Core passenger lift range: customizable, high-performance lifts with a broad range of options and finishes.
Suitable for most low and medium-rise passenger lift applications, including airports, hospitals, luxury residences, including heavy duty, fire-fighting, evacuation and bespoke finish requirements.
Core passenger lift range: customizable, high-performance lifts with a broad range of options and finishes.
An efficient, high performance gearless traction drive ensures a smooth ride with low noise, energy use and running costs.
Designed with space-saving in mind, with compact controls at the top of the shaft. A fast, efficient installation is ensured by the exclusive rail system, providing durability and reliability.
Features and benefits:
The shaft size is determined by various factors, including capacity, door type and opening width plus entrance position. Consult manufacturer for details.
Color | Manufacturer guidanceBespoke, contact manufacturer for details. |
Finish | Other |
Material | Steel |
Shape | Square Rectangle Guidance for specification option: Includes stretcher lifts. |
Length | 1300 mm 1400 mm 1600 mm 1750 mm 2100 mm |
Width | 1000 mm 1100 mm 1200 mm 1400 mm 1800 mm |
Warranty description | One year Guidance for specification option: As standard. |
Uniclass | |
CAWS | X12/110 Vertical lifting platform systems X12/350 Platform lifts X12/110 Vertical lifting platform systems |
Product range |
Lift type | Passenger lift.Manufacturer guidanceAll lift types comply with the following standards:
|
Drive space | Machine room-less (MRL). |
Lift components | See below. |
Electrical supplies to firefighters' and evacuation lifts | |
Primary source | |
Secondary source | |
Door arrangement | Single entrance.Through entrances.Guidance for specification option: Opposite front and rear. Adjacent entrances: front and left side.Guidance for specification option: Consult manufacturer for lift size availability. Adjacent entrances: front and right side.Guidance for specification option: Consult manufacturer for lift size availability. |
Traction drive | Gearless. |
Drive position | MRL. |
Speed control | 1.0–2.5 m/s. |
Control of lift drive | Down collective, simplex.Down collective, duplex.Down collective, triplex.Full collective, simplex.Full collective, duplex.Full collective, triplex. |
Roping | |
Type | Manufacturer guidanceConsult manufacturer for details and insert requirements. |
Arrangement | Manufacturer guidanceConsult manufacturer for details and insert requirements. |
Compensation | Manufacturer guidanceConsult manufacturer for details and insert requirements. |
Lift shaft and machine room cabling and containment | |
Cable type | Manufacturer guidanceConsult manufacturer for details and insert requirements. |
Containment | Manufacturer guidanceConsult manufacturer for details and insert requirements. |
Containment accessories | Manufacturer guidanceConsult manufacturer for details and insert requirements. |
Rewireable installation | Manufacturer guidanceConsult manufacturer for details and insert requirements. |
Concealed installation | Manufacturer guidanceConsult manufacturer for details and insert requirements. |
Type | Xtralift Passenger Lift Guidance for specification option: Fabricated steel lift car frame including header assembly, platform buffer plates and guide shoes with lubricators. |
Shaft type | Wall mounted. Guidance for specification option: Standard. Requires a lifting beam at top and scaffolding. Lower lift costs, higher building costs due to construction of load-bearing wall, smaller shaft size. FX structure supported. Guidance for specification option: Can be installed almost anywhere. Offers reduced construction cost, higher lift cost and a slightly larger shaft size (optional for 6, 8 and 13 stretcher person lifts, not suitable for 13 person square). Manufacturer guidanceHeadroom: 3400–4000 mm. Pit depth: 1100–1500 mm. |
Car size / Capacity (w x d) | 6 person (450 kg)/ 1000 x 1300 mm. 8 person (630 kg)/ 1100 x 1400 mm. 13 person stretcher (1000 kg)/ 1400 x 2100 mm. 13 person square (1000 kg)/ 1400 x 1600 mm. 17 person (1250 kg)/ 1950 x 1400 mm. Manufacturer guidanceCar height: 2100 mm. |
