Verified by manufacturer 6 months ago
EN 1627-1630 RC2
Certificate type
TUV NORD
Certificate type
Certificate of Approval
Certificate type
UK Conformity Assessed (UKCA)
Certificate type
Declare
Certificate type
Energy-saving automatic sliding doo with RC2 certified burglary protection.
For use in escape routes and emergency exits.
With the ST PRO Green automatic sliding door, dormakaba underlines its contribution to increased energy efficiency and sustainability. The anti-intruder protection, which has been tested and certified by ift Rosenheim, also takes into account the increasing need for security. The slim profile system can be equipped with double and triple glazing, which makes it possible to achieve particularly low Uᴅ values.
Features and benefits:
Standardisation and testing:
Color | Clear |
Finish | Powder-coated Anodized |
Material | Glass Aluminium |
Shape | Rectangle |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | One year |
Uniclass | |
CAWS | L20/60 Doors L20/520 Sliding doors L20/490 Automatic doors |
Performance | External. |
Arrangement | One-leaf sliding door.Two-leaf sliding door.One-leaf sliding door with side screen.Two-leaf sliding door with side screens. |
Track system | Overfloor rail.Underfloor rail milled.Underfloor rail elevated. |
Door leaves | |
Construction | Security insulating glass, grade P4A, continuous floor guide.Guidance for specification option: Standard. Security insulating glass, grade P4A with side panels.Guidance for specification option: Optional. Security insulating glass, grade P4A with skylight.Guidance for specification option: Optional. Security insulating glass, grade P4A with safety screens.Guidance for specification option: Optional. |
Finish and colour | Anodized.Powder-coated, custom colour.Guidance for specification option: Consult manufacturer and insert requirements. |
Operation | Powered.Guidance for specification option: Energy-efficient sliding door drive ES PROLINE. |
Accessories | Not required.Fan light. |
Burglar resistance | RC2. |
Mounting | On wall. Within blockwork. |
Opening direction | Left. Right. Bi-parting. |
Glazing | ISO 33.52 mm P4A - SZR 18 - TSG 6 Ug 1.1 warm edge. ISO 33.52 mm P4A - SZR 20 - TSG 4 Ug 1.1 warm edge. ISO 49.52 mm P4A - SZR 14 - TSG 6 = SZR 14 - TSG 6 Ug 0.6 warm edge. ISO 49.52 mm P4A - SZR 14 - TSG 5 = SZR 15 - TSG 6 Ug 0.6 warm edge. ISO 34.28 mm P5A - SZR 18 - TSG 6 Ug 1.1 warm edge. |
Casing | Standard casing, 100 mm. Guidance for specification option:
Standard casing, 150 mm. Guidance for specification option:
Sensor casing, 100 mm. Guidance for specification option:
Sensor casing, 150 mm. Guidance for specification option:
Integrated casing with drop down cover. Guidance for specification option:
Manufacturer guidance
|
Mid rails | Not required. Moving panel(s). Side screen(s). Moving panel(s) and side screen(s). |
Locking device | Not required. Electro-mechanical locking (mono-stable). Electro-mechanical (bi-stable). Electromagnetic locking. Without manual release. Manufacturer guidanceConsult manufacturer's literature for details. |
Monitoring |
Door status message. Manufacturer guidanceDoor monitoring. |
Safety | Activation safety sensor (external) - IXIO Combisensor CAN. Activation safety sensor (external) - IXIO Sateysensor CAN. Activation safety sensor (external) - IXIO-DT3 for emergency exit. Activation safety sensor (external) - IXIO-DT1/D01. Activation safety sensor (external) - ISIO-ST/SO 270. Manufacturer guidanceSafety and security.
|
Activation | Not required. Night bank facility - Key switch KT3-1 FM. Night bank facility - Key switch TL-ST S55. Night bank facility - Key switch CAN. Door pilot interface with door pilot app connectivity. Manufacturer guidanceDoor activation options. |
Program switch | Not required. 5-Digit Mechanical program switch. 5-Digit Mechanical program switch lockable. 5-Digit Mechanical program switch lockable with half cylinder. 5-Digit Elecronical program switch lockable. Manufacturer guidance
|
Access control | Not required. dormakaba access control system. Access control by others. Guidance for specification option: Operator will require a normally open volt free contact momentarily closed on receipt of a valid signal from the access control system. Manufacturer guidanceIntegration with access control. |
Power failure | Monitored 1.2 Ah battery backup system to automatically open the doors in the case of a power failure or upon a signal from the interfaced fire alarm system. Monitored 2.3 Ah battery backup system to automatically open the doors in the case of a power failure or upon a signal from the interfaced fire alarm system. |
Voltage | 230 V, 50/60 Hz. Manufacturer guidanceSupply voltage. |
Power consumption | 130 W. |
Ingress protection (IP) rating | IP 20. |
Operating temperature range | -20°C to + 60°C. |
Acceptable relative air humidity | 93% (maximum). |
Dimensions | Manufacturer guidanceConsult manufacturer's literature for door parameters and insert requirements. |
Standard | To EN 16005. |
Contains Red List materials | No |
Country of material origin | Europe |
Country of product manufacture | Germany |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 844 kg CO₂ eq/unit Self declared |
Recyclability | 94% |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 15.2 % |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 1 | |
- | 1 |
EN 1627-1630 RC2
ST PRO Green RC2 - EN 1627-1630:2011
TUV NORD
ST PRO Green RC2 - EN 16005
Certificate of Approval
ST PRO Green RC2 - EN 16361:2016-12
UK Conformity Assessed (UKCA)
St PRO Green RC2 - UKCA Declaration of Conformity
Declare
ST PRO Green RC2 - EC Declaration of Conformity
Declare
ST PRO Green RC2 - Environmental Product Declaration