NBS Source
I'm a manufacturer
Compare variants

Thermally broken steel fire-resistant door - Janisol 2

Verified by manufacturer 3 days ago

Janisol 2 Single Leaf Inward Opening

Schueco UK Ltd Variant:

Thermally broken steel profile series for fire-resistant doors and glass walls.

Jump to:
+44 (0)1908 282111 Website

Application

Suitable for fire-resistant doors and glass walls.

Description

Steel profile series with a basic depth of 60 mm and the safety features of a fire protection system for flush-fitted single and double-leaf doors, fire-resistant glazing, and doors in glass walls.


Features and benefits:

  • Butt joint glazing up to an element height of 3670 mm offers maximum, storey-high transparency.
  • Maximum transparency through fire protection glazing that can be angled in the floor plan and the possibility of a continuous skylight.
  • Highest mechanical strength and fatigue resistance for doors in public areas.
  • Undisturbed appearance due to concealed hinges.
  • Door closers and drivers.
  • Same view widths also for element couplings.


Standards:

  • EN 14351-1.
  • EN 14024.
  • EN 1192 (Class 4).
  • EN 16005.
  • EN 12210.
  • EN 12208.
  • EN ISO 10140.
  • EN ISO 10077-2.
  • EN 12207.
  • EN 1192.
  • EN 12219.
  • EN 1627.
  • EN 1522.
  • EN 14024.
  • EN 12400.
  • EN 12217.

General information

Color

-

Manufacturer guidance

Almost unlimited choice of colours, consult manufacturer for options.

Finish

Painted

Guidance for specification option:

Wet paint coating.

Powder-coated

Material

Steel

Width

Bespoke

Height

Bespoke

Uniclass

Pr_30_59_24_52 Carbon steel doorsetsPrimary

CAWS

L20/480 Doorsets

L20/55 Doorsets

Specification data - Carbon steel doorsets

Standard

To EN 14351-1.

Third-party certification

EPD; CE Marking.

Configuration

Single leaf inward opening.

Doorset size

Guidance for specification option:

Consult manufacturer for options and insert requirements.

  • Maximum weight: 230 kg.
  • Minimum face width: 107.5 mm.

Performance

-

Fire resistance

-

Insulation

EI30.

Smoke leakage

Manufacturer's standard.

Acoustic performance

-

Manufacturer guidance

To EN ISO 10140; insert requirements, up to 43 dB(A).

Strength and durability

To BS EN 1192, Class 4.

Guidance for specification option:

Proof of durability:

  • 200 000 cycles in accordance with DIN EN 12400,
  • 1 000 000 cycles in accordance with DIN EN 12400.

Thermal

-

Manufacturer guidance

Consult manufacturer for options and insert requirements.

Frame Uf: 2.2 W/m²K.

Intruder resistance

-

Minimum requirement

-

Manufacturer guidance

Insert requirements, up to RC3.

Bullet resistance

To BS EN 1522, Class FB6.

Frame

-

Material

Steel.

Finish

-

Coating

Powder-coated.

Painted.

Guidance for specification option:

Wet paint coating.

Colour

Guidance for specification option:

Almost unlimited choice of colours, consult manufacturer.

Door leaf

-

Thickness

60 mm.

Guidance for specification option:

Basic depth, flush-fitted on the inside and outside.

Core

Manufacturer's standard.

Panel details

Manufacturer's standard.

Material

Steel.

Glazing

-

Type

-

Manufacturer guidance

Insert requirements.

  • Maximum panel thickness: 39 mm.
  • Maximum panel size: 2000 x 2840 mm.


Glazing installed by means of dry or wet glazing.

Manifestation

-

Manufacturer guidance

Consult manufacturer for options and insert requirements or omit.

Beading

-

Material

Steel.

Finish

-

Coating

As Frame.

Painted.

Guidance for specification option:

Wet paint coating.

Powder-coated.

Texture

Manufacturer's standard.

External colour

As Frame.

Other.

Guidance for specification option:

Consult manufacturer for options and insert requirements.

Internal colour

As External.

Other.

Guidance for specification option:

Consult manufacturer for options and insert requirements.

Film thickness (minimum)

Manufacturer's standard.

Door accessories

-

Manufacturer guidance

Consult manufacturer for options and insert requirements or omit.

Hardware

-

Manufacturer guidance

Consult manufacturer for options and insert requirements.

Accessories

-

Manufacturer guidance

Consult manufacturer for options and insert requirements or omit.

Watertightness

To EN 12208, 4A.

Air permeability

To EN 12207, Class 4.

Burglar resistance

To EN 1627, Class 3.

Impact resistance

To 12217, Class 1.

Temperature resistance

2(x)C.

Manufacturer guidance

Resistance to change in temperature.

Sustainability data

Country of material origin

United Kingdom

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

23 %

BIM objects

Platform Compatible Version
Revit
-

1