Verified by manufacturer 2 months ago
Steel insulated fireproof panels.
The range of applications for the horizontal joint façade system is extremely wide. They are suitable for business, commercial, leisure, trade and industrial buildings.
The basic horizontal façade system consists of Trimoterm FTV panels of standard modular widths 1000 and 1200 mm.
The horizontal façade system has excellent technical properties, a long life span and allows creative freedom in building envelope design. The system of Trimoterm fireproof panels ensures high fire resistance, excellent thermal and sound insulation. The panels are used primarily as a facade, partition walls, fire walls and ceilings, or even as a back up panels for variety of rainscreen façade systems. CE marked, LPCB, FM certified.
Panels Composition
Trimoterm FTV fireproof panels consist of two shallow profiled, coated sheet faces in thickneses of 0.5 to 0.7 mm. The steel sheet is bonded to the panel core made of non-combustible mineral wool lamellas of class A1 (EN 13501-1). All three layers make a solid panel in a thickness of 50 - 240 mm. Standard width of the panels are 1000 and 1200 mm. Non standard panel width of 600 -1200 mm can be made by a special request. A protective PVC film is applied to the panel surface to protect it during production handling and transport. Panels can be manufactured up to 14 m long.
Finish | Galvanized Guidance for specification option: Hot galvanized (net 275 g/m² ) in compliance with EN 10346, and additionally protected by organic coating in accordance with the coil-coating process (DIN EN 10169/1) |
Material | Steel Mineral fibre Mineral wool |
Shape | Rectangle Square |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | Ten year |
Uniclass | |
CAWS | H43/120 Metal insulating sandwich panel H43/10 Metal insulating sandwich panel |
Panels | Factory-assembled insulating sandwich panels. |
Panel construction | |
Panel external face | |
Material | Steel. |
Profile | Micro-lined profile (M).Micro-lined profile (M3).S - profile (standard profile).Smooth profile (G).V - profile (V).V - profile (V2).V - profile (V6)Guidance for specification option: 1200 mm width. |
Panel internal face | |
Material | Steel. |
Profile | Micro-lined profile (M2).S - profile (standard profile).Smooth profile (G).V - profile (V).V - profile (V2).V - profile (V6)Guidance for specification option: 1200 mm width. |
Core insulation | Non-combustible mineral wool lamella. |
Panel dimensions | |
Length | Manufacturer guidance14 m (maximum). Insert requirements. |
Cover width | 1000 mm.1200 mm. |
Thickness | 50 mm.60 mm.80 mm.100 mm.120 mm.133 mm.150 mm.172 mm.200 mm.240 mm. |
Finish as delivered | |
Outer skin | |
Material | SP.PVDF.PVC(P).PVC(F).PUR.Manufacturer guidanceFor corrosion protection details consult technical literature. |
Fire performance | |
Reaction to fire | |
Core | Class A1 (EN 13501-1). |
Fire resistance | Up to EI 240. |
Thermal transmittance (U-Value) | ≥0.15 W/m²K. |
Sound insulation | ≤32 dB (-1;-2). |
Water permeability | Class A (1200 Pa). |
Air permeability | n=1.5: C=0.00005. |
Burglary resistance (to BS EN 1627) | RC3. |
Country of material origin | Slovenia |
Country of product manufacture | Slovenia |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 60 kg CO₂ eq/m² |
Recyclability | 99% Guidance for specification option: Up to 99%. |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 40 % Guidance for specification option: Up to. |