NBS Source
I'm a manufacturer
Compare variants

Stannah Xtralift passenger lift

Verified by manufacturer 2 months ago

Passenger lift

Stannah Lifts Variant:
Third party certifications:
  • Health & Safety Accreditation

    Health & Safety Accreditation

    Certificate type

  • CHAS

    CHAS

    Certificate type

  • ISO 45001 Health and Safety Management

    Certificate type

  • ISO 9001 Quality Management

    Certificate type

Core passenger lift range: customizable, high-performance lifts with a broad range of options and finishes.

Jump to:
+44 (0)1264 343777 Website

Application

Suitable for most low and medium-rise passenger lift applications, including airports, hospitals, luxury residences, including heavy duty, fire-fighting, evacuation and bespoke finish requirements.

Description

Core passenger lift range: customizable, high-performance lifts with a broad range of options and finishes.

An efficient, high performance gearless traction drive ensures a smooth ride with low noise, energy use and running costs.

Designed with space-saving in mind, with compact controls at the top of the shaft. A fast, efficient installation is ensured by the exclusive rail system, providing durability and reliability.


Features and benefits:

  • Caters for 6–33 persons (450–2500 kg).
  • Speed: up to 2.5 m/s.
  • Increased travel, up to 45 m in height (potentially up to 16 floors).
  • Automatic relevelling to landing floor.
  • Anti-creep device to prevent movement away from landing.
  • Overload weighing device.
  • Emergency lighting within lift car giving three hour duration.
  • Advanced door opening.
  • Communication: EN 81-28 compliant autodialler.
  • Eco-efficiency features: Includes LED lights and drive stand-by modes.
  • Curtain of light (COL) safety features prevent door closure when an object is detected in the path of doors.
  • Complies with BS EN 81-20, EN 81-50, and EN 81-70 (disabled access compliance) and EN 81-73 (behaviour of lifts in the event of fire).
  • Additional lift configuration options are available for conformance to EN 81-71 (vandal resistant lifts), EN 81-72 (fire fighters lifts), and BS EN 81-76/ BS 9999 (evacuation lifts).
  • CE marked and manufactured in accordance with The Lift Directive 95/16/EC.


The shaft size is determined by various factors, including capacity, door type and opening width plus entrance position. Consult manufacturer for details.

General information

Color

-

Manufacturer guidance

Bespoke, contact manufacturer for details.

Finish

Other

Material

Steel

Shape

Square

Rectangle

Guidance for specification option:

Includes stretcher lifts.

Length

1300 mm

1400 mm

1600 mm

1750 mm

2100 mm

Show more

Width

1000 mm

1100 mm

1200 mm

1400 mm

1800 mm

Show more

Warranty description

One year

Guidance for specification option:

As standard.

Uniclass

Ss_80_50_60_26 Electric passenger and goods-passenger lift systemsPrimary

CAWS

X12/110 Vertical lifting platform systems

X12/350 Platform lifts

X12/110 Vertical lifting platform systems

Product range

Passenger lifts

Specification data - Electric passenger and goods-passenger lift systems

Lift type

Passenger lift.

Manufacturer guidance

All lift types comply with the following standards:

  • EN 81-20: construction and installation safety.
  • EN 81-50: component examination and tests.
  • EN 81-70: lift accessibility.
  • EN 81-28: remote alarm systems.
  • EN 81-73: lift behaviour in the event of a fire.
  • EN 81-58: lift door fire resistance.

Drive space

Machine room-less (MRL).

Lift components

See below.

Electrical supplies to firefighters' and evacuation lifts

-

Primary source

-

Secondary source

-

Door arrangement

Single entrance.

Through entrances.

Guidance for specification option:

Opposite front and rear.

Adjacent entrances: front and left side.

Guidance for specification option:

Consult manufacturer for lift size availability.

Adjacent entrances: front and right side.

Guidance for specification option:

Consult manufacturer for lift size availability.

Traction drive

Gearless.

Drive position

MRL.

