Swimming Pool Packaged Plate Heat Exchangers - GPPHSWIM4 - Packaged Plate Heat Exchanger

Verified by manufacturer 4 months ago

GPPH45LSWIM - 47 kW

Virdis Energy Ltd Variant:

Swimming pool plate heat exchanger (PHE) with four port control valve.

Jump to:
0333 567 1121 Website

Application

Particularly suitable for use in systems with varying heat loads.

Description

The GPPHSWIM4XX series of packaged swimming pool heat exchangers are available with outputs ranging from 47 kW to 649 kW, when fed with primary water at 82°C. They are designed to operate up to a maximum operating temperature of 110°C. The units are units are designed to provide swimming pool heating on a bypass arrangement of the main filtration loop with an imposed resistance of no more than 20 kPa. All of the units are built around an epoxy coated chassis containing the heat exchanger.


Features and benefits:

  • Available with outputs from 47–649 kW.
  • Four port motorised control valves fitted to the primary circuit.
  • The valve is operated by an electronic temperature controller which senses the returning pool water temperature and opens or closes the valve in response.
  • Standard EcoFlow controller.
  • 82° primary input.
  • Low water content and low thermal inertia.
  • A bypass is not necessary - the fourth port acts as the bypass under no/ low load situations.
  • Fully assembled and factory wired for ease of installation.
  • The pump is fitted with an integral thermal protection relay.

General information

Color

White

Finish

Coated

Material

Steel

EPDM

Stainless steel

Cast iron

Shape

Rectangle

Length

542 mm

619 mm

Width

383 mm

394 mm

Height

1110 mm

1130 mm

Uniclass

Pr_60_60_38_62 Plate heat exchangersPrimary

CAWS

T90/110 Heating system

T90/110 Heating system

Specification data - Plate heat exchangers

Primary medium

-

Fluid

Hot water.

Flow rate

0.73 L/s.

Inlet temperature

82°C.

Outlet temperature

140°C.

Manufacturer guidance

Maximum primary operating temperature.

Working pressure

0.6 N/mm².

Guidance for specification option:

Minimum primary pump inlet pressure (at 82℃): 2.5 mWG.

Manufacturer guidance

Maximum primary operating pressure.

Secondary medium

-

Fluid

Water.

Flow rate

0.45 L/s.

Manufacturer guidance

Pool flow rate.

Outlet temperature

30℃.

Guidance for specification option:

Secondary outlet design temperature (maximum of 60℃).

Output

47 kW.

Material

-

Plates

Stainless steel.

Guidance for specification option:

316 grade.

Gaskets

EPDM.

Plate material/ colour

Epoxy coated steel 25 mm thick (rear chassis plate - stationary).
Epoxy coated steel 20 mm thick (front chassis plate - moveable).

Bolts

16 mm carbon steel.

Manufacturer guidance

Retaining bolts material.

Control valve

4-Port.

Guidance for specification option:

Cast iron, PN6.

Manufacturer guidance

Primary control valve.

Pump

UPS 40.80F, single phase, 250 W.

UPS 50.60/4, single phase, 430 W.

Manufacturer guidance

Primary pump.

Actuator

230 V, motor open/close.

Manufacturer guidance

Primary control valve actuator.

Control

Standard EcoFlow controller.

Control panel

Polycarbonate enclosure.

Manufacturer guidance

Control panel material.

Power supply

230 V, Single Phase, 50 Hz.

Dimensions

542 x 383 x 1110 mm.

Weight

150 kg.

Accessories

Not required.

Duplex unit.

Literature

VIRDIS GPPH4/3XXSWIM (47-1013KW)

VIRDIS GPPH4/3XXSWIM (47-1013KW)

Similar products from Virdis Energy Ltd

Brazed Packaged PHE with Thermal Store - 70°C - Plate Heat Exchanger with Thermal Store

Brazed Packaged PHE with Thermal Store - 70°C - Plate Heat Exchanger with Thermal Store

Brazed Packaged PHE with Thermal Store - 80°C - Plate Heat Exchanger with Thermal Store

Brazed Packaged PHE with Thermal Store - 80°C - Plate Heat Exchanger with Thermal Store

Packaged Plate Heat Exchangers - GPPH2 (50–1000KW) - Packaged Plate Heat Exchanger

Packaged Plate Heat Exchangers - GPPH2 (50–1000KW) - Packaged Plate Heat Exchanger

Packaged Plate Heat Exchangers - GPPH3[05-29] 40/80 (51–416KW) - Packaged Plate Heat Exchanger

Packaged Plate Heat Exchangers - GPPH3[05-29] 40/80 (51–416KW) - Packaged Plate Heat Exchanger

Packaged Plate Heat Exchangers - GPPH3[21-45] 40/120 (360–632KW) - Packaged Plate Heat Exchanger

Packaged Plate Heat Exchangers - GPPH3[21-45] 40/120 (360–632KW) - Packaged Plate Heat Exchanger

Packaged Plate Heat Exchangers - GPPH3[22-74] 50/120 (517-1120KW) - Packaged Plate Heat Exchanger

Packaged Plate Heat Exchangers - GPPH3[22-74] 50/120 (517-1120KW) - Packaged Plate Heat Exchanger

Packaged Plate Heat Exchangers - GPPH4[05-27] – 40/80 (45-320KW) - Packaged Plate Heat Exchanger

Packaged Plate Heat Exchangers - GPPH4[05-27] – 40/80 (45-320KW) - Packaged Plate Heat Exchanger

Packaged Plate Heat Exchangers - GPPH4[23-59] – 50/120 (401-888KW) - Packaged Plate Heat Exchanger

Packaged Plate Heat Exchangers - GPPH4[23-59] – 50/120 (401-888KW) - Packaged Plate Heat Exchanger