Doors | Telescopic, open left (stainless steel finish). Guidance for specification option: Two panels. Telescopic, open left (primed). Guidance for specification option: RAL 7044 silk grey. Two panels. Telescopic, open right (stainless steel finish). Guidance for specification option: Two panels. Telescopic, open right (primed). Guidance for specification option: RAL 7044 silk grey. Two panels. Centre opening, two panels (stainless steel finish). Manufacturer guidanceFrame and sills to match. |
Clear opening | Guidance for specification option: Not all widths are available for all capacities and openings; consult technical literature for exact details and insert requirements. |
Ceiling | Mirror stainless steel. Guidance for specification option: Standard. Manufacturer guidanceA variety of cabin finishes are available for the walls, floors and ceilings please refer to Stannah literature for details. Special and custom finishes are also available - consult manufacturer. |
Lighting | H80 lighting: L40. Guidance for specification option: Standard. H80 lighting: L24. H80 lighting: L21. H80 lighting: L90 (fixed size 600 x 600 mm). H80 lighting: L95 (fixed size 600 x 600 mm). Manufacturer guidanceConsult manufacturer's literature for illustrations. |
Walls | Vinyl skin plate, K01 White. Guidance for specification option: Standard. Vinyl skin plate, K04 Night Black. Guidance for specification option: Standard. Vinyl skin plate, K10 Atlantic Blue. Guidance for specification option: Standard. Vinyl skin plate, K11 Techno Grey. Guidance for specification option: Standard. Vinyl skin plate, K17 Nature Beige. Guidance for specification option: Standard. Manufacturer guidanceA variety of cabin finishes are available for the walls, floors and ceilings please refer to Stannah literature for details. Special and custom finishes are also available - consult manufacturer. |
Flooring | Vinyl, R59 Vinyl Stone Grey Concrete. Vinyl, R61 Vinyl Stone Black Concrete. Vinyl rubber, R74 Classic timber. Vinyl rubber R75 Greywashed timber. Antibacterial vinyl R16 Antibacterial dolphin. Manufacturer guidanceA variety of cabin finishes are available for the walls, floors and ceilings please refer to Stannah literature for details. Special and custom finishes are also available - consult manufacturer. |
Handrail | End-mounted: P13X12 Mirror stainless steel with rounded ends. Guidance for specification option: Standard; EN 81-70 compliant. End-mounted P13E04 Black stainless steel with rounded ends. Guidance for specification option: EN 81-70 compliant. Buttress-mounted P12X12 Mirror stainless steel with rounded ends. Buttress-mounted P12E04 Black stainless steel with rounded ends. Not required. |
Panel configuration | Half height, Supra X02. Half height, Supra X12. Half height, Supra X13. Half height, Supra X24. Half height, Supra X25. |
Control panel finish | Stainless steel, X02 SB Finish Steel. Guidance for specification option: Standard; Scotch-Brite™. Stainless steel, X12 Mirror Finish Steel. Stainless steel, X13 Linen. Stainless steel, X25 Golden Shine. Colour, AC2 Red. Manufacturer guidanceStainless steel AISI 304, except X02. Frame material: Aluminium coloured black (AL04). |
Landing display | LCD-070E 7” display. Guidance for specification option: Standard. TFT-070E 7” display. LCD-043 4.3” display. 639 2.3” display. VS=LCD 2.3” display. |
Mirror | Half height mirror (full width). Guidance for specification option: Fitted as standard. Narrow mirror. Full height narrow mirror. Guidance for specification option: Not EN 81-70 compliant. Full mirror with band. Full mirror. Guidance for specification option: Not EN 81-70 compliant. |
Contains Red List materials | No |
Country of material origin | Spain |
Country of product manufacture | Spain |
Recyclability | 95 |
Peabody Nods for Stannah Passenger Lifts in St John’s Hill Social Housing Regeneration
Emergency Evacuation Passenger Lift Rebuilds Access in Restoration of the Chapel, Royal Victoria Country Park
“Oyez! Stannah brings modern access to historic town hall!”
Stannah Lifts Access In Award-winning Affordable Housing Scheme
Stannah Passenger Lift for Hospice Extension
Stannah Passenger Lifts Up Access in Multi Award-winning Listed Conversion
The ‘best small building in London’ gets two Stannah Xtralifts