Speed control

1.0–2.5 m/s.

Control of lift drive

Down collective, simplex.

Down collective, duplex.

Down collective, triplex.

Full collective, simplex.

Full collective, duplex.

Full collective, triplex.

Roping

-

Type

-

Manufacturer guidance

Consult manufacturer for details and insert requirements.

Arrangement

-

Manufacturer guidance

Consult manufacturer for details and insert requirements.

Compensation

-

Manufacturer guidance

Consult manufacturer for details and insert requirements.

Lift shaft and machine room cabling and containment

-

Cable type

-

Manufacturer guidance

Consult manufacturer for details and insert requirements.

Containment

-

Manufacturer guidance

Consult manufacturer for details and insert requirements.

Containment accessories

-

Manufacturer guidance

Consult manufacturer for details and insert requirements.

Rewireable installation

-

Manufacturer guidance

Consult manufacturer for details and insert requirements.

Concealed installation

-

Manufacturer guidance

Consult manufacturer for details and insert requirements.

Type

Xtralift Passenger Lift

Guidance for specification option:

Fabricated steel lift car frame including header assembly, platform buffer plates and guide shoes with lubricators.

Shaft type

Wall mounted.

Guidance for specification option:

Standard. Requires a lifting beam at top and scaffolding.

Lower lift costs, higher building costs due to construction of load-bearing wall, smaller shaft size.

FX structure supported.

Guidance for specification option:

Can be installed almost anywhere.

Offers reduced construction cost, higher lift cost and a slightly larger shaft size (optional for 6, 8 and 13 stretcher person lifts, not suitable for 13 person square).

Manufacturer guidance

Headroom: 3400–4000 mm.

Pit depth: 1100–1500 mm.

Car size / Capacity (w x d)

6 person (450 kg)/ 1000 x 1300 mm.

8 person (630 kg)/ 1100 x 1400 mm.

13 person stretcher (1000 kg)/ 1400 x 2100 mm.

13 person square (1000 kg)/ 1400 x 1600 mm.

17 person (1250 kg)/ 1950 x 1400 mm.

Show more

Manufacturer guidance

Car height: 2100 mm.

Doors

Telescopic, open left (stainless steel finish).

Guidance for specification option:

Two panels.

Telescopic, open left (primed).

Guidance for specification option:

RAL 7044 silk grey.

Two panels.

Telescopic, open right (stainless steel finish).

Guidance for specification option:

Two panels.

Telescopic, open right (primed).

Guidance for specification option:

RAL 7044 silk grey.

Two panels.

Centre opening, two panels (stainless steel finish).

Show more

Manufacturer guidance

Frame and sills to match.

Clear opening

Guidance for specification option:

Not all widths are available for all capacities and openings; consult technical literature for exact details and insert requirements.

Ceiling

Mirror stainless steel.

Guidance for specification option:

Standard.

Manufacturer guidance

A variety of cabin finishes are available for the walls, floors and ceilings please refer to Stannah literature for details.

Special and custom finishes are also available - consult manufacturer.

Lighting

H80 lighting: L40.

Guidance for specification option:

Standard.

H80 lighting: L24.

H80 lighting: L21.

H80 lighting: L90 (fixed size 600 x 600 mm).

H80 lighting: L95 (fixed size 600 x 600 mm).

Show more

Manufacturer guidance

Consult manufacturer's literature for illustrations.

Walls

Vinyl skin plate, K01 White.

Guidance for specification option:

Standard.

Vinyl skin plate, K04 Night Black.

Guidance for specification option:

Standard.

Vinyl skin plate, K10 Atlantic Blue.

Guidance for specification option:

Standard.

Vinyl skin plate, K11 Techno Grey.

Guidance for specification option:

Standard.

Vinyl skin plate, K17 Nature Beige.

Guidance for specification option:

Standard.

Show more

Manufacturer guidance

A variety of cabin finishes are available for the walls, floors and ceilings please refer to Stannah literature for details.

Special and custom finishes are also available - consult manufacturer.

