire-rated acoustic sealant.Guidance for specification option: For use to seal any air gaps at junctions of linings with walls, floors, ceilings and around openings. apply a continuous bead of sealant to clean, dry, dust-free surfaces ,leaving no air gaps. |
Finish | Manufacturer guidanceInsert requirements or omit. |
System accessories | AMF9B pre-formed clips.Guidance for specification option: Note: In domestic and residential applications, SMF5 ceiling channel to be screw fixed to SMF7 primary channel using two Speedline self-drilling wafer head screws. SSL06 90° angles, 25 x 25 mm.Guidance for specification option: Stock length: 3000 or 3600 mm. AMF12B angle fixing brackets.AAH01B acoustic hangers, 35 mm.AAH02B acoustic hangers, 70 mm. |
Fire resistance | 60 minutes to BS 476; part 23:1987, BRE Test Reference 236868 2007. |
BES 6001
BES 6001 Responsible Sourcing of Construction Products
BSI Kitemark
BIM Level 2 Kitemark - For Design and Construction Phase
BSI Kitemark
BSI Kitemark™ for BIM Objects
EPD
Environmental Product Declaration EPD - Drylining
ISO 14001 Environmental Management Systems
ISO 14001:2015 Environmental Management System
ISO 9001 Quality Management
ISO 9001:2015 Quality Management System
UK Conformity Assessed (UKCA)
UKCA Declarations of Performance - Drylining