NBS Source
I'm a manufacturer
Compare variants

Thermally Broken Steel Fire-resistant Door - Janisol C4

Verified by manufacturer 13 days ago

Janisol C4 Single Leaf Inward Opening

Schueco UK Ltd Variant:

Fire door for demanding security requirements.

Jump to:
+44 (0)1908 282111 Website

Application

Suitable as a fire door.

Description

A steel profile series with a basic depth of 70 mm offering the safety features of a fire protection system. Fire-resistant infill panels achieve resistance times of up to 90 minutes in accordance with DIN 4102, improve the security requirements and are easy to install due to the cable ducts supplied as standard in the Janisol C4 profile.


Features and benefits:

  • Single and double-leaf fire protection barriers with toplight and sidelights.
  • Clear opening heights of up to 2500 mm.
  • Clear opening widths: up to 1400 mm for single-leaf and up to 2600 mm for double-leaf.
  •  Maximum height of fixed glazing 4000 mm.
  •  Same face widths as the fire and smoke protection series.
  •  Glazing on one side and centre glazing.
  •  Units connected using 25 mm chamber profiles.
  •  Same range of fittings as Janisol 2.
  •  T90 approved since May 2008.
  • Also available in stainless steel; consult manufacturer for details.


Standards:

  • EN 1634.
  • EN 12210.
  • EN 12208.
  • EN ISO 10140.
  • EN ISO 10077-2.
  • EN 12207.
  • EN 1192.
  • EN 1191.
  • EN 1603.
  • EN 12217.
  • EN 179.
  • EN 1125.
  • DIN 18040.
  • EN 1634-1.
  • EN 13501-2.
  • EN 1634-3.
  • EN 13501-2.
  • EN 16034.
  • EN 13501-2.
  • EN 16034.

General information

Finish

Galvanized

Guidance for specification option:

Strip galvanized steel profiles.

Natural

Guidance for specification option:

Uncoated.

Powder-coated

Enamelled

Guidance for specification option:

Stove enamelled.

Material

Steel

Width

Bespoke

Height

Bespoke

Uniclass

Pr_30_59_24_52 Carbon steel doorsetsPrimary

CAWS

L20/480 Doorsets

L20/55 Doorsets

Specification data - Carbon steel doorsets

Standard

To EN 16034.

Third-party certification

EPD; CE Marking.

Configuration

Single leaf inward opening.

Doorset size

-

Manufacturer guidance

Consult manufacturer for options and insert requirements.

Maximum weight: 350 kg.

Performance

-

Fire resistance

-

Insulation

To EN 13501-2, EI60.

To EN 13501-2, EI90.

Smoke leakage

To EN 1634-3, S200.

Acoustic performance

-

Manufacturer guidance

To BS EN ISO 10140-2. Insert requirements, up to 43 dB.

Strength and durability

To BS EN 1192, Class 4; to EN 1191, Class 6.

Guidance for specification option:

Durability: Up to one million cycles.

Thermal

-

Manufacturer guidance

Consult manufacturer for details and insert requirements.

  • Frame Uf: ≥3.0 W/m²K.
  • Door Ud: ≥1.9 W/m²K.
  • Window Uw: ≥1.8 W/m²K.

Frame

-

Material

Steel.

Finish

-

Coating

Uncoated.

Strip-galvanized.

Guidance for specification option:

Strip galvanised steel profiles.

Powder coated.

Stove enamelled.

Colour

-

Manufacturer guidance

Insert requirements or omit as applicable for Coating specified.

Installation fasteners

-

Manufacturer guidance

Consult manufacturer for details and insert requirements.

Frame accessories

-

Manufacturer guidance

Consult manufacturer for details and insert requirements or omit.

Door leaf

-

Thickness

70 mm.

Core

Manufacturer's standard.

Guidance for specification option:

To achieve specified performance.

Panel details

Manufacturer's standard.

Material

Steel.

Glazing

-

Type

-

Manufacturer guidance

Insert requirements, up to 49 mm thick.

Maximum glass panel size: 1400 x 2500 mm.

Manifestation

-

Manufacturer guidance

Consult manufacturer for options and insert requirements or omit.

Finish

-

Coating

As Frame.

Texture

Manufacturer's standard.

External colour

As Frame.

Internal colour

As External.

Film thickness (minimum)

Manufacturer's standard.

Door accessories

-

Manufacturer guidance

Consult manufacturer for options and insert requirements or omit.

Hardware

-

Manufacturer guidance

Consult manufacturer for options and insert requirements.

Architraves

-

Material

Steel.

Finish

As Frame.

Accessories

-

Manufacturer guidance

Consult manufacturer for options and insert requirements or omit.

Resistance to wind load

To EN 12210, Class 4.

Watertightness

To EN 12208, 4A.

Air permeability

To EN 12207, Class 4.

Operating forces

To EN 12217, Class 2.

Sustainability data

Country of material origin

United Kingdom

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

23 %

BIM objects

Platform Compatible Version
Revit
-

1

Similar products from Schueco UK Ltd

Non-insulated Steel door - Economy 50

Non-insulated Steel door - Economy 50

Non-insulated Steel Door - Economy 60

Non-insulated Steel Door - Economy 60

Thermally broken steel fire-resistant door - Janisol 2

Thermally broken steel fire-resistant door - Janisol 2

Thermally insulated steel door - Janisol

Thermally insulated steel door - Janisol