Flooring

Vinyl, R59 Vinyl Stone Grey Concrete.

Vinyl, R61 Vinyl Stone Black Concrete.

Vinyl rubber, R74 Classic timber.

Vinyl rubber R75 Greywashed timber.

Antibacterial vinyl R16 Antibacterial dolphin.

Show more

Manufacturer guidance

A variety of cabin finishes are available for the walls, floors and ceilings please refer to Stannah literature for details.

Special and custom finishes are also available - consult manufacturer.

Handrail

End-mounted: P13X12 Mirror stainless steel with rounded ends.

Guidance for specification option:

Standard; EN 81-70 compliant.

End-mounted P13E04 Black stainless steel with rounded ends.

Guidance for specification option:

EN 81-70 compliant.

Buttress-mounted P12X12 Mirror stainless steel with rounded ends.

Buttress-mounted P12E04 Black stainless steel with rounded ends.

Not required.

Panel configuration

Half height, Supra X02.

Half height, Supra X12.

Half height, Supra X13.

Half height, Supra X24.

Half height, Supra X25.

Show more

Control panel finish

Stainless steel, X02 SB Finish Steel.

Guidance for specification option:

Standard; Scotch-Brite™.

Stainless steel, X12 Mirror Finish Steel.

Stainless steel, X13 Linen.

Stainless steel, X25 Golden Shine.

Colour, AC2 Red.

Show more

Manufacturer guidance

Stainless steel AISI 304, except X02.

Frame material: Aluminium coloured black (AL04).

Landing display

LCD-070E 7” display.

Guidance for specification option:

Standard.

TFT-070E 7” display.

LCD-043 4.3” display.

639 2.3” display.

VS=LCD 2.3” display.

Mirror

Half height mirror (full width).

Guidance for specification option:

Fitted as standard.

Narrow mirror.

Full height narrow mirror.

Guidance for specification option:

Not EN 81-70 compliant.

Full mirror with band.

Full mirror.

Guidance for specification option:

Not EN 81-70 compliant.

Sustainability data

Contains Red List materials

No

Country of material origin

Spain

Country of product manufacture

Spain

Recyclability

95

Third party certifications

Health & Safety Accreditation

Health & Safety Accreditation

Certificate of Health & Safety Accreditation

CHAS

CHAS

CHAS – Contractors Health and Safety Assessment Scheme SSIP

ISO 45001 Health and Safety Management

ISO 45001 Health and Safety Management

ISO 45001 Health and Safety Management

ISO 9001 Quality Management

ISO 9001 Quality Management

ISO 9001 Quality Management

Literature

Stannah Xtralift passenger lift brochure - core range

Stannah Xtralift passenger lift brochure - core range

Stannah Passenger lift user handbook

Stannah Passenger lift user handbook

Case studies

Peabody Nods for Stannah Passenger Lifts in St John’s Hill Social Housing Regeneration

Peabody Nods for Stannah Passenger Lifts in St John’s Hill Social Housing Regeneration

Emergency Evacuation Passenger Lift Rebuilds Access in Restoration of the Chapel, Royal Victoria Country Park

Emergency Evacuation Passenger Lift Rebuilds Access in Restoration of the Chapel, Royal Victoria Country Park

“Oyez! Stannah brings modern access to historic town hall!”

“Oyez! Stannah brings modern access to historic town hall!”

Stannah Lifts Access In Award-winning Affordable Housing Scheme

Stannah Lifts Access In Award-winning Affordable Housing Scheme

Stannah Passenger Lift for Hospice Extension

Stannah Passenger Lift for Hospice Extension

Stannah Passenger Lifts Up Access in Multi Award-winning Listed Conversion

Stannah Passenger Lifts Up Access in Multi Award-winning Listed Conversion

The ‘best small building in London’ gets two Stannah Xtralifts

The ‘best small building in London’ gets two Stannah Xtralifts

Similar products from Stannah Lifts

Stannah Maxilift passenger lift

Stannah Maxilift passenger lift