Verified by manufacturer 3 months ago
EPD
Certificate type
Reactive fire protection for steel constructions.
Suitable as reactive fire protection for structural steel.
A two-component, solvent-free, amine-cured, 100% solid epoxy intumescent coating for fire protection of structural steel exposed to cellulosic fire.
The product can be used as a mid-coat or finish coat in atmospheric environments and is suitable on approved primers on carbon steel substrates.
Features and benefits:
Color | Grey Guidance for specification option: Light grey after mixing Comp A and Comp B. |
Material | Epoxy resin |
Shape | Formless |
Uniclass | |
CAWS | G10/630 Galvanizing plus site-applied G10/635 Thermally sprayed zinc coating plus site-applied G10/640 Shop painting G10/650 Site painting G10/660 Shop plus site painting M60/175 Protective coating M61/110 On-site coating to primed steel M61/115 On-site coating to galvanized steel M61/120 On-site coating to existing steel M61/140 On-site overcoating to existing steel M61/150 Off-site coating to unprimed steel M61/160 Off-site coating to primed steel M61/170 Off-site coating to galvanized steel |
Composition | A two-component, solvent-free, amine-cured, 100% solid epoxy intumescent coating. |
Colour | Light grey.Guidance for specification option: Light grey after mixing Comp A and Comp B. |
Capacity | 16 L. 50 L. 520 L. |
Material | Epoxy resin |
Certified
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 2 | |
- | 2 |