Verified by manufacturer 3 days ago
BBA Agrément Certificate
Certificate type
Single layer, reinforced SBS modified bitumen membrane, warm roof covering.
Suitable for use in refurbishment or new build projects where used as part of a warm roof construction.
A mechanically fixed or adhered, mineral finished bitumen single layer roof waterproofing system. The 120mm side lap facilitates mechanical fixings which can be hot-air welded to form a waterproof seal.
Features and benefits:
Color | Black |
Finish | Mineral |
Material | Bitumen |
Shape | Other |
Length | 7500 mm |
Width | 1000 mm |
Warranty description | 20 year |
Uniclass | |
CAWS | J41/115 Single-layer reinforced bitumen membrane warm deck roof covering J41/135 Single-layer reinforced bitumen membrane cold deck roof covering |
Classification data | |
Preparation | |
Horizontal work | Icopal SA Primer. Guidance for specification option: Quick drying primer for self-adhesive membranes. |
Skirtings and vertical work | Icopal SA Primer. Guidance for specification option: Quick drying primer for self-adhesive membranes. |
Air and vapour control layer | |
Type | Not required. TorchSafe T.A. VCL - Sand. Guidance for specification option: Heat-activated self-adhesive bituminous vapour control layer. |
Attachment | Self-adhered. |
Insulation | |
Type | Thermazone Roofboard. |
Fixing | Adhered. |
Waterproof covering | |
Top layer | |
Type | TorchSafe MA Mineral Capsheet. Guidance for specification option: Single-layer membrane. |
Attachment | Adhered. Mechanically fastened. |
Detail work | |
Flashings | TorchSafe TA Detailing Underlay and TorchSafe TA Mineral Capsheet. Guidance for specification option: Omit if not applicable. |
Skirtings and upstands | TorchSafe TA Detailing Underlay and TorchSafe TA Mineral Capsheet. Guidance for specification option: Omit if not applicable. |
Welted drips | TorchSafe TA Detailing Underlay and TorchSafe TA Mineral Capsheet. Guidance for specification option: Omit if not applicable. |
System accessories | None. Icopal GRP Edge Trims. Icopal Roofgard Outlet. Icopal Roofgard Parapet Outlet. Icopal Roofgard Cable and Tube Duct. Icopal Roofgard Cowled Telescopic Vent. Icopal Roofgard Lightning Conductor Pads. |
Colour | Charcoal. |
Preparation | Not required. Anderson HT180 Nailed Layer. Guidance for specification option: For timber boarded decks. Anderson HT125 Taping Strip. Guidance for specification option: For joints in ply/ OSB/ three decks. |
Underlay | Icopal T.A. Detailing Underlay. |
Material | Bitumen |
Power Elastomeric 250 Sand
Profiles XL Firesmart Plus System - Warm Roof / Safe2Torch / Full Bond / Adhered / MW
Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Full Bond / Adhered / PIR - System Number 1
Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Full Bond / Mech Fixed / MW
Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Full Bond / Mech Fixed / PIR - System Number 5
Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Partial Bond / Adhered / MW - System Number 4
Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Partial Bond / Adhered / PIR - System Number 2
Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Partial Bond / Heated / MW - System Number 12
Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Partial Bond / Heated / PIR - System Number 11
Profiles XL FireSmart Plus System - Warm Roof / Safe2Torch / Partial Bond / Heated / PIR - System Number 6