NBS Source
I'm a manufacturer

TWR/TLR Pitched Roof Sun Tunnel, Rigid Tube

Verified by manufacturer 6 months ago

VELUX Company Ltd

Pitched roof sun tunnel with roof module, rigid pipe and ceiling diffuser.

Jump to:
+44 (0)1592 778873 Website

Application

Suitable for windowless bathrooms, hallways and cupboards. Roof pitches from 15–60°.

Description

Features and benefits:

  • Complete installation kits with all necessary components for both exterior and interior connections.
  • Rooflight has toughened glazing with clear and clean coating to keep glass cleaner for longer.
  • Frosted two-layer light diffuser with EdgeGlow.
  • Integral flashing suitable for slate or tiles.
  • Rigid tunnel is ideal for distances between roof and ceiling from 0.9–1.7 m (up to 6 m with extension sections).

General information

Color

Black

Guidance for specification option:

TWR Black Frame and Sash

Grey

Guidance for specification option:

TLR Grey Frame and Sash

Material

Polyurethane

Plastic

Shape

Other

Guidance for specification option:

Pitched roof and tubular tunnel.

Size

Guidance for specification option:

Tunnel is suitable for distances between roof and ceiling from 0.9–1.7 m (up to 6 m with extension sections)

Length

1700 mm

Width

370 mm

460 mm

Height

370 mm

460 mm

Warranty description

Ten year

Uniclass

Pr_30_59_72_21 Daylight pipesPrimary

CAWS

L10/495 Daylight pipe

Product range

Sun Tunnels

Specification data - Daylight pipes

Material

Polyurethane.

Plastic.

Diameter

10", 14".

Guidance for specification option:

Depending on rooflight.

Length

Guidance for specification option:

Between 0.9m and 6m (with extensions) - 1.7 m supplied.

Accessories

None.

ZTR 0K10 0062.

Guidance for specification option:

620 mm rigid extension section for 10" diameter tunnel.

ZTR 0K14 0062.

Guidance for specification option:

620 mm rigid extension section for 14" diameter tunnel.

ZTR 0K14 0124.

Guidance for specification option:

1200 mm rigid extension section for 14" diameter tunnel.

ZTL 014.

Guidance for specification option:

Low energy light kit (requires mains connection)

Execution

Installation of daylight pipes.

Product Reference

TWR 0K10 2010

Guidance for specification option:

10" diameter rigid tunnel for installation into tiles up to 120 mm profile.

TLR 0K10 2010

Guidance for specification option:

10" diameter rigid tunnel for installation into slate up to 8 mm thick.

TWR 0K14 2010

Guidance for specification option:

14" diameter rigid tunnel for installation into tiles up to 120 mm profile.

TLR 0K14 2010

Guidance for specification option:

14" diameter rigid tunnel for installation into slate up to 8 mm thick.

Roof pitch

Guidance for specification option:

Insert requirements.